-
1
-
-
0028339167
-
Sources of intensity nonuniformity in spin echo images at 1.5 T
-
1. Simmons, A.; Tofts, P.S.; Barker, G.J.; Arridge, S.R. Sources of intensity nonuniformity in spin echo images at 1.5 T. Magn. Reson. Med. 32:121-128; 1994.
-
(1994)
Magn. Reson. Med.
, vol.32
, pp. 121-128
-
-
Simmons, A.1
Tofts, P.S.2
Barker, G.J.3
Arridge, S.R.4
-
2
-
-
0028903345
-
MRI segmentation: Methods and applications
-
2. Clarke, L.P.; Velthuizen, R.P.; Camacho, M.A.; Heine, J.J.; Vaidyanathan, M.L.; Hill, O.; Thatcher, R.W.; Silbiger, M.L. MRI segmentation: Methods and applications. Magn. Reson. Imaging 13:343-368; 1995.
-
(1995)
Magn. Reson. Imaging
, vol.13
, pp. 343-368
-
-
Clarke, L.P.1
Velthuizen, R.P.2
Camacho, M.A.3
Heine, J.J.4
Vaidyanathan, M.L.5
Hill, O.6
Thatcher, R.W.7
Silbiger, M.L.8
-
3
-
-
0028839871
-
The Rician distribution of noisy MRI data
-
3. Gudbjartsson, H.; Patz, S. The Rician distribution of noisy MRI data. Magn. Reson. Med. 34:910-914; 1995.
-
(1995)
Magn. Reson. Med.
, vol.34
, pp. 910-914
-
-
Gudbjartsson, H.1
Patz, S.2
-
4
-
-
0023064533
-
Image nonuniformity in magnetic resonance imaging: Its magnitude and methods for its correction
-
4. Condon, B.R.; Patterson, J.; Wyper, D.; Jenkins, A.; Hadley, D.M. Image nonuniformity in magnetic resonance imaging: Its magnitude and methods for its correction. Br. J. Radiol. 60:83-87; 1987.
-
(1987)
Br. J. Radiol.
, vol.60
, pp. 83-87
-
-
Condon, B.R.1
Patterson, J.2
Wyper, D.3
Jenkins, A.4
Hadley, D.M.5
-
5
-
-
0022995961
-
Phase and sensitivity of receiver coils in magnetic resonance medical imaging
-
5. Veigh, E.R.; Bronskill, M.J.; Henkelman, R.M. Phase and sensitivity of receiver coils in magnetic resonance medical imaging. Med. Phys. 13(6):806-814; 1986.
-
(1986)
Med. Phys.
, vol.13
, Issue.6
, pp. 806-814
-
-
Veigh, E.R.1
Bronskill, M.J.2
Henkelman, R.M.3
-
6
-
-
0027193859
-
Correction of intensity nonuniformity in MR images of any orientation
-
6. Wicks, D.A.G.; Barker, G.J.; Tofts, P.S. Correction of intensity nonuniformity in MR images of any orientation. Magn. Reson. Imaging 11:183-196; 1993.
-
(1993)
Magn. Reson. Imaging
, vol.11
, pp. 183-196
-
-
Wicks, D.A.G.1
Barker, G.J.2
Tofts, P.S.3
-
7
-
-
0023913522
-
Correction for the intensity falloff in surface coil magnetic resonance imaging
-
7. Brey, W.W.; Narayana, P.A. Correction for the intensity falloff in surface coil magnetic resonance imaging. Med. Phys. 15(2):241-245; 1988.
-
(1988)
Med. Phys.
, vol.15
, Issue.2
, pp. 241-245
-
-
Brey, W.W.1
Narayana, P.A.2
-
8
-
-
0023940563
-
Compensation for surface coil sensitivity variation in magnetic resonance imaging
-
8. Narayana, P.A.; Brey, W.W.; Kulkarni, M.V.; Sievenpiper, C.L. Compensation for surface coil sensitivity variation in magnetic resonance imaging. Magn. Reson. Imaging 6: 271-274; 1988.
-
(1988)
Magn. Reson. Imaging
, vol.6
, pp. 271-274
-
-
Narayana, P.A.1
Brey, W.W.2
Kulkarni, M.V.3
Sievenpiper, C.L.4
-
9
-
-
0025657240
-
Analysis of random noise, coil inhomogeneity, and ghost artefacts in spin-echo imaging on a 1.5 T commercial magnetic resonance imager
-
A.C. Bovick (Ed)
-
9. Chandra, R.; Rusinek, H. Analysis of random noise, coil inhomogeneity, and ghost artefacts in spin-echo imaging on a 1.5 T commercial magnetic resonance imager. In: A.C. Bovick (Ed). Biomedical Image Processing, Proceedings SPIE 1245:124-134; 1990.
-
(1990)
Biomedical Image Processing, Proceedings SPIE
, vol.1245
, pp. 124-134
-
-
Chandra, R.1
Rusinek, H.2
-
10
-
-
0022863971
-
An algorithm for the compensation of surface-coil images for the sensitivity of the surface coil
-
10. Haselgrove, J.; Prammer, M. An algorithm for the compensation of surface-coil images for the sensitivity of the surface coil. Magn. Reson. Imaging 4:469-472; 1986.
-
(1986)
Magn. Reson. Imaging
, vol.4
, pp. 469-472
-
-
Haselgrove, J.1
Prammer, M.2
-
11
-
-
0027850154
-
Correction of intensity variations in MR images for computer-aided tissue classification
-
11. Dawant, B.M.; Zijdenbos, A.P.; Margolin, R.A. Correction of intensity variations in MR images for computer-aided tissue classification. IEEE Transact. Med. Imaging 12(4): 770-781; 1993.
-
(1993)
IEEE Transact. Med. Imaging
, vol.12
, Issue.4
, pp. 770-781
-
-
Dawant, B.M.1
Zijdenbos, A.P.2
Margolin, R.A.3
-
12
-
-
0027607954
-
Polynomial modelling and reduction of RF body coil spatial inhomogeneity in MRI
-
12. Tincher, M.; Meyer, C.R.; Gupta, R.; Williams, D.M. Polynomial modelling and reduction of RF body coil spatial inhomogeneity in MRI. IEEE Trans. Med. Imaging 12(2):361-366; 1993.
-
(1993)
IEEE Trans. Med. Imaging
, vol.12
, Issue.2
, pp. 361-366
-
-
Tincher, M.1
Meyer, C.R.2
Gupta, R.3
Williams, D.M.4
-
13
-
-
85076726161
-
Statistical intensity correction and segmentation of magnetic resonance image data
-
13. Wells, W.; Kikins, R.; Grimson, F.; Jolesz, F.A. Statistical intensity correction and segmentation of magnetic resonance image data. In: Visualisation in Biomedical Computing 1994, Proceedings of SPIE 2359:13-24; 1994.
-
(1994)
Visualisation in Biomedical Computing 1994, Proceedings of SPIE
, vol.2359
, pp. 13-24
-
-
Wells, W.1
Kikins, R.2
Grimson, F.3
Jolesz, F.A.4
-
14
-
-
0025890385
-
Observations on maximum entropy processing of MR images
-
14. Moran, P.R. Observations on maximum entropy processing of MR images. Magn. Reson. Imaging 9:213-221; 1991.
-
(1991)
Magn. Reson. Imaging
, vol.9
, pp. 213-221
-
-
Moran, P.R.1
|