메뉴 건너뛰기




Volumn 43, Issue 11, 1997, Pages 2164-2168

Comparison of NCEP performance specifications for triglycerides, HDL-, and LDL-cholesterol with operating specifications based on NCEP clinical and analytical goals

Author keywords

[No Author keywords available]

Indexed keywords

HIGH DENSITY LIPOPROTEIN CHOLESTEROL; LOW DENSITY LIPOPROTEIN CHOLESTEROL; TRIACYLGLYCEROL;

EID: 0030665101     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1093/clinchem/43.11.2164     Document Type: Article
Times cited : (8)

References (13)
  • 1
    • 0023728740 scopus 로고
    • Current status of blood cholesterol measurement in clinical laboratories in the United States
    • National Cholesterol Education Program Laboratory Standardization Panel. Current status of blood cholesterol measurement in clinical laboratories in the United States. Clin Chem 1988;34:193-201.
    • (1988) Clin Chem , vol.34 , pp. 193-201
  • 2
    • 0025814770 scopus 로고
    • Laboratory process specifications for assuring quality in the US National Cholesterol Education Program
    • Westgard JO, Hyltoft Petersen P, Wiebe DA. Laboratory process specifications for assuring quality in the US National Cholesterol Education Program. Clin Chem 1991;37:656-61.
    • (1991) Clin Chem , vol.37 , pp. 656-661
    • Westgard, J.O.1    Hyltoft Petersen, P.2    Wiebe, D.A.3
  • 3
    • 0026348763 scopus 로고
    • Cholesterol operational process specifications for assuring quality required by CLIA proficiency testing
    • Westgard JO, Wiebe DA. Cholesterol operational process specifications for assuring quality required by CLIA proficiency testing. Clin Chem 1991;37:1938-44.
    • (1991) Clin Chem , vol.37 , pp. 1938-1944
    • Westgard, J.O.1    Wiebe, D.A.2
  • 4
    • 0027161058 scopus 로고
    • Cholesterol - α model system to relate medical needs with analytical performance
    • Wiebe DA, Westgard JO. Cholesterol - α model system to relate medical needs with analytical performance. Clin Chem 1993;39:1504-13.
    • (1993) Clin Chem , vol.39 , pp. 1504-1513
    • Wiebe, D.A.1    Westgard, J.O.2
  • 5
    • 0028970546 scopus 로고
    • National Cholesterol Education Program recommendations for measurement of low-density lipoprotein cholesterol: Executive summary
    • Bachorik PS, Ross JW, for the NCEP Working Group on Lipoprotein Measurement. National Cholesterol Education Program recommendations for measurement of low-density lipoprotein cholesterol: executive summary. Clin Chem 1995;41:1414-20.
    • (1995) Clin Chem , vol.41 , pp. 1414-1420
    • Bachorik, P.S.1    Ross, J.W.2
  • 6
    • 0028970545 scopus 로고
    • National Cholesterol Education Program recommendations for triglyceride measurement: Executive summary
    • Stein EA, Myers GL, for the NCEP Working Group on Lipoprotein Measurement. National Cholesterol Education Program recommendations for triglyceride measurement: executive summary. Clin Chem 1995;41:1421-6.
    • (1995) Clin Chem , vol.41 , pp. 1421-1426
    • Stein, E.A.1    Myers, G.L.2
  • 7
    • 0028853551 scopus 로고
    • National Cholesterol Education Program recommendations for measurement of high-density lipoprotein cholesterol: Executive summary
    • Warnick GR, Wood PD, for the NCEP Working Group on Lipoprotein Measurement. National Cholesterol Education Program recommendations for measurement of high-density lipoprotein cholesterol: executive summary. Clin Chem 1995;41:1427-33.
    • (1995) Clin Chem , vol.41 , pp. 1427-1433
    • Warnick, G.R.1    Wood, P.D.2
  • 8
    • 0026697962 scopus 로고
    • Charts of operational process specifications ("OP-Specs charts") for assessing the precision, accuracy, and quality control needed to satisfy proficiency testing criteria
    • Westgard JO. Charts of operational process specifications ("OP-Specs charts") for assessing the precision, accuracy, and quality control needed to satisfy proficiency testing criteria. Clin Chem 1992;38:1226-33.
    • (1992) Clin Chem , vol.38 , pp. 1226-1233
    • Westgard, J.O.1
  • 9
    • 0031022102 scopus 로고    scopus 로고
    • Automated selection of statistical quality-control procedures to assure meeting clinical or analytical quality requirements [Tech Brief]
    • Westgard JO, Stein B. Automated selection of statistical quality-control procedures to assure meeting clinical or analytical quality requirements [Tech Brief]. Clin Chem 1997;43:400-3.
    • (1997) Clin Chem , vol.43 , pp. 400-403
    • Westgard, J.O.1    Stein, B.2
  • 10
    • 0030319377 scopus 로고    scopus 로고
    • Error budgets for quality management: Practical tools for planning and assuring the analytical quality of laboratory testing processes
    • Westgard JO. Error budgets for quality management: practical tools for planning and assuring the analytical quality of laboratory testing processes. Clin Lab Manage Rev 1996;10:377-403.
    • (1996) Clin Lab Manage Rev , vol.10 , pp. 377-403
    • Westgard, J.O.1
  • 12
    • 0028306843 scopus 로고
    • European specifications for imprecision and inaccuracy compared with operating specifications that assure the quality required by US CLIA proficiency-testing criteria
    • Westgard JO, Seehafer JJ, Barry PL. European specifications for imprecision and inaccuracy compared with operating specifications that assure the quality required by US CLIA proficiency-testing criteria. Clin Chem 1994;40:1228-32.
    • (1994) Clin Chem , vol.40 , pp. 1228-1232
    • Westgard, J.O.1    Seehafer, J.J.2    Barry, P.L.3
  • 13
    • 0025013905 scopus 로고
    • Precision requirements for cost-effective operation of analytical processes
    • Westgard JO, Burnett RW. Precision requirements for cost-effective operation of analytical processes. Clin Chem 1990;35:1629-32.
    • (1990) Clin Chem , vol.35 , pp. 1629-1632
    • Westgard, J.O.1    Burnett, R.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.