메뉴 건너뛰기




Volumn 13, Issue 6, 1997, Pages 451-462

Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound

Author keywords

3 D reconstruction; Biplane angiography; Catheter twist; Coronary arteries; Data fusion; Intravascular ultrasound; Pullback imaging

Indexed keywords

ANGIOCARDIOGRAPHY; ANIMAL MODEL; ARTICLE; CADAVER; CARDIOVASCULAR DISEASE; CATHETER; COMPUTER SIMULATION; CORONARY ARTERY DISEASE; DIAGNOSTIC IMAGING; IMAGE RECONSTRUCTION; INTRAVASCULAR ULTRASOUND; NONHUMAN; SWINE; THREE DIMENSIONAL IMAGING;

EID: 0030700724     PISSN: 01679899     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1005843222820     Document Type: Article
Times cited : (45)

References (23)
  • 1
    • 0017348841 scopus 로고
    • Quantitative coronary arteriography. Estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation
    • Brown BG, Bolson E, Frimer M, Dodge H. Quantitative coronary arteriography. Estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation. Circulation 1977; 55: 329-37.
    • (1977) Circulation , vol.55 , pp. 329-337
    • Brown, B.G.1    Bolson, E.2    Frimer, M.3    Dodge, H.4
  • 4
    • 0029264263 scopus 로고
    • Robust simultaneous detection of coronary borders in complex images
    • Sonka M, Winniford MD, Collins SM. Robust simultaneous detection of coronary borders in complex images. IEEE Trans Med Imag 1995; 14(1): 151-61.
    • (1995) IEEE Trans Med Imag , vol.14 , Issue.1 , pp. 151-161
    • Sonka, M.1    Winniford, M.D.2    Collins, S.M.3
  • 5
    • 12844263863 scopus 로고
    • Semi-automated boundary detection for intravascular ultrasound
    • 1992 Oct 11-14; Durham (NC). Los Alamitos (CA): IEEE
    • Herrington DM, Johnson T, Santago P, Snyder, WE. Semi-automated boundary detection for intravascular ultrasound. In: Proc. Conf. Computers in Cardiology; 1992 Oct 11-14; Durham (NC). Los Alamitos (CA): IEEE 1992: 103-6.
    • (1992) Proc. Conf. Computers in Cardiology , pp. 103-106
    • Herrington, D.M.1    Johnson, T.2    Santago, P.3    Snyder, W.E.4
  • 8
    • 0023224633 scopus 로고
    • Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography
    • Parker DL, Pope DL, van Bree R, Marshall H. Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography. Comp Biomed Res 1987; 20: 166-85.
    • (1987) Comp Biomed Res , vol.20 , pp. 166-185
    • Parker, D.L.1    Pope, D.L.2    Van Bree, R.3    Marshall, H.4
  • 9
    • 0024068825 scopus 로고
    • Estimating the 3-D skeletons and transverse areas of coronary arteries from biplane angiograms
    • Kitamura K, Tobis JM, Sklansky J. Estimating the 3-D skeletons and transverse areas of coronary arteries from biplane angiograms. IEEE Trans Med Imag 1988; 7(3): 173-87.
    • (1988) IEEE Trans Med Imag , vol.7 , Issue.3 , pp. 173-187
    • Kitamura, K.1    Tobis, J.M.2    Sklansky, J.3
  • 11
    • 0029327157 scopus 로고
    • Assessment of diffuse artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms
    • Wahle A, Wellnhofer E, Mugaragu I, Sauer HU, Oswald H, Fleck E. Assessment of diffuse artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms. IEEE Trans Med Imag 1995; 14(2): 230-41.
    • (1995) IEEE Trans Med Imag , vol.14 , Issue.2 , pp. 230-241
    • Wahle, A.1    Wellnhofer, E.2    Mugaragu, I.3    Sauer, H.U.4    Oswald, H.5    Fleck, E.6
  • 12
    • 84941604931 scopus 로고
    • Reconstructing the cross sections of coronary arteries from biplane angiograms
    • Van Tran L, Bahn RC, Sklansky J. Reconstructing the cross sections of coronary arteries from biplane angiograms. IEEE Trans Med Imag 1992; 11(4): 517-29.
    • (1992) IEEE Trans Med Imag , vol.11 , Issue.4 , pp. 517-529
    • Van Tran, L.1    Bahn, R.C.2    Sklansky, J.3
  • 13
    • 0028105943 scopus 로고
    • Three-dimensional reconstruction of intracoronary ultrasound images: Rationale, approaches, problems, and directions
    • Roelandt JRTC, Di Mario C, Pandian NG, Li W, Keane D, Slager CJ, et al. Three-dimensional reconstruction of intracoronary ultrasound images: rationale, approaches, problems, and directions. Circulation 1994; 90(2): 1044-55.
    • (1994) Circulation , vol.90 , Issue.2 , pp. 1044-1055
    • Roelandt, J.R.T.C.1    Di Mario, C.2    Pandian, N.G.3    Li, W.4    Keane, D.5    Slager, C.J.6
  • 14
    • 0029493434 scopus 로고
    • ANGUS: A new approach to three-dimensional reconstruction of coronary vessels by combined use of angiography and intravascular ultrasound
    • 1995 Sep 10-13; Vienna. Piscataway (NJ): IEEE
    • Laban M, Oomen JA, Slager CJ, Wentzel JJ, Krams R, Schuurbiers JHC, et al. ANGUS: a new approach to three-dimensional reconstruction of coronary vessels by combined use of angiography and intravascular ultrasound. In: Proc Conf Computers in Cardiology; 1995 Sep 10-13; Vienna. Piscataway (NJ): IEEE 1995: 325-8.
    • (1995) Proc Conf Computers in Cardiology , pp. 325-328
    • Laban, M.1    Oomen, J.A.2    Slager, C.J.3    Wentzel, J.J.4    Krams, R.5    Schuurbiers, J.H.C.6
  • 15
    • 9044235783 scopus 로고    scopus 로고
    • Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions
    • Evans JL, Ng KH, Wiet SG, Vonesh MJ, Burns WB, Radvany MG, et al. Accurate three-dimensional reconstruction of intravascular ultrasound data - spatially correct three-dimensional reconstructions. Circulation 1996; 93(3): 567-76.
    • (1996) Circulation , vol.93 , Issue.3 , pp. 567-576
    • Evans, J.L.1    Ng, K.H.2    Wiet, S.G.3    Vonesh, M.J.4    Burns, W.B.5    Radvany, M.G.6
  • 16
    • 0029702029 scopus 로고    scopus 로고
    • Semi-automated segmentation and 3-D reconstruction of coronary trees: Biplane angiography and intravascular ultrasound data fusion
    • Hoffman EA, editor. Physiology and Function from Multidimensional Images. 1996 Feb 11-15; Newport Beach (CA). Bellingham (WA): SPIE
    • Prause GPM, DeJong SC, McKay CR, Sonka M. Semi-automated segmentation and 3-D reconstruction of coronary trees: biplane angiography and intravascular ultrasound data fusion. In: Hoffman EA, editor. Physiology and Function from Multidimensional Images. Proc Conf Medical Imaging; 1996 Feb 11-15; Newport Beach (CA). Bellingham (WA): SPIE 1996; 2709: 82-92.
    • (1996) Proc Conf Medical Imaging , vol.2709 , pp. 82-92
    • Prause, G.P.M.1    DeJong, S.C.2    McKay, C.R.3    Sonka, M.4
  • 17
    • 0030396721 scopus 로고    scopus 로고
    • Fusion of intravascular ultrasound and biplane angiography for three-dimensional reconstruction of coronary arteries
    • 1996 Sep 8-11; Indianapolis (IN). Piscataway (NJ): IEEE
    • Shekhar R, Cothren RM, Vince DG, Cornhill JF. Fusion of intravascular ultrasound and biplane angiography for three-dimensional reconstruction of coronary arteries. In: Proc Conf Computers in Cardiology; 1996 Sep 8-11; Indianapolis (IN). Piscataway (NJ): IEEE 1996: 5-8.
    • (1996) Proc Conf Computers in Cardiology , pp. 5-8
    • Shekhar, R.1    Cothren, R.M.2    Vince, D.G.3    Cornhill, J.F.4
  • 18
    • 0030417884 scopus 로고    scopus 로고
    • Geometrically correct 3-D reconstruction of coronary wall and plaque: Combining biplane angiography and intravascular ultrasound
    • 1996 Sep 8-11; Indianapolis (IN). Piscataway (NJ): IEEE
    • Prause GPM, DeJong SC, McKay CR, Sonka M. Geometrically correct 3-D reconstruction of coronary wall and plaque: combining biplane angiography and intravascular ultrasound. In: Proc Conf Computers in Cardiology; 1996 Sep 8-11; Indianapolis (IN). Piscataway (NJ): IEEE 1996: 325-8.
    • (1996) Proc Conf Computers in Cardiology , pp. 325-328
    • Prause, G.P.M.1    DeJong, S.C.2    McKay, C.R.3    Sonka, M.4
  • 20
    • 0029750211 scopus 로고    scopus 로고
    • Distortion of intravascular ultrasound images because of nonuniform angular velocity of mechanical type transducers
    • Kimura BJ, Bhargava V, Palinski W, Russo RJ, DeMaria AN. Distortion of intravascular ultrasound images because of nonuniform angular velocity of mechanical type transducers. Am Heart J 1996; 132: 328-36.
    • (1996) Am Heart J , vol.132 , pp. 328-336
    • Kimura, B.J.1    Bhargava, V.2    Palinski, W.3    Russo, R.J.4    Demaria, A.N.5
  • 21
    • 0030393155 scopus 로고    scopus 로고
    • ECG-gated ICUS image acquisition combined with a semi-automated contour detection provides accurate analysis of vessel dimensions
    • 1996 Sep 8-11; Indianapolis (IN). Piscataway (NJ): IEEE
    • Bruining N, von Birgelen C, de Vrey E, Nicosia A, Li W, Prati F, et al. ECG-gated ICUS image acquisition combined with a semi-automated contour detection provides accurate analysis of vessel dimensions. In: Proc Conf Computers in Cardiology; 1996 Sep 8-11; Indianapolis (IN). Piscataway (NJ): IEEE 1996: 53-6.
    • (1996) Proc Conf Computers in Cardiology , pp. 53-56
    • Bruining, N.1    Von Birgelen, C.2    De Vrey, E.3    Nicosia, A.4    Li, W.5    Prati, F.6
  • 23
    • 0030216930 scopus 로고    scopus 로고
    • Binary reconstruction of the heart chambers from biplane angiographic image sequences
    • Prause GPM, Onnasch DGW. Binary reconstruction of the heart chambers from biplane angiographic image sequences. IEEE Trans Med Imag 1996; 15(4): 532-46.
    • (1996) IEEE Trans Med Imag , vol.15 , Issue.4 , pp. 532-546
    • Prause, G.P.M.1    Onnasch, D.G.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.