메뉴 건너뛰기




Volumn 2, Issue , 1997, Pages 898-903

Effect of operational amplifier parameters on the performance of feedback structures with thermoresistive sensors

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG INTEGRATED CIRCUITS; FEEDBACK AMPLIFIERS; FLOW OF FLUIDS; BRIDGE CIRCUITS; ELECTRIC NETWORK ANALYSIS; ELECTRIC NETWORK PARAMETERS; FEEDBACK; OPERATIONAL AMPLIFIERS;

EID: 0030673238     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMTC.1997.610254     Document Type: Conference Paper
Times cited : (9)

References (9)
  • 6
    • 0002949766 scopus 로고
    • Feedback control theory for constant-temperature hot-wire anemometer
    • P. Freymuth, Feedback Control Theory for Constant-Temperature Hot-Wire Anemometer, The Review of Scientific Instruments, vol. 38, no. 5, pp. 677-681, 1967.
    • (1967) The Review of Scientific Instruments , vol.38 , Issue.5 , pp. 677-681
    • Freymuth, P.1
  • 7
    • 0346319030 scopus 로고
    • A study of the constant-temperature hot-wire anemometer
    • A. Perry and G.L. Morrison, A Study of the Constant-Temperature Hot-Wire Anemometer, J. Fluid. Mech., vol. 47, part 3, pp. 577-599, 1971.
    • (1971) J. Fluid. Mech , vol.47 , pp. 577-599
    • Perry, A.1    Morrison, G.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.