Volumn 9, Issue 6, 1997, Pages 361-365

Choice of instrument for vaginal delivery

Author keywords

[No Author keywords available]

Indexed keywords

COMPETENCE; HUMAN; INSTRUMENTAL DELIVERY; MEDICAL DECISION MAKING; PRIORITY JOURNAL; REVIEW; SAFETY; TREATMENT PLANNING; VAGINAL DELIVERY;

EID: 0030680224     PISSN: 1040872X     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001703-199712000-00005     Document Type: Review
Times cited : (11)

References (40)
  • 1
    • 0027995449 scopus 로고
    • Worldwide survey of instrumental delivery
    • Hillier C, Johanson RB: Worldwide survey of instrumental delivery. Int J Obstet Gynecol 1994, 47:109-114.
    • (1994) Int J Obstet Gynecol , vol.47 , pp. 109-114
    • Hillier, C.1    Johanson, R.B.2
  • 3
    • 0029837046 scopus 로고    scopus 로고
    • Forceps and vacuum delivery: A survey of North American residency programs
    • Bofill JA, Perry KG, Roberts WE, Morrison JC: Forceps and vacuum delivery: a survey of North American residency programs. Obstet Gynecol 1996, 88:622-625. Interesting current view of US training programmes.
    • (1996) Obstet Gynecol , vol.88 , pp. 622-625
    • Bofill, J.A.1    Perry, K.G.2    Roberts, W.E.3    Morrison, J.C.4
  • 4
    • 0030019622 scopus 로고    scopus 로고
    • An analysis of recent trends in vacuum extraction and forceps delivery in the United Kingdom
    • Meniru GI: An analysis of recent trends in vacuum extraction and forceps delivery in the United Kingdom. Br J Obstet Gynaecol 1996, 103:168-170. Interesting analysis of trends in assisted delivery in the UK.
    • (1996) Br J Obstet Gynaecol , vol.103 , pp. 168-170
    • Meniru, G.I.1
  • 6
    • 0029947735 scopus 로고    scopus 로고
    • Choice and instrumental delivery
    • Drife JO: Choice and instrumental delivery. Br J Obstet Gynaecol 1996, 103:608-611.
    • (1996) Br J Obstet Gynaecol , vol.103 , pp. 608-611
    • Drife, J.O.1
  • 7
    • 0030248343 scopus 로고    scopus 로고
    • Large differences in obstetrical intervention rates among Dutch hospitals, even after adjustment for population differences
    • Elferink-Stinkens PM, Brand R, le Cessie S, Van Hemel OJS: Large differences in obstetrical intervention rates among Dutch hospitals, even after adjustment for population differences. Eur J Obstet Gynecol Reprod Biol 1996, 68:97-103.
    • (1996) Eur J Obstet Gynecol Reprod Biol , vol.68 , pp. 97-103
    • Elferink-Stinkens, P.M.1    Brand, R.2    Le Cessie, S.3    Van Hemel, O.J.S.4
  • 8
    • 0029612306 scopus 로고    scopus 로고
    • Labour and delivery of 'normal' primiparous women: Analysis of routinely collected data
    • Middle C, Macfarlane A: Labour and delivery of 'normal' primiparous women: analysis of routinely collected data. Br J Obstet Gynaecol 1996, 102:970-977. Important analysis of wide variations in intervention rates in the UK.
    • (1996) Br J Obstet Gynaecol , vol.102 , pp. 970-977
    • Middle, C.1    Macfarlane, A.2
  • 9
    • 0028902982 scopus 로고
    • Variation in caesarean and instrumental delivery rates in New Zealand hospitals
    • Johnson N, Ansell D: Variation in caesarean and instrumental delivery rates in New Zealand hospitals. Aust NZ J Obstet Gynecol 1995, 35:6-11.
    • (1995) Aust NZ J Obstet Gynecol , vol.35 , pp. 6-11
    • Johnson, N.1    Ansell, D.2
  • 10
    • 0025316820 scopus 로고
    • International differences in the use of obstetric intervention
    • Notzon FC: International differences in the use of obstetric intervention. JAMA 1990, 263:3286-3291.
    • (1990) JAMA , vol.263 , pp. 3286-3291
    • Notzon, F.C.1
  • 12
    • 0029995679 scopus 로고    scopus 로고
    • A randomized prospective trial of the obstetric forceps versus the M-cup vacuum extractor
    • Bofill JA, Rust OA, Schorr SJ, Brown RC, Martin RW, Morrison JC: A randomized prospective trial of the obstetric forceps versus the M-cup vacuum extractor. Am J Obstet Gynecol 1996, 175:1325-1330. Well-designed, substantial randomized controlled trial showing the benefits of vacuum extraction.
    • (1996) Am J Obstet Gynecol , vol.175 , pp. 1325-1330
    • Bofill, J.A.1    Rust, O.A.2    Schorr, S.J.3    Brown, R.C.4    Martin, R.W.5    Morrison, J.C.6
  • 13
    • 0003354871 scopus 로고    scopus 로고
    • Vacuum extraction vs forceps delivery
    • updated 3 June 1997. Edited by Neilson JP, Crowther CA, Jodnett ED, Hofmeyr GJ, Keirse MJNC. Available in The Cochrane Library (database on disk and CDROM). The Cochrane Collaboration; Oxford: Update Software
    • Johanson RB, Menon V: Vacuum extraction vs forceps delivery. In Pregnancy and Childbirth Module of the Cochrane Database of Systematic Reviews (updated 3 June 1997). Edited by Neilson JP, Crowther CA, Jodnett ED, Hofmeyr GJ, Keirse MJNC. Available in The Cochrane Library (database on disk and CDROM). The Cochrane Collaboration; Issue 3. Oxford: Update Software; 1997. Most up-to-date meta-analysis of controlled trials of forceps and vacuum extraction.
    • (1997) Pregnancy and Childbirth Module of the Cochrane Database of Systematic Reviews , Issue.3
    • Johanson, R.B.1    Menon, V.2
  • 15
    • 0028265026 scopus 로고
    • Third degree obstetric anal sphincter tears: Risk factors and outcome of primary repair
    • Sultan AH, Kamm MA, Hudson CN, Bartram CI: Third degree obstetric anal sphincter tears: risk factors and outcome of primary repair. BMJ 1994, 308:887-891.
    • (1994) BMJ , vol.308 , pp. 887-891
    • Sultan, A.H.1    Kamm, M.A.2    Hudson, C.N.3    Bartram, C.I.4
  • 16
    • 0030054366 scopus 로고    scopus 로고
    • Birth by vacuum extraction: Neonatal outcome
    • Vacca A: Birth by vacuum extraction: neonatal outcome. J Paediatr Child Health 1996, 32:204-206.
    • (1996) J Paediatr Child Health , vol.32 , pp. 204-206
    • Vacca, A.1
  • 17
    • 0028400518 scopus 로고
    • Subgaleal hemorrhage in the newborn infant associated with silicone elastomer vacuum extractor
    • Florentino-Pineda I, Ezhuthacan SG, Sineni LG, Kumer SP: Subgaleal hemorrhage in the newborn infant associated with silicone elastomer vacuum extractor. J Perinat 1994, 14:95-100.
    • (1994) J Perinat , vol.14 , pp. 95-100
    • Florentino-Pineda, I.1    Ezhuthacan, S.G.2    Sineni, L.G.3    Kumer, S.P.4
  • 18
    • 0018345473 scopus 로고
    • Fetal cranial injuries related to the delivery with the Malmström vacuum extractor
    • Plauche WC: Fetal cranial injuries related to the delivery with the Malmström vacuum extractor. Obstet Gynecol 1979, 53:750-757.
    • (1979) Obstet Gynecol , vol.53 , pp. 750-757
    • Plauche, W.C.1
  • 19
    • 0031080834 scopus 로고    scopus 로고
    • Vacuum extraction: Does duration predict scalp injury?
    • Teng FY, Sayre JW: Vacuum extraction: does duration predict scalp injury? Obstet Gynecol 1997, 89:281-285.
    • (1997) Obstet Gynecol , vol.89 , pp. 281-285
    • Teng, F.Y.1    Sayre, J.W.2
  • 22
    • 0027463840 scopus 로고
    • CT demonstration of intracranial haemorrhage in term newborn following vacuum extractor delivery
    • Avrahami E, Frishman E, Minz M: CT demonstration of intracranial haemorrhage in term newborn following vacuum extractor delivery. Neuroradiology 1993, 35:107-108.
    • (1993) Neuroradiology , vol.35 , pp. 107-108
    • Avrahami, E.1    Frishman, E.2    Minz, M.3
  • 23
    • 0028242981 scopus 로고
    • Incidence of neonatal sixth nerve palsy in relation to mode of delivery
    • Galbraith RS: Incidence of neonatal sixth nerve palsy in relation to mode of delivery. Am J Obstet Gynecol 1994, 170:1158-1159.
    • (1994) Am J Obstet Gynecol , vol.170 , pp. 1158-1159
    • Galbraith, R.S.1
  • 24
    • 0019519076 scopus 로고
    • Traumatic intracranial haemorrhage in firstborn infants and delivery with obstetric forceps
    • O'Driscoll K, Meagher D, MacDonald D, Geoghegan F: Traumatic intracranial haemorrhage in firstborn infants and delivery with obstetric forceps. Br J Obstet Gynaecol 1981, 88:577-581.
    • (1981) Br J Obstet Gynaecol , vol.88 , pp. 577-581
    • O'Driscoll, K.1    Meagher, D.2    MacDonald, D.3    Geoghegan, F.4
  • 25
    • 0029056889 scopus 로고
    • High cervical spinal cord injury in neonates delivered with forceps: Report of 15 cases
    • Menticoglou SM, Perlman M, Manning FA: High cervical spinal cord injury in neonates delivered with forceps: report of 15 cases. Obstet Gynecol 1995, 86:589-594.
    • (1995) Obstet Gynecol , vol.86 , pp. 589-594
    • Menticoglou, S.M.1    Perlman, M.2    Manning, F.A.3
  • 28
    • 0027309376 scopus 로고
    • A randomised prospective study comparing the new vacuum extractor policy with forceps delivery
    • Johanson RB, Rice C, Doyle M, Arthur J, Anyanwu L, Ibrahim J et al.: A randomised prospective study comparing the new vacuum extractor policy with forceps delivery. Br J Obstet Gynaecol 1993, 100:524-530.
    • (1993) Br J Obstet Gynaecol , vol.100 , pp. 524-530
    • Johanson, R.B.1    Rice, C.2    Doyle, M.3    Arthur, J.4    Anyanwu, L.5    Ibrahim, J.6
  • 29
    • 0028912820 scopus 로고
    • Vacuum extraction of preterm infants with birth weights of 1,500-2,499 grams
    • Morales R, Adair CD, Sanchez-Ramos L, Gaudier FL Vacuum extraction of preterm infants with birth weights of 1,500-2,499 grams. J Reprod Med 1995, 40:127-130.
    • (1995) J Reprod Med , vol.40 , pp. 127-130
    • Morales, R.1    Adair, C.D.2    Sanchez-Ramos, L.3    Gaudier, F.L.4
  • 30
    • 0017896438 scopus 로고
    • Fetal haemorrhage, complication of vacuum extractor after fetal blood sampling
    • Roberts IF, Stone M: Fetal haemorrhage, complication of vacuum extractor after fetal blood sampling. Am J Obstet Gynecol 1978, 132:109.
    • (1978) Am J Obstet Gynecol , vol.132 , pp. 109
    • Roberts, I.F.1    Stone, M.2
  • 31
    • 0014869549 scopus 로고
    • Vacuum extraction after fetal blood sampling
    • Lee KH: Vacuum extraction after fetal blood sampling. Aust NZ J Obstet Gynecol 1970, 10:205.
    • (1970) Aust NZ J Obstet Gynecol , vol.10 , pp. 205
    • Lee, K.H.1
  • 33
    • 0026654043 scopus 로고
    • A randomised prospective study comparing delivery with metal and silicone rubber vacuum extractor cups
    • Chenoy R, Johanson RB: A randomised prospective study comparing delivery with metal and silicone rubber vacuum extractor cups. Br J Obstet Gynaecol 1992, 99:360-363.
    • (1992) Br J Obstet Gynaecol , vol.99 , pp. 360-363
    • Chenoy, R.1    Johanson, R.B.2
  • 34
    • 0027412495 scopus 로고
    • The effect of artificial caput on performance of vacuum extractors
    • Muise KL, Duchon MA, Brown RH: The effect of artificial caput on performance of vacuum extractors. Obstet Gynecol 1993, 81:170-173.
    • (1993) Obstet Gynecol , vol.81 , pp. 170-173
    • Muise, K.L.1    Duchon, M.A.2    Brown, R.H.3
  • 35
    • 0030859284 scopus 로고    scopus 로고
    • A random controlled trial of two different vacuum extractor pumps: New foot pump and electric pump
    • Gabrawi E, Johanson RB, Jones P: A random controlled trial of two different vacuum extractor pumps: new foot pump and electric pump. J Obstet Gynecol 1997, 17:325-327.
    • (1997) J Obstet Gynecol , vol.17 , pp. 325-327
    • Gabrawi, E.1    Johanson, R.B.2    Jones, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.