Volumn 20, Issue 11, 1997, Pages 2799-2809

Clinical performance of steroid-eluting pacing leads with 1.2-mm2 electrodes

Author keywords

Electrode stability; Electrode surface; High impedance; High slew rates; Low threshold

Indexed keywords

STEROID;

EID: 0030696326     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1997.tb05438.x     Document Type: Article
Times cited : (20)

References (41)
  • 2
    • 0001938032 scopus 로고
    • Considerations in electrode design for permanent pacing
    • HJ Thalen (ed.): Assen, The Netherlands, Van Gorcum & Co.
    • Irnich W. Considerations in electrode design for permanent pacing. In HJ Thalen (ed.): Proceedings of the Fourth International Symposium on Cardiac Pacing. Assen, The Netherlands, Van Gorcum & Co., 1973, pp. 268-274.
    • (1973) Proceedings of the Fourth International Symposium on Cardiac Pacing , pp. 268-274
    • Irnich, W.1
  • 3
    • 0018748476 scopus 로고
    • The interdependence between electrogram, total electrode impedance and pacemaker input impedance necessary to obtain adequate functioning of demand pacemakers
    • Ohm O-J. The interdependence between electrogram, total electrode impedance and pacemaker input impedance necessary to obtain adequate functioning of demand pacemakers. PACE 1979; 2:465-485.
    • (1979) PACE , vol.2 , pp. 465-485
    • Ohm, O.-J.1
  • 5
    • 0026512433 scopus 로고
    • The electrode-tissue interface: The revolutionary role of steroid elution
    • Mond HG, Stokes KB. The electrode-tissue interface: The revolutionary role of steroid elution. PACE 1992; 15:95-107.
    • (1992) PACE , vol.15 , pp. 95-107
    • Mond, H.G.1    Stokes, K.B.2
  • 6
    • 0023024742 scopus 로고
    • Clinical experience with 910 carbon tip leads: Comparison with polished platinum leads
    • Mugica J, Henry L, Attuel P, et al. Clinical experience with 910 carbon tip leads: Comparison with polished platinum leads. PACE 1986; 9:1230-1238.
    • (1986) PACE , vol.9 , pp. 1230-1238
    • Mugica, J.1    Henry, L.2    Attuel, P.3
  • 7
    • 0344815884 scopus 로고
    • Comparison of fractally coated vs. conventional leads after three years of follow-up
    • A Otto (ed.): Bologna, Italy, Monduzzi Editore
    • Kamke W, Nitschke M, Krulls-Munch J, et al. Comparison of fractally coated vs. conventional leads after three years of follow-up. In A Otto (ed.): 7th European Symposium on Cardiac Pacing. Bologna, Italy, Monduzzi Editore, 1995, pp. 419-423.
    • (1995) 7th European Symposium on Cardiac Pacing , pp. 419-423
    • Kamke, W.1    Nitschke, M.2    Krulls-Munch, J.3
  • 8
    • 85047678035 scopus 로고
    • Acute voltage, charge, and energy thresholds as functions of electrode size for electrical stimulation of the canine heart
    • Lindemans FW, Zimmerman ANE. Acute voltage, charge, and energy thresholds as functions of electrode size for electrical stimulation of the canine heart. Cardiovasc Res 1979; 13:383-391.
    • (1979) Cardiovasc Res , vol.13 , pp. 383-391
    • Lindemans, F.W.1    Zimmerman, A.N.E.2
  • 10
    • 33744896197 scopus 로고
    • 2, porous, titanium-nitride electrode coated with membrane
    • 2, porous, titanium-nitride electrode coated with membrane. (abstract) Eur JCPE 1994; 4(Suppl. 4):86.
    • (1994) (Abstract) Eur JCPE , vol.4 , Issue.4 SUPPL. , pp. 86
    • Guerola, M.1    Lindegren, U.2
  • 11
    • 0025880948 scopus 로고
    • The mythology of threshold variations as a function of electrode surface area
    • Stokes KB, Bird T, Gunderson B. The mythology of threshold variations as a function of electrode surface area. PACE 1991; 14:1748-1751.
    • (1991) PACE , vol.14 , pp. 1748-1751
    • Stokes, K.B.1    Bird, T.2    Gunderson, B.3
  • 12
  • 14
    • 9044243404 scopus 로고    scopus 로고
    • 2 high impedance, steroid-eluting pacing electrodes
    • 2 high impedance, steroid-eluting pacing electrodes. PACE 1996; 19:188-196.
    • (1996) PACE , vol.19 , pp. 188-196
    • Fogel, R.1    Pirzada, F.2    Casavant, D.3
  • 15
    • 9844265497 scopus 로고
    • Electrical characteristics of third generation steroid-eluting pacing leads: Potential for a 17 year pace-maker battery life
    • Bersohn MM, Panzer SS, Prest-Berg K, et al. Electrical characteristics of third generation steroid-eluting pacing leads: Potential for a 17 year pace-maker battery life. (abstract) PACE 1994; 17:854.
    • (1994) (Abstract) PACE , vol.17 , pp. 854
    • Bersohn, M.M.1    Panzer, S.S.2    Prest-Berg, K.3
  • 17
    • 9844244100 scopus 로고    scopus 로고
    • Stimulation threshold behavior in tined endocardial leads
    • Danilovic D, Stroebel J, Ohm O-J, et al. Stimulation threshold behavior in tined endocardial leads. (abstract) Eur JCPE 1996; 6(Suppl. 5):217.
    • (1996) (Abstract) Eur JCPE , vol.6 , Issue.5 SUPPL. , pp. 217
    • Danilovic, D.1    Stroebel, J.2    Ohm, O.-J.3
  • 18
    • 0002283450 scopus 로고
    • Engineering concepts of pacemaker leads
    • GE Antonioli, AE Aubert, H Ector (eds.): Amsterdam, The Netherlands, Elsevier
    • Irnich W. Engineering concepts of pacemaker leads. In GE Antonioli, AE Aubert, H Ector (eds.): Pacemaker Leads 1991. Amsterdam, The Netherlands, Elsevier, 1991, pp. 3-19.
    • (1991) Pacemaker Leads 1991 , pp. 3-19
    • Irnich, W.1
  • 19
    • 0028894429 scopus 로고
    • Long-term follow-up of pacemaker lead systems: Establishment of standards of quality
    • Furman S, Benedek ZM, Andrews CA, et al. Long-term follow-up of pacemaker lead systems: Establishment of standards of quality. PACE 1995; 18:271-285.
    • (1995) PACE , vol.18 , pp. 271-285
    • Furman, S.1    Benedek, Z.M.2    Andrews, C.A.3
  • 20
    • 0025908901 scopus 로고
    • Long-term functional integrity of atrial leads
    • Parsonnet V, Hesselson AB, Harari DC. Long-term functional integrity of atrial leads. PACE 1991; 14:517-521.
    • (1991) PACE , vol.14 , pp. 517-521
    • Parsonnet, V.1    Hesselson, A.B.2    Harari, D.C.3
  • 21
    • 9844229452 scopus 로고
    • Clinical outcome of patients with atrial lead complications requiring operative reintervention: 15 years assessment
    • Hayes DL, VonFeldt LK. Clinical outcome of patients with atrial lead complications requiring operative reintervention: 15 years assessment. (abstract) PACE 1995; 18:1752.
    • (1995) (Abstract) PACE , vol.18 , pp. 1752
    • Hayes, D.L.1    VonFeldt, L.K.2
  • 22
    • 0025045994 scopus 로고
    • Stimulation characteristics of a steroid-eluting electrode compared with three conventional electrodes
    • Klein HH, Steinberger J, Knake W. Stimulation characteristics of a steroid-eluting electrode compared with three conventional electrodes. PACE 1990; 13:134-137.
    • (1990) PACE , vol.13 , pp. 134-137
    • Klein, H.H.1    Steinberger, J.2    Knake, W.3
  • 23
    • 0029586692 scopus 로고
    • A randomised controlled clinical study to quantify the effect of small changes in the design of pacing electrodes on threshold voltages
    • Murray A, Jameson S, Gold RG. A randomised controlled clinical study to quantify the effect of small changes in the design of pacing electrodes on threshold voltages. PACE 1995; 18:2150-2154.
    • (1995) PACE , vol.18 , pp. 2150-2154
    • Murray, A.1    Jameson, S.2    Gold, R.G.3
  • 24
    • 9844244649 scopus 로고
    • A comparison between unipolar and bipolar leads with small-surface low-energy electrodes
    • Guerola M, Lindegren U. A comparison between unipolar and bipolar leads with small-surface low-energy electrodes. (abstract) Eur JCPE 1994: 4(Suppl. 4):94.
    • (1994) (Abstract) Eur JCPE , vol.4 , Issue.4 SUPPL. , pp. 94
    • Guerola, M.1    Lindegren, U.2
  • 25
    • 9844224582 scopus 로고
    • Benefits of a new steroid-eluting lead with high impedance
    • Gammage MD, Willems R, and the European Multicenter Study Group. Benefits of a new steroid-eluting lead with high impedance. (abstract) PACE 1995; 18:867.
    • (1995) (Abstract) PACE , vol.18 , pp. 867
    • Gammage, M.D.1    Willems, R.2
  • 26
    • 0344004970 scopus 로고
    • High impedance and low energy stimulation with bipolar ultra small electrode surface area steroid-eluting lead (Medtronic CapSure Z). Preliminary result
    • Puglisi A, Ricci R, Adornato E, et al. High impedance and low energy stimulation with bipolar ultra small electrode surface area steroid-eluting lead (Medtronic CapSure Z). Preliminary result. (abstract) PACE 1995; 18:1791.
    • (1995) (Abstract) PACE , vol.18 , pp. 1791
    • Puglisi, A.1    Ricci, R.2    Adornato, E.3
  • 27
    • 2242493187 scopus 로고
    • Acute and long-term sensing and pacing performance of pacemaker leads having titanium nitride electrode tips
    • GE Antonioli, AE Aubert, H Ector (eds.): Amsterdam, The Netherlands, Elsevier
    • Schaldach M, Bolz A, Breme J, et al. Acute and long-term sensing and pacing performance of pacemaker leads having titanium nitride electrode tips. In GE Antonioli, AE Aubert, H Ector (eds.): Pacemaker Leads 1991. Amsterdam, The Netherlands, Elsevier, 1991, pp. 441-450.
    • (1991) Pacemaker Leads 1991 , pp. 441-450
    • Schaldach, M.1    Bolz, A.2    Breme, J.3
  • 29
    • 0026672634 scopus 로고
    • Assessment of long term stability of chronic ventricular pacing thresholds in steroid-eluting electrodes
    • Stojanov P, Djordjevic M, Velimirovic D, et al. Assessment of long term stability of chronic ventricular pacing thresholds in steroid-eluting electrodes. PACE 1992; 15:1417-1420.
    • (1992) PACE , vol.15 , pp. 1417-1420
    • Stojanov, P.1    Djordjevic, M.2    Velimirovic, D.3
  • 30
    • 0027315354 scopus 로고
    • Do steroid-eluting electrodes really have better performance than other state-of-the-art designs?
    • Santini M, DeSeta F, and the Italian Multicenter Study Group on Low Output Stimulation. Do steroid-eluting electrodes really have better performance than other state-of-the-art designs? PACE 1993; 16:722-728.
    • (1993) PACE , vol.16 , pp. 722-728
    • Santini, M.1    DeSeta, F.2
  • 31
    • 0021202250 scopus 로고
    • Optimal pace-maker sensing with respect to amplitude and slew rate of intracardiac electrograms: Theoretical analysis by computer simulation
    • Arai Y, Yamazoe M, Toeda T, et al. Optimal pace-maker sensing with respect to amplitude and slew rate of intracardiac electrograms: Theoretical analysis by computer simulation. PACE 1984; 7:778-783.
    • (1984) PACE , vol.7 , pp. 778-783
    • Arai, Y.1    Yamazoe, M.2    Toeda, T.3
  • 32
    • 0025888991 scopus 로고
    • Pacing threshold spikes months and years after implant
    • Shepard RB, Kim J, Colvin EC, et al. Pacing threshold spikes months and years after implant. PACE 1991; 14:1835-1841.
    • (1991) PACE , vol.14 , pp. 1835-1841
    • Shepard, R.B.1    Kim, J.2    Colvin, E.C.3
  • 33
    • 0024383436 scopus 로고
    • Pacing failure due to markedly increased stimulation threshold 2 years after implantation: Successful management with oral prednisolone: A case report
    • Nagatomo Y, Ogawa T, Kumagae H, et al. Pacing failure due to markedly increased stimulation threshold 2 years after implantation: Successful management with oral prednisolone: A case report. PACE 1989; 12:1034-1037.
    • (1989) PACE , vol.12 , pp. 1034-1037
    • Nagatomo, Y.1    Ogawa, T.2    Kumagae, H.3
  • 34
    • 9844225148 scopus 로고    scopus 로고
    • Forceful heart contractions lead to unexpected threshold behavior
    • Danilovic D, Ohm O-J, Hoff PI, et al. Forceful heart contractions lead to unexpected threshold behavior. (abstract) Eur JCPE 1996; 6(Suppl. 5):169.
    • (1996) (Abstract) Eur JCPE , vol.6 , Issue.5 SUPPL. , pp. 169
    • Danilovic, D.1    Ohm, O.-J.2    Hoff, P.I.3
  • 35
    • 0002448940 scopus 로고
    • Differences in atrial and ventricular pacing lead impedances - Data on 2,682 leads
    • Schallhorn R, Markowitz T. Differences in atrial and ventricular pacing lead impedances - data on 2,682 leads. (abstract) PACE 1990; 13:551.
    • (1990) (Abstract) PACE , vol.13 , pp. 551
    • Schallhorn, R.1    Markowitz, T.2
  • 36
    • 0025040366 scopus 로고
    • Atrial and ventricular stimulation threshold development: A comparative study in patients with a DDD pace-maker and two identical carbon-tip leads
    • Brandt J, Attewell R, Fahraeus T, et al. Atrial and ventricular stimulation threshold development: A comparative study in patients with a DDD pace-maker and two identical carbon-tip leads. PACE 1990; 13:859-866.
    • (1990) PACE , vol.13 , pp. 859-866
    • Brandt, J.1    Attewell, R.2    Fahraeus, T.3
  • 37
    • 9844257114 scopus 로고
    • All impedances are not created equal: Efficiency vs. expediency
    • Stokes K, Taepke B, Gates J. All impedances are not created equal: Efficiency vs. expediency. Medtronic science and technology 1994; 3(1):2-12.
    • (1994) Medtronic Science and Technology , vol.3 , Issue.1 , pp. 2-12
    • Stokes, K.1    Taepke, B.2    Gates, J.3
  • 38
    • 0023238884 scopus 로고
    • Pacing and sensing: How can one electrode fulfill both requirements?
    • Sinneave A, Willems R, Backers J, et al. Pacing and sensing: How can one electrode fulfill both requirements? PACE 1987; 10:546-554.
    • (1987) PACE , vol.10 , pp. 546-554
    • Sinneave, A.1    Willems, R.2    Backers, J.3
  • 39
    • 0020961288 scopus 로고
    • Electrode-heart interface: Definition of the ideal electrode
    • Ripart A, Mugica J. Electrode-heart interface: Definition of the ideal electrode. PACE 1983; 6:410-421.
    • (1983) PACE , vol.6 , pp. 410-421
    • Ripart, A.1    Mugica, J.2
  • 40
    • 33744842786 scopus 로고
    • Mini-tip leads give a possibility for low pacemaker outputs and high pacemaker longevity
    • Danilovic D, Breivik K, Ohm O-J, et al. Mini-tip leads give a possibility for low pacemaker outputs and high pacemaker longevity. (abstract) PACE 1995; 18:1187.
    • (1995) (Abstract) PACE , vol.18 , pp. 1187
    • Danilovic, D.1    Breivik, K.2    Ohm, O.-J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.