-
1
-
-
0025124459
-
Transvenous atrial septal occlusion in piglets using a "buttoned" double-disc device
-
Sideris EB, Sideris SE, Fowlkes JP, Ehly RJ, Smith JE, Gulde RE. Transvenous atrial septal occlusion in piglets using a "buttoned" double-disc device. Circulation. 81:1990;312-318.
-
(1990)
Circulation
, vol.81
, pp. 312-318
-
-
Sideris, E.B.1
Sideris, S.E.2
Fowlkes, J.P.3
Ehly, R.J.4
Smith, J.E.5
Gulde, R.E.6
-
2
-
-
0025605559
-
Transvenous atrial septal defect occlusion by the "buttoned" device
-
Sideris EB, Sideris SE, Thanopoulous BD, Ehly RL, Fowlkes JP. Transvenous atrial septal defect occlusion by the "buttoned" device. Am J Cardiol. 66:1990;1524-1526.
-
(1990)
Am J Cardiol
, vol.66
, pp. 1524-1526
-
-
Sideris, E.B.1
Sideris, S.E.2
Thanopoulous, B.D.3
Ehly, R.L.4
Fowlkes, J.P.5
-
3
-
-
0026530603
-
Role of "buttoned" double disc device in the management of atrial septal defects
-
Rao PS, Wilson AD, Levy JM, Gupta VK, Chopra PS. Role of "buttoned" double disc device in the management of atrial septal defects. Am Heart J. 123:1992;191-200.
-
(1992)
Am Heart J
, vol.123
, pp. 191-200
-
-
Rao, P.S.1
Wilson, A.D.2
Levy, J.M.3
Gupta, V.K.4
Chopra, P.S.5
-
4
-
-
0027057437
-
Transcatheter closure of atrial septal defects by "buttoned" devices
-
Rao PS, Wilson AD, Chopra PS. Transcatheter closure of atrial septal defects by "buttoned" devices. Am J Cardiol. 69:1992;1056-1061.
-
(1992)
Am J Cardiol
, vol.69
, pp. 1056-1061
-
-
Rao, P.S.1
Wilson, A.D.2
Chopra, P.S.3
-
5
-
-
0028008388
-
Atrial septal defect occlusion with buttoned device: A multi-institutional U.S. trial
-
Lloyd TR, Rao PS, Beekman RH III, Mendelsohn AM, Sideris EB. Atrial septal defect occlusion with buttoned device: a multi-institutional U.S. trial. Am J Cardiol. 73:1994;286-291.
-
(1994)
Am J Cardiol
, vol.73
, pp. 286-291
-
-
Lloyd, T.R.1
Rao, P.S.2
Beekman R.H. III3
Mendelsohn, A.M.4
Sideris, E.B.5
-
6
-
-
0028139119
-
International experience with secundum atrial septal defect occlusion by the buttoned device
-
Rao PS, Sideris EB, Hausdorf G, Rey C, Lloyd TR, Beekman RH, Worms AM, Bourlan F, Onorato E, Khalilullah M, Haddad J. International experience with secundum atrial septal defect occlusion by the buttoned device. Am Heart J. 128:1994;1022-1035.
-
(1994)
Am Heart J
, vol.128
, pp. 1022-1035
-
-
Rao, P.S.1
Sideris, E.B.2
Hausdorf, G.3
Rey, C.4
Lloyd, T.R.5
Beekman, R.H.6
Worms, A.M.7
Bourlan, F.8
Onorato, E.9
Khalilullah, M.10
Haddad, J.11
-
7
-
-
0029154378
-
Follow-up results of transcatheter occlusion of atrial septal defects with buttoned device
-
Rao PS, Ende DJ, Wilson AD, Smith PA, Chopra PS. Follow-up results of transcatheter occlusion of atrial septal defects with buttoned device. Can J Cardiol. 11:1995;695-701.
-
(1995)
Can J Cardiol
, vol.11
, pp. 695-701
-
-
Rao, P.S.1
Ende, D.J.2
Wilson, A.D.3
Smith, P.A.4
Chopra, P.S.5
-
8
-
-
0030035976
-
Transcatheter closure of atrial septal defect or patent foramen ovale with the buttoned device for prevention of paradoxic embolism
-
Ende DE, Chopra PS, Rao PS. Transcatheter closure of atrial septal defect or patent foramen ovale with the buttoned device for prevention of paradoxic embolism. Am J Cardiol. 78:1996;233-236.
-
(1996)
Am J Cardiol
, vol.78
, pp. 233-236
-
-
Ende, D.E.1
Chopra, P.S.2
Rao, P.S.3
-
9
-
-
0017863110
-
Measurement of atrial septal defect during cardiac catheterization: Experimental and clinical results
-
King TD, Thompson SL, Mills NL. Measurement of atrial septal defect during cardiac catheterization: experimental and clinical results. Am J Cardiol. 41:1978;537-542.
-
(1978)
Am J Cardiol
, vol.41
, pp. 537-542
-
-
King, T.D.1
Thompson, S.L.2
Mills, N.L.3
-
10
-
-
0025797609
-
Relationship of echocardiographic, shunt flow, and angiographic size to stretched diameter of the atrial septal defect
-
Rao PS, Langhough R. Relationship of echocardiographic, shunt flow, and angiographic size to stretched diameter of the atrial septal defect. Am Heart J. 122:1991;505-508.
-
(1991)
Am Heart J
, vol.122
, pp. 505-508
-
-
Rao, P.S.1
Langhough, R.2
-
11
-
-
0026750429
-
Echocardiographic estimation of balloon stretched diameter of secundum atrial septal defects for transcatheter occlusion
-
Rao PS, Langhough R, Beekman RH, Lloyd TR, Sideris EB. Echocardiographic estimation of balloon stretched diameter of secundum atrial septal defects for transcatheter occlusion. Am Heart J. 124:1992;172-175.
-
(1992)
Am Heart J
, vol.124
, pp. 172-175
-
-
Rao, P.S.1
Langhough, R.2
Beekman, R.H.3
Lloyd, T.R.4
Sideris, E.B.5
-
12
-
-
0017300623
-
Secundum atrial septa defect: Nonoperative closure during cardiac catheterization
-
King TD, Thompson SL, Steiner C, Mills NL. Secundum atrial septa defect: nonoperative closure during cardiac catheterization. JAMA. 235:1976;2506-2509.
-
(1976)
JAMA
, vol.235
, pp. 2506-2509
-
-
King, T.D.1
Thompson, S.L.2
Steiner, C.3
Mills, N.L.4
-
13
-
-
0020700882
-
Transcatheter treatment of congenital heart disease
-
Rashkind WJ. Transcatheter treatment of congenital heart disease. Circulation. 67:1983;711-716.
-
(1983)
Circulation
, vol.67
, pp. 711-716
-
-
Rashkind, W.J.1
-
14
-
-
0024554238
-
Transcatheter closure of atrial septal defects: Experimental studies
-
Lock JE, Rome JJ, Davis R, Van Praagh S, Perry SB, Van Praagh R, Keane JF. Transcatheter closure of atrial septal defects: experimental studies. Circulation. 79:1989;1091-1099.
-
(1989)
Circulation
, vol.79
, pp. 1091-1099
-
-
Lock, J.E.1
Rome, J.J.2
Davis, R.3
Van Praagh, S.4
Perry, S.B.5
Van Praagh, R.6
Keane, J.F.7
-
15
-
-
0024991050
-
Double-umbrella closure of atrial defects: Initial clinical applications
-
Rome JJ, Keane JF, Perry SB, Spevak PJ, Lock JE. Double-umbrella closure of atrial defects: initial clinical applications. Circulation. 82:1990;751-758.
-
(1990)
Circulation
, vol.82
, pp. 751-758
-
-
Rome, J.J.1
Keane, J.F.2
Perry, S.B.3
Spevak, P.J.4
Lock, J.E.5
-
16
-
-
0027291830
-
Monodisk: Device for percutaneous transcatheter closure of cardiac septal defects
-
Pavenik D, Wright KG, Wallace S. Monodisk: device for percutaneous transcatheter closure of cardiac septal defects. Cardiovasc Intervent Radiol. 16:1993;308-312.
-
(1993)
Cardiovasc Intervent Radiol
, vol.16
, pp. 308-312
-
-
Pavenik, D.1
Wright, K.G.2
Wallace, S.3
-
17
-
-
0027515761
-
Experimental atrial septal defect closure with a new, transcatheter, self-centering device
-
Das GS, Voss G, Jarvis G, Wyche BS, Gunther R, Wilson RF. Experimental atrial septal defect closure with a new, transcatheter, self-centering device. Circulation. 88:1993;1754-1767.
-
(1993)
Circulation
, vol.88
, pp. 1754-1767
-
-
Das, G.S.1
Voss, G.2
Jarvis, G.3
Wyche, B.S.4
Gunther, R.5
Wilson, R.F.6
-
18
-
-
0028809385
-
Transcatheter closure of large atrial septal defects with Babic system
-
Silvert H, Babic M, Ensslen R, et al. Transcatheter closure of large atrial septal defects with Babic system. Cathet Cardiovasc Diagn. 36:1995;232-240.
-
(1995)
Cathet Cardiovasc Diagn
, vol.36
, pp. 232-240
-
-
Silvert, H.1
Babic, M.2
Ensslen, R.3
-
19
-
-
0026564953
-
Transcatheter closure of patent foramen ovale after presumed paradoxical embolism
-
Bridges ND, Hellenbrand W, Latson L, Filiano J, Newburger JW, Lock JE. Transcatheter closure of patent foramen ovale after presumed paradoxical embolism. Circulation. 86:1992;1902-1908.
-
(1992)
Circulation
, vol.86
, pp. 1902-1908
-
-
Bridges, N.D.1
Hellenbrand, W.2
Latson, L.3
Filiano, J.4
Newburger, J.W.5
Lock, J.E.6
-
20
-
-
0025037294
-
Baffle fenestration with subsequent transcatheter closure: Modification of the Fontan operation for patients at increased risk
-
Bridges ND, Lock JE, Castaneda AR. Baffle fenestration with subsequent transcatheter closure: modification of the Fontan operation for patients at increased risk. Circulation. 82:1990;1681-1689.
-
(1990)
Circulation
, vol.82
, pp. 1681-1689
-
-
Bridges, N.D.1
Lock, J.E.2
Castaneda, A.R.3
-
21
-
-
0026762849
-
Fenestrated Fontan with delayed catheter ASD closure: Improved results in high risk patients
-
Kopf GS, Kleinman CS, Hijazi ZM, Fahey JT, Dewar ML, Hellenbrand WE. Fenestrated Fontan with delayed catheter ASD closure: improved results in high risk patients. J Thorac Cardiovasc Surg. 103:1992;1039-1047.
-
(1992)
J Thorac Cardiovasc Surg
, vol.103
, pp. 1039-1047
-
-
Kopf, G.S.1
Kleinman, C.S.2
Hijazi, Z.M.3
Fahey, J.T.4
Dewar, M.L.5
Hellenbrand, W.E.6
-
22
-
-
0027942187
-
Transcatheter closure of interatrial communication with a modified umbrella device
-
Redington AN, Rigby ML. Transcatheter closure of interatrial communication with a modified umbrella device. Br Heart J. 72:1994;372-377.
-
(1994)
Br Heart J
, vol.72
, pp. 372-377
-
-
Redington, A.N.1
Rigby, M.L.2
-
23
-
-
0026654564
-
Hemodynamic evaluation before and after closure of fenestrated Fontan: An acute study of changes in oxygen delivery
-
Hijazi ZM, Fahey JT, Kleinman CS, Kopf GS, Hellenbrand WE. Hemodynamic evaluation before and after closure of fenestrated Fontan: an acute study of changes in oxygen delivery. Circulation. 88:1992;196-202.
-
(1992)
Circulation
, vol.88
, pp. 196-202
-
-
Hijazi, Z.M.1
Fahey, J.T.2
Kleinman, C.S.3
Kopf, G.S.4
Hellenbrand, W.E.5
-
24
-
-
0028227437
-
Acute hemodynamic effects of adjustable atrial septal defect closure in the lateral tunnel Fontan procedure
-
Harake B, Kuhn MA, Jarmakani JM, Laks H, Al-Khatib Y, Elami A, Williams RG. Acute hemodynamic effects of adjustable atrial septal defect closure in the lateral tunnel Fontan procedure. J Am Coll Cardiol. 23:1994;1671-1677.
-
(1994)
J Am Coll Cardiol
, vol.23
, pp. 1671-1677
-
-
Harake, B.1
Kuhn, M.A.2
Jarmakani, J.M.3
Laks, H.4
Al-Khatib, Y.5
Elami, A.6
Williams, R.G.7
-
25
-
-
0029022193
-
Effect of late postoperative atrial septal defect closure on hemodynamic function in patients with lateral tunnel Fontan procedure
-
Kuhn MA, Jarmakani JM, Laks H, Alejos JC, Permut LC, Galindo A, Isabel-Jones JB. Effect of late postoperative atrial septal defect closure on hemodynamic function in patients with lateral tunnel Fontan procedure. J Am Coll Cardiol. 26:1995;259-265.
-
(1995)
J Am Coll Cardiol
, vol.26
, pp. 259-265
-
-
Kuhn, M.A.1
Jarmakani, J.M.2
Laks, H.3
Alejos, J.C.4
Permut, L.C.5
Galindo, A.6
Isabel-Jones, J.B.7
-
26
-
-
0029020068
-
Cardiac Catheterization and test occlusion of the interatrial communication after fenestrated Fontan operation
-
Bridges ND, Lock JE, Mayer JE, Burnett J, Castaneda AR. Cardiac Catheterization and test occlusion of the interatrial communication after fenestrated Fontan operation. J Am Coll Cardiol. 25:1995;1712-1717.
-
(1995)
J Am Coll Cardiol
, vol.25
, pp. 1712-1717
-
-
Bridges, N.D.1
Lock, J.E.2
Mayer, J.E.3
Burnett, J.4
Castaneda, A.R.5
-
27
-
-
0028824043
-
Use of the reversed button device to treat an atrial septal aneurysm associated with a patent foramen ovale
-
Mehan VK, Sideris EB, Meier B. Use of the reversed button device to treat an atrial septal aneurysm associated with a patent foramen ovale. Br Heart J. 74:1995;563-565.
-
(1995)
Br Heart J
, vol.74
, pp. 563-565
-
-
Mehan, V.K.1
Sideris, E.B.2
Meier, B.3
-
28
-
-
0029048907
-
Systemic thromboembolism leading to myocardial infarction and stroke after fenestrated total cavopulmonary connection
-
Wilson DG, Wisheart JD, Stuart AG. Systemic thromboembolism leading to myocardial infarction and stroke after fenestrated total cavopulmonary connection. Br Heart J. 73:1995;483-485.
-
(1995)
Br Heart J
, vol.73
, pp. 483-485
-
-
Wilson, D.G.1
Wisheart, J.D.2
Stuart, A.G.3
|