메뉴 건너뛰기




Volumn 12, Issue 4, 1997, Pages 232-249

Transthoracic needle biopsy: An overview

Author keywords

Computed tomography; Cytopathology; Lung biopsy; Lung neoplasms

Indexed keywords

AIR EMBOLISM; BIOPSY; BLEEDING; COMPUTER ASSISTED TOMOGRAPHY; HUMAN; LUNG BIOPSY; LUNG NODULE; NEEDLE BIOPSY; PNEUMOTHORAX; REVIEW;

EID: 0030690203     PISSN: 08835993     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005382-199710000-00002     Document Type: Review
Times cited : (84)

References (145)
  • 1
    • 0025238446 scopus 로고
    • Radiologic evaluation of the solitary pulmonary nodule
    • Webb WR. Radiologic evaluation of the solitary pulmonary nodule. AJR Am J Roentgenol 1990 154:701-8.
    • (1990) AJR Am J Roentgenol , vol.154 , pp. 701-708
    • Webb, W.R.1
  • 2
    • 0025979490 scopus 로고
    • Transthoracic percutaneous fine-needle aspiration biopsy in the chest and mediastinum
    • Weisbrod GL. Transthoracic percutaneous fine-needle aspiration biopsy in the chest and mediastinum. Seminars in Interventional Radiology 1991;8:1-14.
    • (1991) Seminars in Interventional Radiology , vol.8 , pp. 1-14
    • Weisbrod, G.L.1
  • 3
    • 0025861042 scopus 로고
    • The value of negative needle biopsy in suspected operable lung cancer
    • Charig MJ, Stutley JE, Padley SPG, et al. The value of negative needle biopsy in suspected operable lung cancer. Clin Radiol 1991;44:147-9.
    • (1991) Clin Radiol , vol.44 , pp. 147-149
    • Charig, M.J.1    Stutley, J.E.2    Padley, S.P.G.3
  • 4
    • 0015309093 scopus 로고
    • Dissemination of cancer cells by needle biopsy of the lung
    • Berger R, Dargan E, Huang B. Dissemination of cancer cells by needle biopsy of the lung. J Thorac Cardiovasc Surg 1972;63: 430-2.
    • (1972) J Thorac Cardiovasc Surg , vol.63 , pp. 430-432
    • Berger, R.1    Dargan, E.2    Huang, B.3
  • 5
    • 0029979394 scopus 로고    scopus 로고
    • Bronchoscopic diagnosis of solitary pulmonary nodules and lung masses in the absence of endobronchial abnormality
    • Chechani V. Bronchoscopic diagnosis of solitary pulmonary nodules and lung masses in the absence of endobronchial abnormality. Chest 1996;109:620-5.
    • (1996) Chest , vol.109 , pp. 620-625
    • Chechani, V.1
  • 7
    • 0027190339 scopus 로고
    • Needle aspiration biopsy of malignant lung masses with necrotic centers. Improved sensitivity with ultrasound guidance
    • Pan JF, Yang PC, Chang DB, Lee YC, Kuo SH, Luh KT. Needle aspiration biopsy of malignant lung masses with necrotic centers. Improved sensitivity with ultrasound guidance. Chest 1993;103: 1452-6.
    • (1993) Chest , vol.103 , pp. 1452-1456
    • Pan, J.F.1    Yang, P.C.2    Chang, D.B.3    Lee, Y.C.4    Kuo, S.H.5    Luh, K.T.6
  • 8
    • 0021709263 scopus 로고
    • CT assistance for fluoroscopically guided transthoracic needle aspiration biopsy
    • Cohan RH, Newman GE, Braun SD, et al: CT assistance for fluoroscopically guided transthoracic needle aspiration biopsy. J Comput Assist Tomogr 1984;8:1093-8.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 1093-1098
    • Cohan, R.H.1    Newman, G.E.2    Braun, S.D.3
  • 10
    • 0025854807 scopus 로고
    • Ultrasound-guided aspiration biopsy of anterior mediastinal masses
    • Tikkakoski T, Lohela P, Leppanen M, et al. Ultrasound-guided aspiration biopsy of anterior mediastinal masses. J Clin Ultrasound 1991;19:209-14.
    • (1991) J Clin Ultrasound , vol.19 , pp. 209-214
    • Tikkakoski, T.1    Lohela, P.2    Leppanen, M.3
  • 12
    • 0025764656 scopus 로고
    • Tru-Cut biopsy of mediastinal masses guided by real-time ultrasound
    • Sawhney S, Jain R, Berry M. Tru-Cut biopsy of mediastinal masses guided by real-time ultrasound. Clin Radiol 1991;44: 16-9.
    • (1991) Clin Radiol , vol.44 , pp. 16-19
    • Sawhney, S.1    Jain, R.2    Berry, M.3
  • 13
    • 0029064627 scopus 로고
    • CT-guided automated needle biopsy of the chest
    • Haramati LB. CT-guided automated needle biopsy of the chest. AJR Am J Roentgenol 1995;165:53-5.
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 53-55
    • Haramati, L.B.1
  • 14
    • 0000688821 scopus 로고    scopus 로고
    • Transthoracic needle biopsy practices: Results of a nationwide survey
    • Protopapas Z, White CS, Miller BH, Miller DL, Westcott JL. Transthoracic needle biopsy practices: Results of a nationwide survey [Abstract]. Radiology 1996;201(suppl):270.
    • (1996) Radiology , vol.201 , Issue.SUPPL. , pp. 270
    • Protopapas, Z.1    White, C.S.2    Miller, B.H.3    Miller, D.L.4    Westcott, J.L.5
  • 15
    • 0028787379 scopus 로고
    • Informed consent for percutaneous lung biopsy. Comparison of two consent protocols based on patient recall after the procedure
    • White CS, Mason AC, Feehan M, Templeton PA. Informed consent for percutaneous lung biopsy. Comparison of two consent protocols based on patient recall after the procedure. AJR Am J Roentgenol 1995;165:1139-42.
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 1139-1142
    • White, C.S.1    Mason, A.C.2    Feehan, M.3    Templeton, P.A.4
  • 16
    • 0027495723 scopus 로고
    • Percutaneous transthoracic needle biopsy in AIDS: Analysis in 32 patients
    • Gruden JF, Klein JS, Webb WR. Percutaneous transthoracic needle biopsy in AIDS: analysis in 32 patients. Radiology 1993; 189:567-71.
    • (1993) Radiology , vol.189 , pp. 567-571
    • Gruden, J.F.1    Klein, J.S.2    Webb, W.R.3
  • 18
    • 0021997060 scopus 로고
    • Transthoracic needle aspiration biopsy of benign and malignant lung lesions
    • Khouri NF, Stitik FP, Erozan YS, et al. Transthoracic needle aspiration biopsy of benign and malignant lung lesions. AJR Am J Roentgenol 1985;144:281-8.
    • (1985) AJR Am J Roentgenol , vol.144 , pp. 281-288
    • Khouri, N.F.1    Stitik, F.P.2    Erozan, Y.S.3
  • 20
    • 0023154051 scopus 로고
    • Lung lesions: Cytologic diagnosis by fine-needle biopsy
    • Stanley JH, Fish GD, Andriole JG, et al. Lung lesions: cytologic diagnosis by fine-needle biopsy. Radiology 1987;162:389-91.
    • (1987) Radiology , vol.162 , pp. 389-391
    • Stanley, J.H.1    Fish, G.D.2    Andriole, J.G.3
  • 21
    • 0018954348 scopus 로고
    • Direct percutaneous needle aspiration of localized pulmonary lesions: Results in 422 patients
    • Westcott JL. Direct percutaneous needle aspiration of localized pulmonary lesions: results in 422 patients. Radiology 1980;137: 31-5.
    • (1980) Radiology , vol.137 , pp. 31-35
    • Westcott, J.L.1
  • 23
    • 0020696976 scopus 로고
    • CT-guided fine needle aspirations for diagnosis of benign and malignant disease
    • Harter LP, Moss AA, Goldberg HI, et al. CT-guided fine needle aspirations for diagnosis of benign and malignant disease. AJR Am J Roentgenol 1983;140:363-7.
    • (1983) AJR Am J Roentgenol , vol.140 , pp. 363-367
    • Harter, L.P.1    Moss, A.A.2    Goldberg, H.I.3
  • 25
    • 0023265432 scopus 로고
    • Hilar masses: Evaluation with CT-guided biopsy after negative bronchoscopic examination
    • Sider L, Davis TM Jr. Hilar masses: evaluation with CT-guided biopsy after negative bronchoscopic examination. Radiology 1987;164:107-9.
    • (1987) Radiology , vol.164 , pp. 107-109
    • Sider, L.1    Davis T.M., Jr.2
  • 26
    • 0026532510 scopus 로고
    • Coaxial transthoracic fine-needle biopsy in patients with a history of malignant lymphoma
    • Wittich GR, Nowels KW, Korn RL, et al. Coaxial transthoracic fine-needle biopsy in patients with a history of malignant lymphoma. Radiology 1992;183:175-8.
    • (1992) Radiology , vol.183 , pp. 175-178
    • Wittich, G.R.1    Nowels, K.W.2    Korn, R.L.3
  • 27
    • 0023178196 scopus 로고
    • Neoplastic superior vena caval obstruction: Diagnosis with percutaneous needle aspiration
    • Cosmo L, Haponik EF, Darlak JJ, et al. Neoplastic superior vena caval obstruction: diagnosis with percutaneous needle aspiration. Am J Med Sci 1987;293:99-102.
    • (1987) Am J Med Sci , vol.293 , pp. 99-102
    • Cosmo, L.1    Haponik, E.F.2    Darlak, J.J.3
  • 28
    • 0028324956 scopus 로고
    • Mediastinal masses: Alternative approaches to CT-guided needle biopsy
    • Bressler EL, Kirkham JA. Mediastinal masses: alternative approaches to CT-guided needle biopsy. Radiology 1994;191: 391-6.
    • (1994) Radiology , vol.191 , pp. 391-396
    • Bressler, E.L.1    Kirkham, J.A.2
  • 29
    • 0023321481 scopus 로고
    • Computed tomographic-guided stereotactic biopsy of thoracic lesions
    • Costello P, Onik G, Cosman E. Computed tomographic-guided stereotactic biopsy of thoracic lesions. J Thorac Imag 1987;2:27-32.
    • (1987) J Thorac Imag , vol.2 , pp. 27-32
    • Costello, P.1    Onik, G.2    Cosman, E.3
  • 30
    • 0024998588 scopus 로고
    • A guidance device for CT-guided procedures
    • Reyes GD. A guidance device for CT-guided procedures. Radiology 1990;176:863-1
    • (1990) Radiology , vol.176 , pp. 863-871
    • Reyes, G.D.1
  • 34
    • 0021814990 scopus 로고
    • Use of the Rotex needle in percutaneous biopsy of pulmonary malignancy
    • Nahman BJ, Van Aman ME, McLemore WE, et al. Use of the Rotex needle in percutaneous biopsy of pulmonary malignancy. AJR Am J Roentgenol 1985;145:97-9.
    • (1985) AJR Am J Roentgenol , vol.145 , pp. 97-99
    • Nahman, B.J.1    Van Aman, M.E.2    McLemore, W.E.3
  • 35
    • 0023959907 scopus 로고
    • A comparative study of the Chiba and Turner needles in percutaneous lung biopsy
    • Yap J, Tan KP. A comparative study of the Chiba and Turner needles in percutaneous lung biopsy. Sing Med J 1988;29:14-6.
    • (1988) Sing Med J , vol.29 , pp. 14-16
    • Yap, J.1    Tan, K.P.2
  • 37
    • 0021799406 scopus 로고
    • Supplementary tissue-core histology from fine-needle transthoracic aspiration biopsy
    • Greene R, Szyfelbein WM, Isler RJ, et al. Supplementary tissue-core histology from fine-needle transthoracic aspiration biopsy. AJR Am J Roentgenol 1985;144:787-92.
    • (1985) AJR Am J Roentgenol , vol.144 , pp. 787-792
    • Greene, R.1    Szyfelbein, W.M.2    Isler, R.J.3
  • 40
    • 0026584979 scopus 로고
    • Temno biopsy needle: Evaluation of efficacy and safety in 165 biopsy procedures
    • Quinn SF, Demlow T, Dunkley B. Temno biopsy needle: evaluation of efficacy and safety in 165 biopsy procedures. AJR Am J Roentgenol 1992;158:641-3.
    • (1992) AJR Am J Roentgenol , vol.158 , pp. 641-643
    • Quinn, S.F.1    Demlow, T.2    Dunkley, B.3
  • 41
    • 0024432960 scopus 로고
    • Low-risk large-needle biopsy of chest lesions
    • Clore F, Virapongse C, Saterfiel J. Low-risk large-needle biopsy of chest lesions. Chest 1989;96:538-41.
    • (1989) Chest , vol.96 , pp. 538-541
    • Clore, F.1    Virapongse, C.2    Saterfiel, J.3
  • 42
    • 0029038280 scopus 로고
    • Percutaneous needle biopsy of localized pulmonary, mediastinal, and pleural diseased tissue with an automated guillotine soft-tissue needle
    • Noppen MMP, De Mey J, Meysman M, Opdebeeck B, Vincken WG, Osteaux M. Percutaneous needle biopsy of localized pulmonary, mediastinal, and pleural diseased tissue with an automated guillotine soft-tissue needle. Chest 1995;107:1615-20.
    • (1995) Chest , vol.107 , pp. 1615-1620
    • Noppen, M.M.P.1    De Mey, J.2    Meysman, M.3    Opdebeeck, B.4    Vincken, W.G.5    Osteaux, M.6
  • 43
    • 0343673691 scopus 로고    scopus 로고
    • CT-guided biopsy of small lung lesions: Usefulness of spring-operated core biopsy needle and frozen section pathologic diagnosis
    • Hayashi N, Sakai T, Kitagawa M, Inagaki R, Ishii Y. CT-guided biopsy of small lung lesions: usefulness of spring-operated core biopsy needle and frozen section pathologic diagnosis [Abstract]. Radiology 1996;201(suppl):269-70.
    • (1996) Radiology , vol.201 , Issue.SUPPL. , pp. 269-270
    • Hayashi, N.1    Sakai, T.2    Kitagawa, M.3    Inagaki, R.4    Ishii, Y.5
  • 44
  • 45
    • 0342368541 scopus 로고    scopus 로고
    • CT-guided coaxial percutaneous core biopsy of lung lesions with an 18-gauge automated cutting needle system
    • Lucidarme O, Finet J, Beigelman C, Mourey-Gerosa I, Grenier PA. CT-guided coaxial percutaneous core biopsy of lung lesions with an 18-gauge automated cutting needle system [Abstract]. Radiology 1996;201(suppl):270.
    • (1996) Radiology , vol.201 , Issue.SUPPL. , pp. 270
    • Lucidarme, O.1    Finet, J.2    Beigelman, C.3    Mourey-Gerosa, I.4    Grenier, P.A.5
  • 46
    • 0027157586 scopus 로고
    • CT gantry tilt: Utility in transthoracic fine-neelde aspiration biopsy. Work in progress
    • Stern EJ, Webb WR, Gamsu G. CT gantry tilt: utility in transthoracic fine-neelde aspiration biopsy. Work in progress. Radiology 1993;187:873-4.
    • (1993) Radiology , vol.187 , pp. 873-874
    • Stern, E.J.1    Webb, W.R.2    Gamsu, G.3
  • 47
    • 0028324217 scopus 로고
    • To tilt or not to tilt?
    • Yankelevitz DF. To tilt or not to tilt? [Letter] Radiology 1994; 191:585.
    • (1994) Radiology , vol.191 , pp. 585
    • Yankelevitz, D.F.1
  • 48
    • 0029910173 scopus 로고    scopus 로고
    • "Oblique path" - The optimal needle path for computed tomography-guided biopsy of small subpleural lesions
    • Tanaka J, Sonomura T, Shioyama Y, et al. "Oblique path" - The optimal needle path for computed tomography-guided biopsy of small subpleural lesions. Cardiovasc Intervent Radiol 1996;19: 332-4.
    • (1996) Cardiovasc Intervent Radiol , vol.19 , pp. 332-334
    • Tanaka, J.1    Sonomura, T.2    Shioyama, Y.3
  • 49
    • 0025088249 scopus 로고
    • Transosseous approach for transthoracic needle biopsy
    • Glynn TP Jr. Transosseous approach for transthoracic needle biopsy. Radiology 1990;177:278-9.
    • (1990) Radiology , vol.177 , pp. 278-279
    • Glynn T.P., Jr.1
  • 50
    • 0027359411 scopus 로고
    • Anterior mediastinal lesions: Transsternal biopsy with CT guidance. Work in progress
    • D'Agostino HB, Sanchez RB, Laoide RM, et al. Anterior mediastinal lesions: transsternal biopsy with CT guidance. Work in progress. Radiology 1993;189:703-5.
    • (1993) Radiology , vol.189 , pp. 703-705
    • D'Agostino, H.B.1    Sanchez, R.B.2    Laoide, R.M.3
  • 51
    • 0029878132 scopus 로고    scopus 로고
    • CT-guided transsternal core biopsy of anterior mediastinal masses
    • Astrom KGO, Ahlstrom KH, Magnusson A. CT-guided transsternal core biopsy of anterior mediastinal masses. Radiology 1996; 199:564-7.
    • (1996) Radiology , vol.199 , pp. 564-567
    • Astrom, K.G.O.1    Ahlstrom, K.H.2    Magnusson, A.3
  • 52
    • 0027200789 scopus 로고
    • Percutaneous CT biopsy of chest lesions: An in-vitro analysis of the effect of partial volume averaging on needle positioning
    • Yankelevitz DF, Henschke CI, Davis SD. Percutaneous CT biopsy of chest lesions: an in-vitro analysis of the effect of partial volume averaging on needle positioning. AJR Am J Roentgenol 1993;161:273-8.
    • (1993) AJR Am J Roentgenol , vol.161 , pp. 273-278
    • Yankelevitz, D.F.1    Henschke, C.I.2    Davis, S.D.3
  • 53
    • 0023943990 scopus 로고
    • Difficult thoracic lesions: CT-guided biopsy experience in 150 cases
    • van Sonnenberg E, Casola G, Ho M, et al. Difficult thoracic lesions: CT-guided biopsy experience in 150 cases. Radiology 1988;167:457-61.
    • (1988) Radiology , vol.167 , pp. 457-461
    • Van Sonnenberg, E.1    Casola, G.2    Ho, M.3
  • 54
    • 0020630025 scopus 로고
    • Percutaneous biopsy of difficult mediastinal, hilar, and pulmonary lesions by computed tomographic guidance and a modified coaxial technique
    • van Sonnenberg E, Lin AS, Deutsch AL, et al. Percutaneous biopsy of difficult mediastinal, hilar, and pulmonary lesions by computed tomographic guidance and a modified coaxial technique. Radiology 1983;148:300-2.
    • (1983) Radiology , vol.148 , pp. 300-302
    • Van Sonnenberg, E.1    Lin, A.S.2    Deutsch, A.L.3
  • 56
    • 0029914061 scopus 로고    scopus 로고
    • Capillary versus aspiration biopsy: Effect of needle size and length on the cytopathological specimen quality
    • Hopper KD, Grenko RT, Fisher AI, TenHave TR. Capillary versus aspiration biopsy: effect of needle size and length on the cytopathological specimen quality. Cardiovasc Intervent Radiol 1996;19:341-4.
    • (1996) Cardiovasc Intervent Radiol , vol.19 , pp. 341-344
    • Hopper, K.D.1    Grenko, R.T.2    Fisher, A.I.3    Tenhave, T.R.4
  • 57
    • 0029784871 scopus 로고    scopus 로고
    • Evaluation of the ThinPrep processor for fine-needle aspiration specimens
    • Lee KR, Papillo JL, St. John T, Eyerer GJA. Evaluation of the ThinPrep processor for fine-needle aspiration specimens. Acta Cytol 1996;40:895-9.
    • (1996) Acta Cytol , vol.40 , pp. 895-899
    • Lee, K.R.1    Papillo, J.L.2    St John, T.3    Eyerer, G.J.A.4
  • 58
    • 0027142988 scopus 로고
    • The sticky biopsy specimen: A saline solution
    • Wachsberg RH. The sticky biopsy specimen: a saline solution. AJR Am J Roentgenol 1993;161:1336-7.
    • (1993) AJR Am J Roentgenol , vol.161 , pp. 1336-1337
    • Wachsberg, R.H.1
  • 59
    • 0028234270 scopus 로고
    • CT detection of small pneumothorax
    • Yankelevitz DF. CT detection of small pneumothorax [Letter]. AJR Am J Roentgenol 1994;163:220.
    • (1994) AJR Am J Roentgenol , vol.163 , pp. 220
    • Yankelevitz, D.F.1
  • 60
    • 0025331754 scopus 로고
    • Positional precautions in needle aspiration lung biopsy
    • Moore EH, Shepard JO, McLoud TC, et al. Positional precautions in needle aspiration lung biopsy. Radiology 1990;175:733-5.
    • (1990) Radiology , vol.175 , pp. 733-735
    • Moore, E.H.1    Shepard, J.O.2    McLoud, T.C.3
  • 61
    • 0025991465 scopus 로고
    • Effects of patient positioning after needle aspiration lung biopsy
    • Moore EH, LeBlanc J, Montesi SA, et al. Effects of patient positioning after needle aspiration lung biopsy. Radiology 1991; 181:385-7.
    • (1991) Radiology , vol.181 , pp. 385-387
    • Moore, E.H.1    LeBlanc, J.2    Montesi, S.A.3
  • 63
    • 0022574889 scopus 로고
    • Timing of chest film followup after transthoracic needle aspiration
    • Perlmutt LM, Braun SD, Newman GE, et al. Timing of chest film followup after transthoracic needle aspiration. AJR Am J Roentgenol 1986;146:1049-50.
    • (1986) AJR Am J Roentgenol , vol.146 , pp. 1049-1050
    • Perlmutt, L.M.1    Braun, S.D.2    Newman, G.E.3
  • 64
    • 0025014515 scopus 로고
    • Powered cutting needle biopsy of the pleura and chest wall
    • Gleeson F, Lomas DJ, Flower CDR, et al. Powered cutting needle biopsy of the pleura and chest wall. Clin Radiol 1990;41:199-200.
    • (1990) Clin Radiol , vol.41 , pp. 199-200
    • Gleeson, F.1    Lomas, D.J.2    Flower, C.D.R.3
  • 66
    • 0024536006 scopus 로고
    • Six years' experience with perthoracic core needle biopsy of pulmonary lesions
    • Morgenroth A, Pfeuffer HP, Austgen M, et al. Six years' experience with perthoracic core needle biopsy of pulmonary lesions. Thorax 1989;44:177-83.
    • (1989) Thorax , vol.44 , pp. 177-183
    • Morgenroth, A.1    Pfeuffer, H.P.2    Austgen, M.3
  • 67
    • 0025144821 scopus 로고
    • Diagnostic value of percutaneous lung needle aspiration in patients with pneumonia
    • Torres A, Jimenez P, de la Bellacasa JP, et al. Diagnostic value of percutaneous lung needle aspiration in patients with pneumonia. Chest 1990;98:840-4.
    • (1990) Chest , vol.98 , pp. 840-844
    • Torres, A.1    Jimenez, P.2    De La Bellacasa, J.P.3
  • 68
    • 0019844349 scopus 로고
    • Percutaneous needle aspiration of hilar and mediastinal masses
    • Westcott JL. Percutaneous needle aspiration of hilar and mediastinal masses. Radiology 1981;141:323-9.
    • (1981) Radiology , vol.141 , pp. 323-329
    • Westcott, J.L.1
  • 69
    • 0023350919 scopus 로고
    • Thoracic needle biopsy: Improved results utilizing the team approach
    • Conces DJ, Schwenk R, Doering PR. Thoracic needle biopsy: improved results utilizing the team approach. Chest 1987;91: 813-22.
    • (1987) Chest , vol.91 , pp. 813-822
    • Conces, D.J.1    Schwenk, R.2    Doering, P.R.3
  • 70
    • 0023011878 scopus 로고
    • Fine-needle aspiration biopsy of the mediastinum
    • Linder J, Olsen GA, Johnston WW. Fine-needle aspiration biopsy of the mediastinum. Am J Med 1986;81:1005-8.
    • (1986) Am J Med , vol.81 , pp. 1005-1008
    • Linder, J.1    Olsen, G.A.2    Johnston, W.W.3
  • 71
    • 0025978560 scopus 로고
    • Role of percutaneous fine-needle aspiration biopsy in suspected intrathoracic malignancy
    • Colquhoun SD, Rosenthal DL, Morton DL. Role of percutaneous fine-needle aspiration biopsy in suspected intrathoracic malignancy. Ann Thorac Surg 1991;51:390-393.
    • (1991) Ann Thorac Surg , vol.51 , pp. 390-393
    • Colquhoun, S.D.1    Rosenthal, D.L.2    Morton, D.L.3
  • 72
    • 0023547116 scopus 로고
    • Postbiopsy pneumothorax: Estimating the risk by chest radiography and pulmonary function tests
    • Fish GD, Stanley JH, Miller KS, et al. Postbiopsy pneumothorax: estimating the risk by chest radiography and pulmonary function tests. AJR Am J Roentgenol 1988;150:71-4.
    • (1988) AJR Am J Roentgenol , vol.150 , pp. 71-74
    • Fish, G.D.1    Stanley, J.H.2    Miller, K.S.3
  • 73
    • 0023908309 scopus 로고
    • Prediction of pneumothorax rate in percutaneous needle aspiration in the lung
    • Miller KS, Fish GB, Stanley JH, et al. Prediction of pneumothorax rate in percutaneous needle aspiration in the lung. Chest 1988; 93:742-5.
    • (1988) Chest , vol.93 , pp. 742-745
    • Miller, K.S.1    Fish, G.B.2    Stanley, J.H.3
  • 75
    • 0029979393 scopus 로고    scopus 로고
    • Transthoracic needle aspiration in patients with severe emphysema. A study of lung transplant candidates
    • Kazerooni EA, Hartker FW, Whyte RI, Martinez FJ, Lynch JP. Transthoracic needle aspiration in patients with severe emphysema. A study of lung transplant candidates. Chest 1996; 109:616-620.
    • (1996) Chest , vol.109 , pp. 616-620
    • Kazerooni, E.A.1    Hartker, F.W.2    Whyte, R.I.3    Martinez, F.J.4    Lynch, J.P.5
  • 76
    • 0021327535 scopus 로고
    • Predicting risk of pneumothorax in needle biopsy of the lung
    • Poe RH, Kallay MC, Wicks CM, et al. Predicting risk of pneumothorax in needle biopsy of the lung. Chest 1984;85:232-5.
    • (1984) Chest , vol.85 , pp. 232-235
    • Poe, R.H.1    Kallay, M.C.2    Wicks, C.M.3
  • 77
    • 0030063957 scopus 로고    scopus 로고
    • Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    • Kazerooni EA, Lim FT, Mikhail A, Martinez FJ. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 1996;198:371-5.
    • (1996) Radiology , vol.198 , pp. 371-375
    • Kazerooni, E.A.1    Lim, F.T.2    Mikhail, A.3    Martinez, F.J.4
  • 78
    • 0029868708 scopus 로고    scopus 로고
    • The role of functional respiratory tests in predicting pneumothorax during lung needle biopsy
    • Vitulo P, Dore R, Cerveri I, Tinelli C, Cremaschi P. The role of functional respiratory tests in predicting pneumothorax during lung needle biopsy. Chest 1996;109:612-5.
    • (1996) Chest , vol.109 , pp. 612-615
    • Vitulo, P.1    Dore, R.2    Cerveri, I.3    Tinelli, C.4    Cremaschi, P.5
  • 79
    • 0028227102 scopus 로고
    • Risk of pneumothorax not increased by obstructive lung disease in percutaneous biopsy
    • Anderson CLV, Acevedo Crespo JC, Lie TH. Risk of pneumothorax not increased by obstructive lung disease in percutaneous biopsy. Chest 1994;105:1705-8.
    • (1994) Chest , vol.105 , pp. 1705-1708
    • Anderson, C.L.V.1    Acevedo Crespo, J.C.2    Lie, T.H.3
  • 80
    • 0024311372 scopus 로고
    • Imaging-directed percutaneous biopsies with a biopsy gun
    • Parker SH, Hopper KD, Yakes WF, et al. Imaging-directed percutaneous biopsies with a biopsy gun. Radiology 1989;171: 663-9.
    • (1989) Radiology , vol.171 , pp. 663-669
    • Parker, S.H.1    Hopper, K.D.2    Yakes, W.F.3
  • 81
    • 0021812948 scopus 로고
    • Rapid cytology to decrease pneumothorax incidence after percutaneous biopsy
    • Johnsrude IS, Silverman JF, Weaver MD, et al. Rapid cytology to decrease pneumothorax incidence after percutaneous biopsy. AJR Am J Roentgenol 1985;144:793-4.
    • (1985) AJR Am J Roentgenol , vol.144 , pp. 793-794
    • Johnsrude, I.S.1    Silverman, J.F.2    Weaver, M.D.3
  • 82
    • 0021959198 scopus 로고
    • Percutaneous needle lung aspiration for diagnosing pneumonitis in the patient with acquired immunodeficiency syndrome (AIDS)
    • Wallace JM, Batra P, Gong H. Percutaneous needle lung aspiration for diagnosing pneumonitis in the patient with acquired immunodeficiency syndrome (AIDS). American Review of Respiratory Diseases 1985;131:389-92.
    • (1985) American Review of Respiratory Diseases , vol.131 , pp. 389-392
    • Wallace, J.M.1    Batra, P.2    Gong, H.3
  • 83
    • 0022345670 scopus 로고
    • Diagnosis of diffuse malignant infiltration of lung (lymphangitic carcinomatosis) by percutaneous fine-needle aspiration biopsy
    • Weisbrod GL, Stoneman HR, Tao LC. Diagnosis of diffuse malignant infiltration of lung (lymphangitic carcinomatosis) by percutaneous fine-needle aspiration biopsy. Journal of the Canadian Association of Radiologists 1985;36:238-43.
    • (1985) Journal of the Canadian Association of Radiologists , vol.36 , pp. 238-243
    • Weisbrod, G.L.1    Stoneman, H.R.2    Tao, L.C.3
  • 84
    • 0023128252 scopus 로고
    • Complications of transthoracic needle biopsy decreased with isobutyl 2-cyanoacrylate: A pilot study
    • Skupin A, Gomez F, Husain M, et al. Complications of transthoracic needle biopsy decreased with isobutyl 2-cyanoacrylate: a pilot study. Ann Thorac Surg 1987;43:406-8.
    • (1987) Ann Thorac Surg , vol.43 , pp. 406-408
    • Skupin, A.1    Gomez, F.2    Husain, M.3
  • 85
    • 0029787293 scopus 로고    scopus 로고
    • Aspiration of a large pneumothorax resulting from transthoracic needle biopsy
    • Yankelevitz DF, Davis SD, Henschke CI. Aspiration of a large pneumothorax resulting from transthoracic needle biopsy. Radiology 1996;200:695-7.
    • (1996) Radiology , vol.200 , pp. 695-697
    • Yankelevitz, D.F.1    Davis, S.D.2    Henschke, C.I.3
  • 86
    • 0018381220 scopus 로고
    • Fatal intrathoracic hemorrhage after percutaneous aspiration lung biopsy
    • Milner LB, Ryan K, Gullo J. Fatal intrathoracic hemorrhage after percutaneous aspiration lung biopsy. AJR Am J Roentgenol 1979; 132:280-1.
    • (1979) AJR Am J Roentgenol , vol.132 , pp. 280-281
    • Milner, L.B.1    Ryan, K.2    Gullo, J.3
  • 87
    • 0025067220 scopus 로고
    • Life-threatening hemorrhage due to percutaneous transthoracic intervention: Importance of the internal mammary artery
    • Glassberg RM, Sussman SK. Life-threatening hemorrhage due to percutaneous transthoracic intervention: importance of the internal mammary artery. AJR Am J Roentgenol 1990;154:47-9.
    • (1990) AJR Am J Roentgenol , vol.154 , pp. 47-49
    • Glassberg, R.M.1    Sussman, S.K.2
  • 88
    • 0024397198 scopus 로고
    • Chest wall implantation of lung cancer after thin-needle aspiration biopsy
    • Seyfer AE, Walsh DS, Graeber GM, et al. Chest wall implantation of lung cancer after thin-needle aspiration biopsy. Ann Thorac Surg 1989;48:284-6.
    • (1989) Ann Thorac Surg , vol.48 , pp. 284-286
    • Seyfer, A.E.1    Walsh, D.S.2    Graeber, G.M.3
  • 90
    • 0014200038 scopus 로고
    • Tranthoracic needle biopsy
    • Nordenstrom B. Tranthoracic needle biopsy. New Engl J Med 1967;276:1081-2.
    • (1967) New Engl J Med , vol.276 , pp. 1081-1082
    • Nordenstrom, B.1
  • 91
    • 0023637433 scopus 로고
    • Fatal systemic arterial air embolism following lung needle aspiration
    • Aberle DR, Gamsu G, Golden JA. Fatal systemic arterial air embolism following lung needle aspiration. Radiology 1987;165: 351-3.
    • (1987) Radiology , vol.165 , pp. 351-353
    • Aberle, D.R.1    Gamsu, G.2    Golden, J.A.3
  • 92
    • 0027732972 scopus 로고
    • A fatal case of cerebral artery gas embolism following fine needle biopsy of the lung
    • Pereira P. A fatal case of cerebral artery gas embolism following fine needle biopsy of the lung. Med J Aust 1993;159:755-7.
    • (1993) Med J Aust , vol.159 , pp. 755-757
    • Pereira, P.1
  • 93
    • 0023574816 scopus 로고
    • Air embolism complicating percutaneous thin needle biopsy of the lung
    • Cianci P, Posin JP, Shimshak RR, et al. Air embolism complicating percutaneous thin needle biopsy of the lung. Chest 1987; 92:749-50.
    • (1987) Chest , vol.92 , pp. 749-750
    • Cianci, P.1    Posin, J.P.2    Shimshak, R.R.3
  • 94
    • 0023697335 scopus 로고
    • Computed tomography of fatal cerebral air embolism following percutaneous aspiration biopsy of the lung
    • Baker BK, Awwad EE. Computed tomography of fatal cerebral air embolism following percutaneous aspiration biopsy of the lung. J Comput Assist Tomogr 1988;12:1082-3.
    • (1988) J Comput Assist Tomogr , vol.12 , pp. 1082-1083
    • Baker, B.K.1    Awwad, E.E.2
  • 95
    • 0024431518 scopus 로고
    • Cerebral air embolism after transthoracic aspiration with a 0.6 mm (23-gauge) needle
    • Omenaas O, Moerkve O, Thomassen L, et al. Cerebral air embolism after transthoracic aspiration with a 0.6 mm (23-gauge) needle. Eur Respir J 1989;2:908-10.
    • (1989) Eur Respir J , vol.2 , pp. 908-910
    • Omenaas, O.1    Moerkve, O.2    Thomassen, L.3
  • 96
    • 0029151202 scopus 로고
    • An unusual case of lung torsion
    • Fogarty JP, Dudek G. An unusual case of lung torsion. Chest 1995;108:575-8.
    • (1995) Chest , vol.108 , pp. 575-578
    • Fogarty, J.P.1    Dudek, G.2
  • 98
    • 0025597016 scopus 로고
    • Misdiagnosis or missed diagnosis? Thoracic actinomycosis and carcinoma on sequential CT-guided lung biopsies
    • Macaulay SE, van Sonnenberg E, Casola G, et al. Misdiagnosis or missed diagnosis? Thoracic actinomycosis and carcinoma on sequential CT-guided lung biopsies. AJR Am J Roentgenol 1990; 155:1183-4.
    • (1990) AJR Am J Roentgenol , vol.155 , pp. 1183-1184
    • Macaulay, S.E.1    Van Sonnenberg, E.2    Casola, G.3
  • 99
    • 0023732020 scopus 로고
    • Percutaneous transthoracic needle biopsy
    • Westcott JL:.Percutaneous transthoracic needle biopsy. Radiology 1988;169:593-601.
    • (1988) Radiology , vol.169 , pp. 593-601
    • Westcott, J.L.1
  • 100
    • 0027397342 scopus 로고
    • Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: Report of 55 cancer patients and metaanalysis of the literature
    • Austin JH, Cohen MB. Value of having a cytopathologist present during percutaneous fine-needle aspiration biopsy of lung: report of 55 cancer patients and metaanalysis of the literature. AJR Am J Roentgenol 1993;160:175-7.
    • (1993) AJR Am J Roentgenol , vol.160 , pp. 175-177
    • Austin, J.H.1    Cohen, M.B.2
  • 101
    • 0029930175 scopus 로고    scopus 로고
    • Transthoracic needle biopsy of mediastinal lymph nodes for staging lung and other cancers
    • Protopapas Z, Westcott JL. Transthoracic needle biopsy of mediastinal lymph nodes for staging lung and other cancers. Radiology 1996;199:489-96.
    • (1996) Radiology , vol.199 , pp. 489-496
    • Protopapas, Z.1    Westcott, J.L.2
  • 102
    • 0025783370 scopus 로고
    • Anterior mediastinal masses: Utility of transthoracic needle biopsy
    • Herman SJ, Holub RV, Weisbrod GL, et al. Anterior mediastinal masses: utility of transthoracic needle biopsy. Radiology 1991; 180:167-70.
    • (1991) Radiology , vol.180 , pp. 167-170
    • Herman, S.J.1    Holub, R.V.2    Weisbrod, G.L.3
  • 103
    • 0029737607 scopus 로고    scopus 로고
    • Image-guided core needle biopsy in malignant lymphoma: Experience with 100 patients that suggests the technique is reliable
    • Ben Yehuda D, Polliack A, Okon E, et al. Image-guided core needle biopsy in malignant lymphoma: experience with 100 patients that suggests the technique is reliable. J Clin Oncol 1996; 14:2431-4.
    • (1996) J Clin Oncol , vol.14 , pp. 2431-2434
    • Ben Yehuda, D.1    Polliack, A.2    Okon, E.3
  • 104
    • 0029758493 scopus 로고    scopus 로고
    • Role of image-guided core needle biopsy in the management of patients with lymphoma
    • Pappa VI, Hussain HK, Reznek RH, et al. Role of image-guided core needle biopsy in the management of patients with lymphoma. J Clin Oncol 1996;14:2427-30.
    • (1996) J Clin Oncol , vol.14 , pp. 2427-2430
    • Pappa, V.I.1    Hussain, H.K.2    Reznek, R.H.3
  • 105
    • 0028954539 scopus 로고
    • Diffuse pleural thickening: Percutaneous CT-guided cutting needle biopsy
    • Scott EM, Marshall TJ, Flower CDR, Stewart S. Diffuse pleural thickening: percutaneous CT-guided cutting needle biopsy. Radiology 1995;194:867-90.
    • (1995) Radiology , vol.194 , pp. 867-890
    • Scott, E.M.1    Marshall, T.J.2    Flower, C.D.R.3    Stewart, S.4
  • 106
    • 0022971160 scopus 로고
    • Correlation between needle biopsy of lung tumors and histopathologic analysis of resected specimens
    • Horrigan TP, Bergin KT. Correlation between needle biopsy of lung tumors and histopathologic analysis of resected specimens. Chest 1986;90:638-40.
    • (1986) Chest , vol.90 , pp. 638-640
    • Horrigan, T.P.1    Bergin, K.T.2
  • 107
    • 0018873805 scopus 로고
    • A study of variability in cytologic diagnoses based on pulmonary aspiration specimens
    • Taft PD, Szyfelbein WM, Greene R. A study of variability in cytologic diagnoses based on pulmonary aspiration specimens. Am J Clin Pathol 1980;73:36-40.
    • (1980) Am J Clin Pathol , vol.73 , pp. 36-40
    • Taft, P.D.1    Szyfelbein, W.M.2    Greene, R.3
  • 108
    • 0019479235 scopus 로고
    • Transthoracic needle aspiration biopsy: Accuracy of cytologic typing of malignant neoplasms
    • Thornbury JR, Burke DP, Naylor B. Transthoracic needle aspiration biopsy: accuracy of cytologic typing of malignant neoplasms. AJR Am J Roentgenol 1981;136:719-24.
    • (1981) AJR Am J Roentgenol , vol.136 , pp. 719-724
    • Thornbury, J.R.1    Burke, D.P.2    Naylor, B.3
  • 110
    • 0025854807 scopus 로고
    • Ultrasound-guided aspiration biopsy of anterior mediastinal masses
    • Tikkakoski T, Lohela P, Leppanen M, et al. Ultrasound-guided aspiration biopsy of anterior mediastinal masses. J Clin Ultrasound 1991;19:209-14.
    • (1991) J Clin Ultrasound , vol.19 , pp. 209-214
    • Tikkakoski, T.1    Lohela, P.2    Leppanen, M.3
  • 112
    • 0342368534 scopus 로고
    • The clinical utility of cytologic typing of lung tumors
    • Raab SS, Silverman JF. The clinical utility of cytologic typing of lung tumors. Diagn Cytopathol 1989;5:174-80.
    • (1989) Diagn Cytopathol , vol.5 , pp. 174-180
    • Raab, S.S.1    Silverman, J.F.2
  • 113
    • 0022595380 scopus 로고
    • Survival in small cell lung carcinoma after surgery
    • Sorensen HR, Lund C, Alstrup P. Survival in small cell lung carcinoma after surgery. Thorax 1986;41:479-81.
    • (1986) Thorax , vol.41 , pp. 479-481
    • Sorensen, H.R.1    Lund, C.2    Alstrup, P.3
  • 114
    • 0023123724 scopus 로고
    • Preliminary experience with a dual cutting edge needle in thoracic percutaneous fine-needle aspiration biopsy
    • Weisbrod GL, Herman SJ, Tao LC. Preliminary experience with a dual cutting edge needle in thoracic percutaneous fine-needle aspiration biopsy. Radiology 1987;163:75-8.
    • (1987) Radiology , vol.163 , pp. 75-78
    • Weisbrod, G.L.1    Herman, S.J.2    Tao, L.C.3
  • 115
    • 0020343933 scopus 로고
    • Thin-needle aspiration biopsy: Methods of increasing the accuracy of a negative prediction
    • Gobien RP, Valicenti JF, Paris BS, et al. Thin-needle aspiration biopsy: methods of increasing the accuracy of a negative prediction. Radiology 1982;145:603-5.
    • (1982) Radiology , vol.145 , pp. 603-605
    • Gobien, R.P.1    Valicenti, J.F.2    Paris, B.S.3
  • 116
    • 0022993156 scopus 로고
    • Interpretation of negative results in fine needle aspiration of discrete pulmonary lesions
    • Winning AJ, McIvor J, Seed WA, et al. Interpretation of negative results in fine needle aspiration of discrete pulmonary lesions. Thorax 1986;41:875-9.
    • (1986) Thorax , vol.41 , pp. 875-879
    • Winning, A.J.1    McIvor, J.2    Seed, W.A.3
  • 117
    • 0021927173 scopus 로고
    • Pulmonary hamartoma: Diagnosis by tranthoracic needle-aspiration biopsy
    • Hamper UM, Khouri NF, Stitik FP, et al. Pulmonary hamartoma: diagnosis by tranthoracic needle-aspiration biopsy. Radiology 1985;155:15-8.
    • (1985) Radiology , vol.155 , pp. 15-18
    • Hamper, U.M.1    Khouri, N.F.2    Stitik, F.P.3
  • 118
    • 0024337205 scopus 로고
    • The aspiration cytology of pulmonary hamartomas
    • Dunbar F, Leiman G. The aspiration cytology of pulmonary hamartomas. Diagn Cytopathol 1989;5:174-80.
    • (1989) Diagn Cytopathol , vol.5 , pp. 174-180
    • Dunbar, F.1    Leiman, G.2
  • 119
    • 0030051348 scopus 로고    scopus 로고
    • Transthoracic needle biopsy with a coaxially-placed 20-gauge automated cutting needle: Results in 122 patients
    • Klein JS, Salomon G, Stewart EA. Transthoracic needle biopsy with a coaxially-placed 20-gauge automated cutting needle: results in 122 patients. Radiology 1996;198:715-20.
    • (1996) Radiology , vol.198 , pp. 715-720
    • Klein, J.S.1    Salomon, G.2    Stewart, E.A.3
  • 120
    • 22644448256 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy: A comparison between automated cutting biopsy gun and fine needle aspiration
    • Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T. CT-guided transthoracic needle biopsy: A comparison between automated cutting biopsy gun and fine needle aspiration. Clin Radiol 1996;51:503-6.
    • (1996) Clin Radiol , vol.51 , pp. 503-506
    • Arakawa, H.1    Nakajima, Y.2    Kurihara, Y.3    Niimi, H.4    Ishikawa, T.5
  • 121
    • 0027463920 scopus 로고
    • Coaxial percutaneous biopsy technique with automated biopsy devices: Value in improving accuracy and negative predictive value
    • Moulton JS, Moore PT. Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value. Radiology 1993;186:515-22.
    • (1993) Radiology , vol.186 , pp. 515-522
    • Moulton, J.S.1    Moore, P.T.2
  • 122
    • 0022639775 scopus 로고
    • The clinical outcome of needle aspiration of the lung when lung cancer is not diagnosed
    • Calhoun P, Feldman PS, Arnstrong P, et al. The clinical outcome of needle aspiration of the lung when lung cancer is not diagnosed. Ann Thorac Surg 1986;41:592-6.
    • (1986) Ann Thorac Surg , vol.41 , pp. 592-596
    • Calhoun, P.1    Feldman, P.S.2    Arnstrong, P.3
  • 123
    • 0031030126 scopus 로고    scopus 로고
    • Transthoracic needle biopsy of small pulmonary nodules
    • Westcott JL, Rao N, Colley DP. Transthoracic needle biopsy of small pulmonary nodules. Radiology 1997;202:97-103.
    • (1997) Radiology , vol.202 , pp. 97-103
    • Westcott, J.L.1    Rao, N.2    Colley, D.P.3
  • 124
    • 0029970058 scopus 로고    scopus 로고
    • Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: Comparison of small and large pulmonary nodules
    • Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 1996;167:105-9.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 105-109
    • Li, H.1    Boiselle, P.M.2    Shepard, J.O.3    Trotman-Dickenson, B.4    McLoud, T.C.5
  • 125
    • 0018384981 scopus 로고
    • Etiologic diagnosis of focal pulmonary infection in immunocompromised patients by fluoroscopically guided percutaneous needle aspiration
    • Castellino RA, Blank N. Etiologic diagnosis of focal pulmonary infection in immunocompromised patients by fluoroscopically guided percutaneous needle aspiration. Radiology 1979;132:563-7.
    • (1979) Radiology , vol.132 , pp. 563-567
    • Castellino, R.A.1    Blank, N.2
  • 126
    • 0025848219 scopus 로고
    • Lung abscesses: Ultrasound examination and US-guided transthoracic aspiration
    • Yang PC, Luh KT, Lee YC, et al. Lung abscesses: ultrasound examination and US-guided transthoracic aspiration. Radiology 1991;180:171-5.
    • (1991) Radiology , vol.180 , pp. 171-175
    • Yang, P.C.1    Luh, K.T.2    Lee, Y.C.3
  • 127
    • 0025762897 scopus 로고
    • Percutaneous needle aspiration of neonatal lung abscesses
    • Lee SK, Morris RF, Cramer B. Percutaneous needle aspiration of neonatal lung abscesses. Pediatr Radiol 1991;21:254-7.
    • (1991) Pediatr Radiol , vol.21 , pp. 254-257
    • Lee, S.K.1    Morris, R.F.2    Cramer, B.3
  • 128
    • 0025141483 scopus 로고
    • Yield of percutaneous needle lung aspiration in lung abscess
    • Grinan NP, Lucena FM, Romero JV, et al. Yield of percutaneous needle lung aspiration in lung abscess. Chest 1990;97:69-74.
    • (1990) Chest , vol.97 , pp. 69-74
    • Grinan, N.P.1    Lucena, F.M.2    Romero, J.V.3
  • 129
    • 0023158481 scopus 로고
    • Pulmonary lymphangitic spread of carcinoma: Appearance on CT scans
    • Stein MG, Mayo J, Muller N, et al. Pulmonary lymphangitic spread of carcinoma: appearance on CT scans. Radiology 1987; 162:371-5.
    • (1987) Radiology , vol.162 , pp. 371-375
    • Stein, M.G.1    Mayo, J.2    Muller, N.3
  • 131
    • 0000289686 scopus 로고    scopus 로고
    • Cost analysis of competing strategies for evaluating and treating solitary pulmonary nodules
    • Yankelevitz DF, Henschke CI, Altorki NK. Cost analysis of competing strategies for evaluating and treating solitary pulmonary nodules [Abstract]. Radiology 1996;201(suppl):269.
    • (1996) Radiology , vol.201 , Issue.SUPPL. , pp. 269
    • Yankelevitz, D.F.1    Henschke, C.I.2    Altorki, N.K.3
  • 132
    • 0027366755 scopus 로고
    • The utility of fiberoptic bronchoscopy in the evaluation of the solitary pulmonary nodule
    • Torrington KG, Kern JD. The utility of fiberoptic bronchoscopy in the evaluation of the solitary pulmonary nodule. Chest 1993; 104:1021-24.
    • (1993) Chest , vol.104 , pp. 1021-1024
    • Torrington, K.G.1    Kern, J.D.2
  • 133
    • 0026335317 scopus 로고
    • Bronchus sign on peripheral carcinoma of the lung: Value in predicting results of transbronchial biopsy
    • Gaeta M, Pandolfo I, Volta S, Russi EG, Baritorom G, Girone G. Bronchus sign on peripheral carcinoma of the lung: value in predicting results of transbronchial biopsy. AJR Am J Roentgenol 1991;157:1181-5.
    • (1991) AJR Am J Roentgenol , vol.157 , pp. 1181-1185
    • Gaeta, M.1    Pandolfo, I.2    Volta, S.3    Russi, E.G.4    Baritorom, G.5    Girone, G.6
  • 134
    • 0026411024 scopus 로고
    • Diagnosis of mediastinal mycobacterial lymphadenopathy by transbronchial needle aspiration
    • Baron KM, Aranda CP. Diagnosis of mediastinal mycobacterial lymphadenopathy by transbronchial needle aspiration. Chest 1991;100:1723-4.
    • (1991) Chest , vol.100 , pp. 1723-1724
    • Baron, K.M.1    Aranda, C.P.2
  • 136
    • 0022592661 scopus 로고
    • Diagnosis and treatment of a bronchogenic cyst using transbronchial needle aspiration
    • Schwartz AR, Fishman EK, Wang KP. Diagnosis and treatment of a bronchogenic cyst using transbronchial needle aspiration. Thorax 1986;41:326-7.
    • (1986) Thorax , vol.41 , pp. 326-327
    • Schwartz, A.R.1    Fishman, E.K.2    Wang, K.P.3
  • 137
    • 0029738429 scopus 로고    scopus 로고
    • Endoscopic ultrasonography and real-time guided fine-needle aspiration biopsy of solid lesions of the mediastinum suspected of malignancy
    • Pederson BH, Vilmann P, Folke K, et al. Endoscopic ultrasonography and real-time guided fine-needle aspiration biopsy of solid lesions of the mediastinum suspected of malignancy. Chest 1996; 110:539-44.
    • (1996) Chest , vol.110 , pp. 539-544
    • Pederson, B.H.1    Vilmann, P.2    Folke, K.3
  • 138
    • 0028049055 scopus 로고
    • Preoperative staging of non-small cell lung cancer: Transesophageal US-guided fine-needle aspiration biopsy of mediastinal lymph nodes
    • Wiersema MJ, Kochman ML, Cramer HM, Wiersema LM. Preoperative staging of non-small cell lung cancer: transesophageal US-guided fine-needle aspiration biopsy of mediastinal lymph nodes. Radiology 1994;190:239-42.
    • (1994) Radiology , vol.190 , pp. 239-242
    • Wiersema, M.J.1    Kochman, M.L.2    Cramer, H.M.3    Wiersema, L.M.4
  • 139
    • 0018649602 scopus 로고
    • Diagnostic accuracy in peripheral lung lesions: Factors predicting success with flexible fiberoptic bronchoscopy
    • Radke JR, Conway WA, Eyler WR, Kvale PA. Diagnostic accuracy in peripheral lung lesions: factors predicting success with flexible fiberoptic bronchoscopy. Chest 1979;76:176-9.
    • (1979) Chest , vol.76 , pp. 176-179
    • Radke, J.R.1    Conway, W.A.2    Eyler, W.R.3    Kvale, P.A.4
  • 140
    • 0028222228 scopus 로고
    • Interbronchoscopist variability in the diagnosis of lung cancer by flexible bronchoscopy
    • Minami H, Ando Y, Nomura F, Sakai S, Shimomata K. Interbronchoscopist variability in the diagnosis of lung cancer by flexible bronchoscopy. Chest 1994;105:1658-62.
    • (1994) Chest , vol.105 , pp. 1658-1662
    • Minami, H.1    Ando, Y.2    Nomura, F.3    Sakai, S.4    Shimomata, K.5
  • 141
    • 0029018240 scopus 로고
    • Integration of transbronchial and percutaneous approach in the diagnosis of peripheral pulmonary nodules or masses. Experience with 1027 consecutive cases
    • Gasparini S, Ferretti M, Bichi Secchi E, Baldelli S, Zuccatosta L, Gusella P. Integration of transbronchial and percutaneous approach in the diagnosis of peripheral pulmonary nodules or masses. Experience with 1027 consecutive cases. Chest 1995; 108:131-8.
    • (1995) Chest , vol.108 , pp. 131-138
    • Gasparini, S.1    Ferretti, M.2    Bichi Secchi, E.3    Baldelli, S.4    Zuccatosta, L.5    Gusella, P.6
  • 142
    • 0028874409 scopus 로고
    • Diagnosing the indeterminate pulmonary nodule: Percutaneous biopsy versus thoracoscopy
    • Mitruka S, Landreneau RJ, Mack MJ et al. Diagnosing the indeterminate pulmonary nodule: Percutaneous biopsy versus thoracoscopy. Surgery 1995;118:676-84.
    • (1995) Surgery , vol.118 , pp. 676-684
    • Mitruka, S.1    Landreneau, R.J.2    Mack, M.J.3
  • 143
    • 0027448819 scopus 로고
    • Limited resection of bronchogenic carcinoma in the patient with impaired pulmonary function
    • Miller JI Jr. Limited resection of bronchogenic carcinoma in the patient with impaired pulmonary function. Ann Thorac Surg 1993;56:769-71.
    • (1993) Ann Thorac Surg , vol.56 , pp. 769-771
    • Miller J.I., Jr.1
  • 144
    • 0027366435 scopus 로고
    • Video-assisted thoracoscopy and the staging of lung cancer
    • Wain JC. Video-assisted thoracoscopy and the staging of lung cancer. Ann Thorac Surg 1993;56:776-8.
    • (1993) Ann Thorac Surg , vol.56 , pp. 776-778
    • Wain, J.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.