메뉴 건너뛰기




Volumn 10, Issue 4-5, 1997, Pages 160-164

Methods for assessing accuracy and reliability in functional MRI

Author keywords

Functional MRI; Reliability; ROC analysis; Statistical testing

Indexed keywords

ANALYTIC METHOD; ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC APPROACH ROUTE; NOISE REDUCTION; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; RELIABILITY; STATISTICAL ANALYSIS;

EID: 0030669660     PISSN: 09523480     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1099-1492(199706/08)10:4/5<160::AID-NBM458>3.0.CO;2-A     Document Type: Article
Times cited : (39)

References (30)
  • 1
    • 0025096481 scopus 로고
    • Magnetic resonance imaging of blood vessels at high fields: In vivo and in vitro measurements and image simulation
    • Ogawa, S. and Lee, T.-M. Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation. Magn. Reson. Med. 16, 9-18 (1990).
    • (1990) Magn. Reson. Med. , vol.16 , pp. 9-18
    • Ogawa, S.1    Lee, T.-M.2
  • 2
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa, S., Lee, T.-M., Kay, A. R. and Tank, D. W. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc. Natl Acad. Sci. USA 87, 9868-9872 (1990).
    • (1990) Proc. Natl Acad. Sci. USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.-M.2    Kay, A.R.3    Tank, D.W.4
  • 3
    • 0025336246 scopus 로고
    • Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
    • Ogawa, S., Lee, T-M., Nayak, A. S. and Glynn, P. Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields. Magn. Reson. Med. 14, 68-78 (1990).
    • (1990) Magn. Reson. Med. , vol.14 , pp. 68-78
    • Ogawa, S.1    Lee, T.-M.2    Nayak, A.S.3    Glynn, P.4
  • 4
    • 0026754226 scopus 로고
    • Intrinsic signal changes accompanying sensory stimulation: Functional brain mapping with magnetic resonance imaging
    • Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S.-G., Merkle, H. and Ugurbil, K. Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. Proc. Natl Acad. Sci. USA 89, 5951-5955 (1992).
    • (1992) Proc. Natl Acad. Sci. USA , vol.89 , pp. 5951-5955
    • Ogawa, S.1    Tank, D.W.2    Menon, R.3    Ellermann, J.M.4    Kim, S.-G.5    Merkle, H.6    Ugurbil, K.7
  • 5
    • 0029151256 scopus 로고
    • Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
    • Kim, S. G. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn. Reson. Med. 34, 293-301 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 293-301
    • Kim, S.G.1
  • 7
    • 0027936294 scopus 로고
    • Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency
    • Edelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V., Nobre, A C., Mesulam, M. M. and Warach, S. Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency. Radiology 192, 513-520 (1994).
    • (1994) Radiology , vol.192 , pp. 513-520
    • Edelman, R.R.1    Siewert, B.2    Darby, D.G.3    Thangaraj, V.4    Nobre, A.C.5    Mesulam, M.M.6    Warach, S.7
  • 8
    • 0027288454 scopus 로고
    • Processing strategies for time-course data sets in functional MRI of the human brain
    • Bandettini, P. A., Jesmanowicz, A., Wong, E. C. and Hyde, J. S. Processing strategies for time-course data sets in functional MRI of the human brain. Magn. Reson. Med. 30, 161-173 (1993).
    • (1993) Magn. Reson. Med. , vol.30 , pp. 161-173
    • Bandettini, P.A.1    Jesmanowicz, A.2    Wong, E.C.3    Hyde, J.S.4
  • 9
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and reslicing PET images
    • Woods, R. P., Mazziotta, J. C. and Cherry, S. R. Rapid automated algorithm for aligning and reslicing PET images. J. Comput. Assist. Tomogr. 16, 620-633 (1992).
    • (1992) J. Comput. Assist. Tomogr. , vol.16 , pp. 620-633
    • Woods, R.P.1    Mazziotta, J.C.2    Cherry, S.R.3
  • 13
    • 0028285121 scopus 로고
    • Reduction of physiological noise in functional MRI using navigator echo
    • Hu, X. and Kim, S.-G. Reduction of physiological noise in functional MRI using navigator echo. Magn. Reson. Med. 31, 495-503 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , pp. 495-503
    • Hu, X.1    Kim, S.-G.2
  • 14
    • 0029118783 scopus 로고
    • Retrospective estimation and correction of physiological fluctuation in functional MRI
    • Hu, X., Le, T. H., Parrish, T. and Erhard, P. Retrospective estimation and correction of physiological fluctuation in functional MRI. Magn. Reson. Med. 34, 201-212 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 201-212
    • Hu, X.1    Le, T.H.2    Parrish, T.3    Erhard, P.4
  • 15
    • 0008913870 scopus 로고    scopus 로고
    • Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data
    • Le, T. H. and Hu, X. Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data. Magn. Reson. Med. 35, 290-298 (1996).
    • (1996) Magn. Reson. Med. , vol.35 , pp. 290-298
    • Le, T.H.1    Hu, X.2
  • 16
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • Metz, C. E. Basic principles of ROC analysis. Semin. Nucl. Med. 8, 283-298 (1978).
    • (1978) Semin. Nucl. Med. , vol.8 , pp. 283-298
    • Metz, C.E.1
  • 17
    • 0029025207 scopus 로고
    • An ROC approach for evaluating functional brain MR imaging and postprocessing protocols
    • Constable, R. T., Skudlarski, P. and Gore, J. C. An ROC approach for evaluating functional brain MR imaging and postprocessing protocols. Magn. Reson. Med. 34, 57-64 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 57-64
    • Constable, R.T.1    Skudlarski, P.2    Gore, J.C.3
  • 18
    • 0029858643 scopus 로고    scopus 로고
    • ROC methods for evaluation of fMRI techniques
    • Sorenson, J. A. and Wang, X. ROC methods for evaluation of fMRI techniques. Magn. Reson. Med. 36, 737-744 (1996).
    • (1996) Magn. Reson. Med. , vol.36 , pp. 737-744
    • Sorenson, J.A.1    Wang, X.2
  • 19
    • 84973587732 scopus 로고
    • A coefficient of agreement for nominal scales
    • Cohen, J. A coefficient of agreement for nominal scales. Educ. Psychol. Meas. 20, 37-46 (1960).
    • (1960) Educ. Psychol. Meas. , vol.20 , pp. 37-46
    • Cohen, J.1
  • 20
    • 3343019470 scopus 로고
    • Measuring nominal scale agreement among many raters
    • Fleiss, J. H. Measuring nominal scale agreement among many raters. Pyschol. Bull. 76, 378-382 (1971).
    • (1971) Pyschol. Bull. , vol.76 , pp. 378-382
    • Fleiss, J.H.1
  • 24
    • 38649132833 scopus 로고
    • Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals-rating-method data
    • Dorfman, D. D. and Alf, E. Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals-rating-method data. J. Math. Psychol. 6, 487-496 (1969).
    • (1969) J. Math. Psychol. , vol.6 , pp. 487-496
    • Dorfman, D.D.1    Alf, E.2
  • 25
    • 0001126268 scopus 로고
    • Some aspects of ROC curvefitting: Normal and logistic models
    • Grey, D. R. and Morgan, B. J. T. Some aspects of ROC curvefitting: normal and logistic models. J. Math. Psychol. 9, 128-139 (1972).
    • (1972) J. Math. Psychol. , vol.9 , pp. 128-139
    • Grey, D.R.1    Morgan, B.J.T.2
  • 26
    • 0000861950 scopus 로고
    • Implications of latency data for threshold and nonthreshold models for signal detection
    • Thomas, E. A. C. and Myers, J. L. Implications of latency data for threshold and nonthreshold models for signal detection. J. Math. Psychol. 9, 253-285 (1972).
    • (1972) J. Math. Psychol. , vol.9 , pp. 253-285
    • Thomas, E.A.C.1    Myers, J.L.2
  • 27
    • 58149412516 scopus 로고
    • Weighted kappa: Nominal scale agreement with provision for scaled disagreement or partial credit
    • Cohen, J. Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol. Bull. 70, 213-220 (1968).
    • (1968) Psychol. Bull. , vol.70 , pp. 213-220
    • Cohen, J.1
  • 29
    • 0024370623 scopus 로고
    • Analyzing a portion of the ROC curve
    • McLish, D. K. Analyzing a portion of the ROC curve. Med. Decis. Making 9, 190-195 (1989).
    • (1989) Med. Decis. Making , vol.9 , pp. 190-195
    • McLish, D.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.