메뉴 건너뛰기




Volumn 86, Issue 11, 1997, Pages 1246-1252

Comparison of two methods of measurement of whole blood glucose in the neonatal period

Author keywords

Blood glucose; HemoCue; Hypoglycaemia; Reagent strip tests

Indexed keywords

GLUCOSE;

EID: 0030698149     PISSN: 08035253     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1651-2227.1997.tb14855.x     Document Type: Article
Times cited : (13)

References (14)
  • 1
    • 0027284774 scopus 로고
    • Blood glucose and glycated haemoglobin measurements in hospital. Which method?
    • Pickup JC, Crook MA, Tutt P. Blood glucose and glycated haemoglobin measurements in hospital. Which method? Diabet Med 1993; 10: 402-11
    • (1993) Diabet Med , vol.10 , pp. 402-411
    • Pickup, J.C.1    Crook, M.A.2    Tutt, P.3
  • 2
    • 0024848517 scopus 로고
    • HONK. A five year study of neonatal hypoglycaemia in Toa Payah Hospital (1984-1988)
    • Lin MS, HONK. A five year study of neonatal hypoglycaemia in Toa Payah Hospital (1984-1988). J Singapore Paediatr Soc 1989; 31: 116-21
    • (1989) J Singapore Paediatr Soc , vol.31 , pp. 116-121
    • Lin, M.S.1
  • 4
    • 0027463199 scopus 로고
    • An assessment of the effect of huematocrit on the HemoCue blood glucose analyzer
    • Weiner K. An assessment of the effect of huematocrit on the HemoCue blood glucose analyzer. Ann Clin Biochem 1993; 30: 90-3
    • (1993) Ann Clin Biochem , vol.30 , pp. 90-93
    • Weiner, K.1
  • 5
    • 0025215075 scopus 로고
    • Reagent-strip glucose methods and haematocrit
    • Labib M, Digger T, Perks D. Reagent-strip glucose methods and haematocrit (Letter). Lancet 1990; 355: 973-4
    • (1990) Lancet , vol.355 , pp. 973-974
    • Labib, M.1    Digger, T.2    Perks, D.3
  • 6
    • 85176627564 scopus 로고
    • Reagent-strip glucose methods and haematocrit
    • Weiner K, Enoch BA. Reagent-strip glucose methods and haematocrit (Letter). Lancet 1990; 355: 974
    • (1990) Lancet , vol.355 , pp. 974
    • Weiner, K.1    Enoch, B.A.2
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical agreement
    • Bland J, Altman DG. Statistical methods for assessing agreement between two methods of clinical agreement. Lancet 1986; i: 307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.1    Altman, D.G.2
  • 8
    • 0015929050 scopus 로고    scopus 로고
    • Plasma or whole blood glucose?
    • 197
    • Morrison B, Fleck A. Plasma or whole blood glucose? Clin Chim Acta 197; 45: 293-7
    • Clin Chim Acta , vol.45 , pp. 293-297
    • Morrison, B.1    Fleck, A.2
  • 9
  • 10
    • 0028824786 scopus 로고
    • Comparison of two reflectance photometers in the assessment of neonatal hypoglycaemia
    • Kirkham P, Watkins A. Comparison of two reflectance photometers in the assessment of neonatal hypoglycaemia. Arch Dis Child 1995; 73: 170-3
    • (1995) Arch Dis Child , vol.73 , pp. 170-173
    • Kirkham, P.1    Watkins, A.2
  • 11
    • 0028003994 scopus 로고
    • Reliability of glucose measurement using the HemoCue analyser in hypoglycaemia
    • Young RP, Critchley JH, Lou MSW, et al. Reliability of glucose measurement using the HemoCue analyser in hypoglycaemia. Ann Clin Biochem 1994; 31: 573-5
    • (1994) Ann Clin Biochem , vol.31 , pp. 573-575
    • Young, R.P.1    Critchley, J.H.2    Lou, M.S.W.3
  • 14
    • 0026779446 scopus 로고
    • HemoCue, evaluation of a portable photometric system for determining glucose in whole blood
    • Ashworth L, Gibb I, Alberti KGMM. HemoCue, evaluation of a portable photometric system for determining glucose in whole blood. Clin Chem 1992; 38: 1482-97
    • (1992) Clin Chem , vol.38 , pp. 1482-1497
    • Ashworth, L.1    Gibb, I.2    Alberti, K.G.M.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.