메뉴 건너뛰기




Volumn 70, Issue SPECIAL.ISSUE, 1997, Pages

MRI developments in perspective

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN FUNCTION; CONTRAST; ENGINEERING; HISTORY OF MEDICINE; MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; REVIEW; TISSUE PERFUSION; TOMOGRAPHY; UNITED KINGDOM;

EID: 0030696307     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr.1997.0010     Document Type: Review
Times cited : (10)

References (91)
  • 1
    • 33746803555 scopus 로고
    • Image formation by induced local interactions: Examples employing nuclear magnetic resonance
    • Lauterbur PC. Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature 1973;242:190-1.
    • (1973) Nature , vol.242 , pp. 190-191
    • Lauterbur, P.C.1
  • 2
    • 0022642035 scopus 로고
    • Cancer detection by nuclear magnetic resonance zeugmatographic imaging
    • Lauterbur PC. Cancer detection by nuclear magnetic resonance zeugmatographic imaging. Cancer 1986;57:1899-1904.
    • (1986) Cancer , vol.57 , pp. 1899-1904
    • Lauterbur, P.C.1
  • 3
    • 0015232094 scopus 로고
    • Tumor detection by nuclear magnetic resonance
    • Damadian R. Tumor detection by nuclear magnetic resonance. Science 1971;171:1151-3.
    • (1971) Science , vol.171 , pp. 1151-1153
    • Damadian, R.1
  • 6
    • 0018855804 scopus 로고
    • Nuclear magnetic resonance (NMR) tomography of the brain: A preliminary clinical assessment with demonstration of pathology
    • Hawkes RC, Holland GN, Moore WS, Worthington BS. Nuclear magnetic resonance (NMR) tomography of the brain: a preliminary clinical assessment with demonstration of pathology. JCAT 1980;4:577-86.
    • (1980) JCAT , vol.4 , pp. 577-586
    • Hawkes, R.C.1    Holland, G.N.2    Moore, W.S.3    Worthington, B.S.4
  • 7
    • 0019837567 scopus 로고
    • Magnetic resonance properties of hydrogen: Imaging the posterior fossa
    • Young IR, Burl M, Clarke GJ, Hall AS, Pasmore T, Collins AG, et al. Magnetic resonance properties of hydrogen: imaging the posterior fossa. AJR 1981;137:895-901.
    • (1981) AJR , vol.137 , pp. 895-901
    • Young, I.R.1    Burl, M.2    Clarke, G.J.3    Hall, A.S.4    Pasmore, T.5    Collins, A.G.6
  • 11
    • 0016984868 scopus 로고
    • Image formation by nuclear magnetic resonance: The sensitive-point method
    • Hinshaw WS. Image formation by nuclear magnetic resonance: the sensitive-point method. J Appl Phys 1976;47:3709-21.
    • (1976) J Appl Phys , vol.47 , pp. 3709-3721
    • Hinshaw, W.S.1
  • 12
    • 0019164710 scopus 로고
    • Nuclear magnetic resonance imaging
    • Moore WS, Holland GN. Nuclear magnetic resonance imaging. Br Med Bull 1980;36:297-9.
    • (1980) Br Med Bull , vol.36 , pp. 297-299
    • Moore, W.S.1    Holland, G.N.2
  • 14
    • 0016315551 scopus 로고
    • Image formation in NMR by a selective irradiation process
    • Garroway AN, Grannell PK, Mansfield P. Image formation in NMR by a selective irradiation process. J Phys [C] 1974;7:L457-62.
    • (1974) J Phys [C] , vol.7
    • Garroway, A.N.1    Grannell, P.K.2    Mansfield, P.3
  • 15
    • 0041923329 scopus 로고
    • Zeugmatography - A criticism of the concept of a selective pulse in the presence of a field gradient
    • Hoult DI. Zeugmatography - a criticism of the concept of a selective pulse in the presence of a field gradient. J Magn Reson 1977;26:165-7.
    • (1977) J Magn Reson , vol.26 , pp. 165-167
    • Hoult, D.I.1
  • 16
    • 0017940980 scopus 로고
    • NMR imaging: Image recovery under magnetic fields with large non-uniformities
    • Hutchison JMS, Sutherland RJ, Mallard JR. NMR imaging: image recovery under magnetic fields with large non-uniformities. J Phys [E] 1978;11:217-21.
    • (1978) J Phys [E] , vol.11 , pp. 217-221
    • Hutchison, J.M.S.1    Sutherland, R.J.2    Mallard, J.R.3
  • 19
    • 0029969908 scopus 로고    scopus 로고
    • Application of the principle of optical phase-contrast microscopy to velocity phase-encoded MRI of blood flow in the aorta
    • Dymond RC, Redpath TW, McKiddie FI. Application of the principle of optical phase-contrast microscopy to velocity phase-encoded MRI of blood flow in the aorta. Br J Radiol 1996;69:410-4.
    • (1996) Br J Radiol , vol.69 , pp. 410-414
    • Dymond, R.C.1    Redpath, T.W.2    McKiddie, F.I.3
  • 20
    • 0021235637 scopus 로고
    • Direct cardiac NMR imaging of heart wall and blood flow velocity
    • van Dijk P. Direct cardiac NMR imaging of heart wall and blood flow velocity. JCAT 1984;8:429-36.
    • (1984) JCAT , vol.8 , pp. 429-436
    • Van Dijk, P.1
  • 21
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • Bryant DJ, Payne JA, Firmin DN, Longmore DB. Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. JCAT 1984;8:588-93.
    • (1984) JCAT , vol.8 , pp. 588-593
    • Bryant, D.J.1    Payne, J.A.2    Firmin, D.N.3    Longmore, D.B.4
  • 22
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon WT. Simple proton spectroscopic imaging. Radiology 1984;153:189-94.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 23
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin-echoes
    • Mansfield P. Multi-planar image formation using NMR spin-echoes. J Phys [C] 1977;10:L55-L58.
    • (1977) J Phys [C] , vol.10
    • Mansfield, P.1
  • 24
    • 49349125543 scopus 로고
    • Biological and medical imaging by NMR
    • Mansfield P. Biological and medical imaging by NMR. J Magn Reson 1978;29:355-73.
    • (1978) J Magn Reson , vol.29 , pp. 355-373
    • Mansfield, P.1
  • 26
    • 0000132799 scopus 로고
    • The sensitivity of the zeugmatographic experiment involving human samples
    • Hoult DI, Lauterbur PC. The sensitivity of the zeugmatographic experiment involving human samples. J Magn Reson 1979;34:425-33.
    • (1979) J Magn Reson , vol.34 , pp. 425-433
    • Hoult, D.I.1    Lauterbur, P.C.2
  • 28
    • 1842270296 scopus 로고
    • Clinical results with the Diasonics NMR instrument
    • London DA, Crooks LE, Margulis AR. Clinical results with the Diasonics NMR instrument. JCAT 1982;6:1220.
    • (1982) JCAT , vol.6 , pp. 1220
    • London, D.A.1    Crooks, L.E.2    Margulis, A.R.3
  • 29
    • 1842316411 scopus 로고
    • Massachusetts General Hospital clinical experience in patients with CNS pathology using two NMR imaging techniques. Comparison with X-ray CT
    • Brady TJ, Buonanno FS, Pykett IL, New PFJ, Goldman MR, Hinshaw WS, et al. Massachusetts General Hospital clinical experience in patients with CNS pathology using two NMR imaging techniques. Comparison with X-ray CT. JCAT 1982;6:1220.
    • (1982) JCAT , vol.6 , pp. 1220
    • Brady, T.J.1    Buonanno, F.S.2    Pykett, I.L.3    New, P.F.J.4    Goldman, M.R.5    Hinshaw, W.S.6
  • 34
    • 0024428747 scopus 로고
    • MR imaging of the knee: Three-dimensional volume imaging combined with fast processing
    • Adam G, Bohndorf K, Drobnitzky M, Guenther RW. MR imaging of the knee: three-dimensional volume imaging combined with fast processing. JCAT 1989;13:984-8.
    • (1989) JCAT , vol.13 , pp. 984-988
    • Adam, G.1    Bohndorf, K.2    Drobnitzky, M.3    Guenther, R.W.4
  • 35
    • 0025333678 scopus 로고
    • Comparing the cost of spinal MR with conventional myelography and radiculography
    • Du Boulay GH, Hawkes S, Lee C-C, Teather BA, Teather D. Comparing the cost of spinal MR with conventional myelography and radiculography. Neuroradiol 1990;32:124-36.
    • (1990) Neuroradiol , vol.32 , pp. 124-136
    • Du Boulay, G.H.1    Hawkes, S.2    Lee, C.-C.3    Teather, B.A.4    Teather, D.5
  • 36
    • 0022799736 scopus 로고
    • The field dependence of NMR imaging II. Arguments concerning an optimal field strength
    • Hoult DI, Chen C-N, Sank VJ. The field dependence of NMR imaging II. Arguments concerning an optimal field strength, Magn Reson Med 1986;3:730-46.
    • (1986) Magn Reson Med , vol.3 , pp. 730-746
    • Hoult, D.I.1    Chen, C.-N.2    Sank, V.J.3
  • 37
    • 0021674799 scopus 로고
    • Quadrature detection in the laboratory frame
    • Hoult DI, Chen C-N, Sank VJ. Quadrature detection in the laboratory frame. Magn Reson Med 1984;1:339-53.
    • (1984) Magn Reson Med , vol.1 , pp. 339-353
    • Hoult, D.I.1    Chen, C.-N.2    Sank, V.J.3
  • 38
    • 46549092488 scopus 로고
    • An efficient, highly homogeneous radio-frequency coil for whole-body NMR imaging at 1.5T
    • Hayes CE, Edelstein WA, Schenck JF, Mueller OM, Eash M. An efficient, highly homogeneous radio-frequency coil for whole-body NMR imaging at 1.5T. J Magn Reson 1985;63:622-8.
    • (1985) J Magn Reson , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenck, J.F.3    Mueller, O.M.4    Eash, M.5
  • 41
    • 0021280733 scopus 로고
    • Surface coil magnetic resonance imaging
    • Axel L. Surface coil magnetic resonance imaging. JCAT 1984;8:381-4.
    • (1984) JCAT , vol.8 , pp. 381-384
    • Axel, L.1
  • 43
    • 0025832121 scopus 로고
    • Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: Optimisation of corrections and quantitative characterisation of magnet/ gradient systems
    • Boesch C, Gruetter R, Martin E. Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimisation of corrections and quantitative characterisation of magnet/ gradient systems. Magn Reson Med 1991;20:268-84.
    • (1991) Magn Reson Med , vol.20 , pp. 268-284
    • Boesch, C.1    Gruetter, R.2    Martin, E.3
  • 45
    • 1842278104 scopus 로고    scopus 로고
    • Axial magnetic field gradient coil suitable for use with NMR apparatus. US patent no. 4,617,516, filed September 1983
    • Schenk JF. Axial magnetic field gradient coil suitable for use with NMR apparatus. US patent no. 4,617,516, filed September 1983.
    • Schenk, J.F.1
  • 46
    • 1842309801 scopus 로고    scopus 로고
    • Transverse gradient field coils for nuclear magnetic resonance imaging. US patent no. 4,646,024, filed November 1983
    • Schenck JF, Hussain MA, Edelstein WA. Transverse gradient field coils for nuclear magnetic resonance imaging. US patent no. 4,646,024, filed November 1983.
    • Schenck, J.F.1    Hussain, M.A.2    Edelstein, W.A.3
  • 47
    • 0022768413 scopus 로고
    • A target field approach to optimal coil design
    • Turner R. A target field approach to optimal coil design. J Phys [D] 1986;19:L147-L151.
    • (1986) J Phys [D] , vol.19
    • Turner, R.1
  • 48
    • 0000389382 scopus 로고
    • Active magnetic screening of gradient coils in NMR imaging
    • Mansfield P, Chapman B. Active magnetic screening of gradient coils in NMR imaging. J Magn Reson 1986;66:573-6.
    • (1986) J Magn Reson , vol.66 , pp. 573-576
    • Mansfield, P.1    Chapman, B.2
  • 49
    • 0022796641 scopus 로고
    • Passive screening of switched magnetic-field gradients
    • Turner R, Bowley RM. Passive screening of switched magnetic-field gradients. J Phys [E] 1986;19:876-9.
    • (1986) J Phys [E] , vol.19 , pp. 876-879
    • Turner, R.1    Bowley, R.M.2
  • 51
    • 1842324104 scopus 로고    scopus 로고
    • Magnetic resonance imaging systems: method of suppressing eddy currents induced in components of MRI. US patent no. 4,733,189, filed June 1986
    • Pillsbury RD, Punchard WF. Magnetic resonance imaging systems: method of suppressing eddy currents induced in components of MRI. US patent no. 4,733,189, filed June 1986.
    • Pillsbury, R.D.1    Punchard, W.F.2
  • 52
    • 0011246260 scopus 로고
    • Acceptance testing of magnetic resonance imagers: Which tests are worthwhile
    • Dixon RL, editor. Madison, WI: Medical Physics Publishing Corp
    • Purdy DE. Acceptance testing of magnetic resonance imagers: which tests are worthwhile. In: Dixon RL, editor. MRI: Acceptance Testing and Quality Control. The Role of the Clinical Medical Physicist. Madison, WI: Medical Physics Publishing Corp, 1988:115-25.
    • (1988) MRI: Acceptance Testing and Quality Control. The Role of the Clinical Medical Physicist , pp. 115-125
    • Purdy, D.E.1
  • 53
    • 1842394662 scopus 로고    scopus 로고
    • Moving gradient zeugmatography, US patent no. 4,307,343, filed August 1979
    • Likes RS. Moving gradient zeugmatography, US patent no. 4,307,343, filed August 1979.
    • Likes, R.S.1
  • 54
    • 0020644027 scopus 로고
    • The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods
    • Tweig DB. The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. Med Phys 1983;10:610-21.
    • (1983) Med Phys , vol.10 , pp. 610-621
    • Tweig, D.B.1
  • 55
    • 0022900074 scopus 로고
    • Blood flow imaging by cine magnetic resonance
    • Nayler GL, Firmin DN, Longmore DB. Blood flow imaging by cine magnetic resonance. JCAT 1986;10:715-22.
    • (1986) JCAT , vol.10 , pp. 715-722
    • Nayler, G.L.1    Firmin, D.N.2    Longmore, D.B.3
  • 57
    • 0023197057 scopus 로고
    • Spatial presaturation: A method for suppressing flow artefacts and improving depiction of vascular anatomy in MR imaging
    • Felmlee JP, Ehman RL. Spatial presaturation: a method for suppressing flow artefacts and improving depiction of vascular anatomy in MR imaging. Radiology 1987;164:559-64.
    • (1987) Radiology , vol.164 , pp. 559-564
    • Felmlee, J.P.1    Ehman, R.L.2
  • 58
    • 0023832968 scopus 로고
    • FRODO pulse sequences: A new means of eliminating motion, flow, and wraparound artifacts
    • Edelman RR, Atkinson DJ, Silver MS, Loaiza FL, Warren WS. FRODO pulse sequences: a new means of eliminating motion, flow, and wraparound artifacts. Radiology 1988;166:231-6.
    • (1988) Radiology , vol.166 , pp. 231-236
    • Edelman, R.R.1    Atkinson, D.J.2    Silver, M.S.3    Loaiza, F.L.4    Warren, W.S.5
  • 59
    • 1842346194 scopus 로고    scopus 로고
    • Methods of producing image information from objects. UK patent no. GB 2079463B, priority date March 1980
    • Edelstein WA, Hutchinson JMS, Johnson G, Redpath TW, Mallard JR. Methods of producing image information from objects. UK patent no. GB 2079463B, priority date March 1980.
    • Edelstein, W.A.1    Hutchinson, J.M.S.2    Johnson, G.3    Redpath, T.W.4    Mallard, J.R.5
  • 60
    • 0022508305 scopus 로고
    • Rapid non-tomographic approach to MR myelography without contrast agents
    • Hennig J, Friedburg H, Stroebel B. Rapid non-tomographic approach to MR myelography without contrast agents. JCAT 1986;10:375-8.
    • (1986) JCAT , vol.10 , pp. 375-378
    • Hennig, J.1    Friedburg, H.2    Stroebel, B.3
  • 61
    • 0022686199 scopus 로고
    • High-speed spiral-scan echo planar NMR imaging-I
    • Ahn CB, Kim JH, Cho ZH. High-speed spiral-scan echo planar NMR imaging-I. IEEE Trans Med Imag 1986;MI-5:2-7.
    • (1986) IEEE Trans Med Imag , vol.MI-5 , pp. 2-7
    • Ahn, C.B.1    Kim, J.H.2    Cho, Zh.3
  • 63
    • 0002521965 scopus 로고
    • Application of Fourier transform spectroscopy to magnetic resonance
    • Ernst RR, Anderson WA. Application of Fourier transform spectroscopy to magnetic resonance. Rev Sci Instrum 1966;37:93-102.
    • (1966) Rev Sci Instrum , vol.37 , pp. 93-102
    • Ernst, R.R.1    Anderson, W.A.2
  • 64
    • 0020620433 scopus 로고
    • Signal, noise, and contrast in nuclear magnetic resonance (NMR) imaging
    • Edelstein WA, Bottomley PA, Hart HR, Smith LS. Signal, noise, and contrast in nuclear magnetic resonance (NMR) imaging. JCAT 1983;7:391-401.
    • (1983) JCAT , vol.7 , pp. 391-401
    • Edelstein, W.A.1    Bottomley, P.A.2    Hart, H.R.3    Smith, L.S.4
  • 65
    • 0023705696 scopus 로고
    • The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences
    • Gyngell M. The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences. Magn Reson Imaging 1988;6:415-9.
    • (1988) Magn Reson Imaging , vol.6 , pp. 415-419
    • Gyngell, M.1
  • 66
    • 0025213880 scopus 로고
    • 2, and chemical-shift imaging
    • 2, and chemical-shift imaging. Magn Reson Med 1990;13:77-89.
    • (1990) Magn Reson Med , vol.13 , pp. 77-89
    • Haase, A.1
  • 68
    • 0026501082 scopus 로고
    • Brain hemorrhage: Evaluation with fast spin-echo and conventional dual spin-echo images
    • Jones KM, Mulkern RV, Mantello MT, Melki PS, Ahn SS, Barnes PD, et al. Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images. Radiology 1992;182:53-8.
    • (1992) Radiology , vol.182 , pp. 53-58
    • Jones, K.M.1    Mulkern, R.V.2    Mantello, M.T.3    Melki, P.S.4    Ahn, S.S.5    Barnes, P.D.6
  • 70
    • 0029884174 scopus 로고    scopus 로고
    • The influence of stimulated echoes on contrast in fast spin-echo imaging
    • Williams CFM, Redpath TW, Smith FW. The influence of stimulated echoes on contrast in fast spin-echo imaging. Magn Reson Imaging 1996;14:419-28.
    • (1996) Magn Reson Imaging , vol.14 , pp. 419-428
    • Williams, C.F.M.1    Redpath, T.W.2    Smith, F.W.3
  • 72
    • 0024318207 scopus 로고
    • Intracranial circulation: Preliminary clinical results with three-dimensional (volume) MR angiography
    • Masaryk TJ, Modic MT, Ross JS, Ruggieri PM, Laub GA, Lenz GW, et al. Intracranial circulation: preliminary clinical results with three-dimensional (volume) MR angiography. Radiology 1989;171: 793-9.
    • (1989) Radiology , vol.171 , pp. 793-799
    • Masaryk, T.J.1    Modic, M.T.2    Ross, J.S.3    Ruggieri, P.M.4    Laub, G.A.5    Lenz, G.W.6
  • 73
    • 0023913360 scopus 로고
    • MR angiography with gradient motion refocusing
    • Laub GA, Kaiser WA. MR angiography with gradient motion refocusing. JCAT 1988;12:377-82.
    • (1988) JCAT , vol.12 , pp. 377-382
    • Laub, G.A.1    Kaiser, W.A.2
  • 74
    • 0023007579 scopus 로고
    • Magnetic resonance angiography
    • Dumoulin CL, Hart HR. Magnetic resonance angiography. Radiology 1986;161:717-20.
    • (1986) Radiology , vol.161 , pp. 717-720
    • Dumoulin, C.L.1    Hart, H.R.2
  • 75
    • 0021356595 scopus 로고
    • Intravenous chelated gadolinium as a contrast agent in NMR imaging of cerebral tumours
    • Carr DH, Brown J, Bydder GM, Weinmann H-J, Speck U, Thomas DJ, et al. Intravenous chelated gadolinium as a contrast agent in NMR imaging of cerebral tumours. Lancet 1984;i:484-6.
    • (1984) Lancet , vol.1 , pp. 484-486
    • Carr, D.H.1    Brown, J.2    Bydder, G.M.3    Weinmann, H.-J.4    Speck, U.5    Thomas, D.J.6
  • 76
    • 0023801420 scopus 로고
    • Superparamagnetic iron oxide: Clinical application as a contrast agent for MR imaging of the liver
    • Stark DD, Weissleder R, Elizondo G, Hahn PF, Saini S, Todd LE, et al. Superparamagnetic iron oxide: clinical application as a contrast agent for MR imaging of the liver. Radiology 1988;168:297-301.
    • (1988) Radiology , vol.168 , pp. 297-301
    • Stark, D.D.1    Weissleder, R.2    Elizondo, G.3    Hahn, P.F.4    Saini, S.5    Todd, L.E.6
  • 78
    • 0026011540 scopus 로고
    • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts
    • Tofts PS, Kermode AG. Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts. Magn Reson Med 1991;17:357-67.
    • (1991) Magn Reson Med , vol.17 , pp. 357-367
    • Tofts, P.S.1    Kermode, A.G.2
  • 80
    • 0028885070 scopus 로고
    • Quantification of rheumatoid synovitis by magnetic resonance imaging
    • Gaffney K, Cookson J, Blake D, Coumbe A, Blades S. Quantification of rheumatoid synovitis by magnetic resonance imaging. Arthritis Rheum 1995;38:1610-7.
    • (1995) Arthritis Rheum , vol.38 , pp. 1610-1617
    • Gaffney, K.1    Cookson, J.2    Blake, D.3    Coumbe, A.4    Blades, S.5
  • 81
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci USA 1990;87:9868-72.
    • (1990) Proc Natl Acad Sci USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 84
    • 0028005698 scopus 로고
    • Brain or vein - Oxygenation or flow? on signal physiology in functional MRI of human brain activation
    • Frahm J, Merboldt K-D, Haenicke W, Kleinschmidt A, Boecker H. Brain or vein - oxygenation or flow? On signal physiology in functional MRI of human brain activation. NMR Biomed 1994;7:45-53.
    • (1994) NMR Biomed , vol.7 , pp. 45-53
    • Frahm, J.1    Merboldt, K.-D.2    Haenicke, W.3    Kleinschmidt, A.4    Boecker, H.5
  • 86
    • 0026761501 scopus 로고
    • Fast magnetic resonance diffusion-weighted imaging of acute human stroke
    • Warach S, Chien D, Li W, Ronthal M, Edelman RR. Fast magnetic resonance diffusion-weighted imaging of acute human stroke. Neurology 1992;42:1717-23.
    • (1992) Neurology , vol.42 , pp. 1717-1723
    • Warach, S.1    Chien, D.2    Li, W.3    Ronthal, M.4    Edelman, R.R.5
  • 90
    • 0030012099 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging of perfusion using magnetic labelling of water proton spins within the detection slice
    • Schwarzbauer C, Morrissey SP, Haase A. Quantitative magnetic resonance imaging of perfusion using magnetic labelling of water proton spins within the detection slice. Magn Reson Med 1996;35:540-6.
    • (1996) Magn Reson Med , vol.35 , pp. 540-546
    • Schwarzbauer, C.1    Morrissey, S.P.2    Haase, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.