메뉴 건너뛰기




Volumn 81, Issue 12, 1997, Pages 1050-1055

Pulfrich's phenomenon in unilateral cataract

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CATARACT; CATARACT EXTRACTION; CLINICAL ARTICLE; COMPUTER ANALYSIS; CONTROLLED STUDY; HANGING; HUMAN; LENS IMPLANT; PRIORITY JOURNAL; PSEUDOPHAKIA; PULFRICH EFFECT; VISUAL ACUITY; VISUAL ILLUSION;

EID: 0030657047     PISSN: 00071161     EISSN: None     Source Type: Journal    
DOI: 10.1136/bjo.81.12.1050     Document Type: Article
Times cited : (29)

References (22)
  • 1
    • 34250908167 scopus 로고
    • Die Stereoskopie im Dienste der Isochromen und Heterochromen Photomtrie
    • Pulfrich C. Die Stereoskopie im Dienste der Isochromen und Heterochromen Photomtrie. Naturwissenschaften 1922;10:533-64.
    • (1922) Naturwissenschaften , vol.10 , pp. 533-564
    • Pulfrich, C.1
  • 2
    • 0017809244 scopus 로고
    • Retinal mechanisms of visual latency
    • Mansfield RJW, Daugman JD. Retinal mechanisms of visual latency. Vision Res 1978;18:1247-60.
    • (1978) Vision Res , vol.18 , pp. 1247-1260
    • Mansfield, R.J.W.1    Daugman, J.D.2
  • 3
    • 0016735430 scopus 로고
    • Use of the Pulfrich pendulum for detecting abnormal delay in the visual pathway in multiple sclerosis
    • Rushton D. Use of the Pulfrich pendulum for detecting abnormal delay in the visual pathway in multiple sclerosis. Brain 1975;98:283-96.
    • (1975) Brain , vol.98 , pp. 283-296
    • Rushton, D.1
  • 4
    • 0014960441 scopus 로고
    • Distortions of apparent velocity: A new optical illusion
    • Enright JT. Distortions of apparent velocity: a new optical illusion. Science 1970;168:464-7.
    • (1970) Science , vol.168 , pp. 464-467
    • Enright, J.T.1
  • 5
    • 0024792398 scopus 로고
    • The Pulfrich phenomenon and its alleviation with a neutral density filter
    • Heron G, Dutton GN. The Pulfrich phenomenon and its alleviation with a neutral density filter. Br J Ophthalmol 1989;73:1004-8.
    • (1989) Br J Ophthalmol , vol.73 , pp. 1004-1008
    • Heron, G.1    Dutton, G.N.2
  • 6
    • 0027444779 scopus 로고
    • Can second eye cataract extraction be justified?
    • Laidlaw A, Harrad R. Can second eye cataract extraction be justified? Eye 1993;7:680-6.
    • (1993) Eye , vol.7 , pp. 680-686
    • Laidlaw, A.1    Harrad, R.2
  • 8
    • 0001255163 scopus 로고
    • Binocular rivalry in patients with unilateral cataract: A previously unrecognised cause of visual disability
    • Harrad RA, Whitaker A, Laidlaw DAH. Binocular rivalry in patients with unilateral cataract: A previously unrecognised cause of visual disability. Invest Ophthalmol Vis Sci 1994;35:1964.
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , pp. 1964
    • Harrad, R.A.1    Whitaker, A.2    Laidlaw, D.A.H.3
  • 9
    • 0020418336 scopus 로고
    • Improvements in the accuracy of pattern visual evoked potentials in the diagnosis of visual pathway disease
    • Carroll WM, Halliday AM, Kriss A. Improvements in the accuracy of pattern visual evoked potentials in the diagnosis of visual pathway disease. Neuro-ophthalmology 1982;2: 237-53.
    • (1982) Neuro-ophthalmology , vol.2 , pp. 237-253
    • Carroll, W.M.1    Halliday, A.M.2    Kriss, A.3
  • 10
    • 0018403814 scopus 로고
    • Effect of refractive error on the visual evoked response
    • Collins DWK, Carroll WM, Black JL, Walsh M. Effect of refractive error on the visual evoked response. BMJ 1979; 1:231-2.
    • (1979) BMJ , vol.1 , pp. 231-232
    • Collins, D.W.K.1    Carroll, W.M.2    Black, J.L.3    Walsh, M.4
  • 13
    • 0019504741 scopus 로고
    • Effect of retinal blur on the peak latency of the pattern evoked potential
    • Sokol S, Moskowitz A. Effect of retinal blur on the peak latency of the pattern evoked potential. Vis Res 1981;21: 1279-86.
    • (1981) Vis Res , vol.21 , pp. 1279-1286
    • Sokol, S.1    Moskowitz, A.2
  • 14
    • 0025689257 scopus 로고
    • Transmission of light through cataracts
    • Sadun AA, Libondi T. Transmission of light through cataracts. Am J Ophthalmol 1990;110:710-2.
    • (1990) Am J Ophthalmol , vol.110 , pp. 710-712
    • Sadun, A.A.1    Libondi, T.2
  • 15
  • 16
    • 0025679066 scopus 로고
    • Why cataracts do not produce afferent pupillary defects
    • Sadun AA, Bassi CJ, Lessell S. Why cataracts do not produce afferent pupillary defects. Am J Ophthalmol 1990; 110:712-4.
    • (1990) Am J Ophthalmol , vol.110 , pp. 712-714
    • Sadun, A.A.1    Bassi, C.J.2    Lessell, S.3
  • 18
    • 84953172098 scopus 로고
    • Measurements of the Pulfrich effect over days of exposure
    • Landrigan DT. Measurements of the Pulfrich effect over days of exposure. J Psychol 1984;117:125-33.
    • (1984) J Psychol , vol.117 , pp. 125-133
    • Landrigan, D.T.1
  • 19
    • 0025760958 scopus 로고
    • The importance of measuring binocular contrast sensitivity in unilateral cataracts
    • Pardhan S, Gilchrist J. The importance of measuring binocular contrast sensitivity in unilateral cataracts. Eye 1991;5:31-5.
    • (1991) Eye , vol.5 , pp. 31-35
    • Pardhan, S.1    Gilchrist, J.2
  • 20
    • 0040967871 scopus 로고
    • A note on the Pulfrich phenomenon with a suggestion on the possible clinical importance
    • Grimsdale H. A note on the Pulfrich phenomenon with a suggestion on the possible clinical importance. Br J Ophthalmol 1925;9:63-5.
    • (1925) Br J Ophthalmol , vol.9 , pp. 63-65
    • Grimsdale, H.1
  • 21
  • 22
    • 0028036985 scopus 로고
    • Impaired perception of moving objects after minor injuries to the eye and midface: The Pulfrich phenomenon
    • Larkin EB, Dutton GN, Heron G. Impaired perception of moving objects after minor injuries to the eye and midface: the Pulfrich phenomenon. Br J Oral Maxillofacial Surg 1994;32:360-2.
    • (1994) Br J Oral Maxillofacial Surg , vol.32 , pp. 360-362
    • Larkin, E.B.1    Dutton, G.N.2    Heron, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.