메뉴 건너뛰기




Volumn 10, Issue 5, 1997, Pages 263-273

In vivo strain measurements collected using calcium phosphate ceramic-bonded strain gauges

Author keywords

Biomechanics; Bone; Fixation; Hydroxyapatite; Ingrowth hard tissue

Indexed keywords

CALCIUM PHOSPHATE CERAMIC; CYANOACRYLATE; HYDROXYAPATITE;

EID: 0030697097     PISSN: 08941939     EISSN: None     Source Type: Journal    
DOI: 10.3109/08941939709032165     Document Type: Article
Times cited : (17)

References (16)
  • 1
  • 2
    • 0027613586 scopus 로고
    • The development of hydroxyapatite coated strain gauges for long-term in vivo bone loading response measurements
    • Maliniack MM, Szivek JA, DeYoung D. The development of hydroxyapatite coated strain gauges for long-term in vivo bone loading response measurements. J Appl Biomater. 1993;4(2):143-152.
    • (1993) J Appl Biomater , vol.4 , Issue.2 , pp. 143-152
    • Maliniack, M.M.1    Szivek, J.A.2    DeYoung, D.3
  • 3
    • 0030248624 scopus 로고    scopus 로고
    • Evaluation of factors affecting bonding rate of calcium phosphate ceramic coatings for in vivo strain gauge attachment
    • Szivek JA, DeYoung D, Anderson PL. Evaluation of factors affecting bonding rate of calcium phosphate ceramic coatings for in vivo strain gauge attachment. J Biomed Mater Res. 1996;33(3):121-132.
    • (1996) J Biomed Mater Res , vol.33 , Issue.3 , pp. 121-132
    • Szivek, J.A.1    DeYoung, D.2    Anderson, P.L.3
  • 4
    • 0026507026 scopus 로고
    • In vivo strain analysis of the greyhound femoral diaphysis
    • Szivek JA, Johnson EM, Magee FP. In vivo strain analysis of the greyhound femoral diaphysis. J Invest Surg. 1992;5:91-108.
    • (1992) J Invest Surg , vol.5 , pp. 91-108
    • Szivek, J.A.1    Johnson, E.M.2    Magee, F.P.3
  • 6
    • 0020075501 scopus 로고
    • Experimental determination of whole long bone sectional properties
    • Gies AA, Carter DR. Experimental determination of whole long bone sectional properties. J Biomechanics. 1982;15: 297-303.
    • (1982) J Biomechanics , vol.15 , pp. 297-303
    • Gies, A.A.1    Carter, D.R.2
  • 7
    • 0015956006 scopus 로고
    • Mechanical properties of bone as a function of position and orientation
    • Pope MH, Outwater JO. Mechanical properties of bone as a function of position and orientation. J Biomechanics. 1974;7:61-66.
    • (1974) J Biomechanics , vol.7 , pp. 61-66
    • Pope, M.H.1    Outwater, J.O.2
  • 8
    • 0028403921 scopus 로고
    • Symmetry of biomechanical properties of canine femora
    • Kersey RC, Szivek JA, Sacoman DM. Symmetry of biomechanical properties of canine femora. J Appl Biomater. 1994;5(1):99-101.
    • (1994) J Appl Biomater , vol.5 , Issue.1 , pp. 99-101
    • Kersey, R.C.1    Szivek, J.A.2    Sacoman, D.M.3
  • 9
    • 0342788928 scopus 로고
    • Histomorphometric quantitative analysis of bone
    • Sheehan DC, Hrapchak B, eds. St. Louis, MO: Mosby
    • Villanueva AR. Histomorphometric quantitative analysis of bone. In: Sheehan DC, Hrapchak B, eds. Theory and Practice of Histotechnology, pp. 108-117. St. Louis, MO: Mosby; 1980.
    • (1980) Theory and Practice of Histotechnology , pp. 108-117
    • Villanueva, A.R.1
  • 10
    • 84907128648 scopus 로고
    • A polymethylmethacrylate method for large specimens of mineralized bone with implants
    • Emmanual J, Hornbeck C, Bloebaum RD. A polymethylmethacrylate method for large specimens of mineralized bone with implants. Stain Technol. 1987;62:401-410.
    • (1987) Stain Technol , vol.62 , pp. 401-410
    • Emmanual, J.1    Hornbeck, C.2    Bloebaum, R.D.3
  • 11
    • 84907130837 scopus 로고
    • A versatile new mineralized bone strain for simultaneous assessment of tetracycline and osteoid seams
    • Villanueva AR, Lundin KD. A versatile new mineralized bone strain for simultaneous assessment of tetracycline and osteoid seams. Stain Technol. 1989;64:129-138.
    • (1989) Stain Technol , vol.64 , pp. 129-138
    • Villanueva, A.R.1    Lundin, K.D.2
  • 13
    • 0027398456 scopus 로고
    • Influence of mineral content and composition on gray levels in backscattered electron images of bone
    • Skedros JG, Bloebaum RD, Bachus KN, Boyce TM, Constance B. Influence of mineral content and composition on gray levels in backscattered electron images of bone. J Biomed Mater Res. 1993;27:57-65.
    • (1993) J Biomed Mater Res , vol.27 , pp. 57-65
    • Skedros, J.G.1    Bloebaum, R.D.2    Bachus, K.N.3    Boyce, T.M.4    Constance, B.5
  • 14
    • 0017624346 scopus 로고
    • An independent "post-mortem" calibration of electrical resistance strain gauges bonded to bone surfaces "in vivo."
    • Baggot DG, Lanyon LE. An independent "post-mortem" calibration of electrical resistance strain gauges bonded to bone surfaces "in vivo." J Biomechanics. 1977;10:615-622.
    • (1977) J Biomechanics , vol.10 , pp. 615-622
    • Baggot, D.G.1    Lanyon, L.E.2
  • 16
    • 0028291062 scopus 로고
    • Bone remodeling and in vivo strain analysis of intact and implanted greyhound proximal femora
    • Szivek JA, Johnson EM, Magee FP, Emmanual J, Poser RD, Koeneman JB. Bone remodeling and in vivo strain analysis of intact and implanted greyhound proximal femora. J Invest Surg. 1994;7(3):213-233.
    • (1994) J Invest Surg , vol.7 , Issue.3 , pp. 213-233
    • Szivek, J.A.1    Johnson, E.M.2    Magee, F.P.3    Emmanual, J.4    Poser, R.D.5    Koeneman, J.B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.