메뉴 건너뛰기




Volumn 29, Issue 1, 1997, Pages 18-25

Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution

Author keywords

Cardiac output; Doppler; Echocardiography; Horse; Thermodilution

Indexed keywords

EQUIDAE; EQUUS CABALLUS;

EID: 0030641393     PISSN: 04251644     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.2042-3306.1997.tb01631.x     Document Type: Article
Times cited : (43)

References (43)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J.M. and Altman, D.G. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 1, 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 0029362013 scopus 로고
    • Pulsed wave Doppler echocardiography in normal horses
    • Blissitt, K.J. and Bonagura, J.D. (1995) Pulsed wave Doppler echocardiography in normal horses. Equine vet. J., Suppl. 19, 38-47
    • (1995) Equine Vet. J., Suppl. , vol.19 , pp. 38-47
    • Blissitt, K.J.1    Bonagura, J.D.2
  • 5
    • 0017650703 scopus 로고
    • Estimation of stroke volume changes by ultrasonic Doppler
    • Colocousis, J.S., Huntsman, L.L. and Curreri, P.W. (1977) Estimation of stroke volume changes by ultrasonic Doppler Circulation, 56, 914-917
    • (1977) Circulation , vol.56 , pp. 914-917
    • Colocousis, J.S.1    Huntsman, L.L.2    Curreri, P.W.3
  • 6
    • 0025291657 scopus 로고
    • Comparative accuracy of Doppler echocardiographic methods for clinical stroke volume determination
    • Dubin, J., Wallerson, D.C., Cody, R.J. and Devereux, R.B. (1990) Comparative accuracy of Doppler echocardiographic methods for clinical stroke volume determination. Am. Heart J 120, 116-123
    • (1990) Am. Heart J , vol.120 , pp. 116-123
    • Dubin, J.1    Wallerson, D.C.2    Cody, R.J.3    Devereux, R.B.4
  • 7
    • 0021076099 scopus 로고
    • Cardiac output by thermodilution technique. Effect of injectates volume and temperature on accuracy and reproducibility in the critically ill patient
    • Elkayam, U., Berkley, R., Azen, S., Weber, L., Geva, B. and Henry, W.L. (1983) Cardiac output by thermodilution technique. Effect of injectates volume and temperature on accuracy and reproducibility in the critically ill patient. Chest 84, 418-422.
    • (1983) Chest , vol.84 , pp. 418-422
    • Elkayam, U.1    Berkley, R.2    Azen, S.3    Weber, L.4    Geva, B.5    Henry, W.L.6
  • 8
    • 0025242457 scopus 로고
    • Improved method for cardiac output determination in man using ultrasound Doppler technique
    • Eriksen, M. and Walloe, L. (1990) Improved method for cardiac output determination in man using ultrasound Doppler technique. Med Biol. Eng. Comp 28, 555-560.
    • (1990) Med Biol. Eng. Comp , vol.28 , pp. 555-560
    • Eriksen, M.1    Walloe, L.2
  • 9
    • 0011870452 scopus 로고
    • Cardiac output measured by thermal dilution of room temperature injectate
    • Evonuk, E., Irnig, C.J., Greenfield, W. and Eckstein, J.W. (1960) Cardiac output measured by thermal dilution of room temperature injectate. J. appl Physiol 16, 271-275
    • (1960) J. Appl Physiol , vol.16 , pp. 271-275
    • Evonuk, E.1    Irnig, C.J.2    Greenfield, W.3    Eckstein, J.W.4
  • 10
    • 2542448645 scopus 로고
    • Ed. E. Braunwald W.B. Saunders, Philadelphia
    • Feigenbaum, H. (1988) Heart disease, 3rd edn Ed. E. Braunwald W.B. Saunders, Philadelphia, pp 83-139.
    • (1988) Heart Disease, 3rd Edn , pp. 83-139
    • Feigenbaum, H.1
  • 12
    • 0343537970 scopus 로고
    • Cardiac output in horses
    • Fisher, E.W. and Dalton, R.G. (1959) Cardiac output in horses. Nature 184, 2020-2021.
    • (1959) Nature , vol.184 , pp. 2020-2021
    • Fisher, E.W.1    Dalton, R.G.2
  • 13
    • 2542452372 scopus 로고
    • Determination of the cardiac output of cattle and horses by the injection method
    • Fisher, E.W. and Dalton, R.G. (1961) Determination of the cardiac output of cattle and horses by the injection method. Br. vet. J. 118, 143-151.
    • (1961) Br. Vet. J. , vol.118 , pp. 143-151
    • Fisher, E.W.1    Dalton, R.G.2
  • 14
    • 0015041424 scopus 로고
    • A new technique for measurement of cardiac output by thermodilution in man
    • Ganz, W., Donoso, R., Marcus, H.S., Forrester, J.S. and Swan, H.J.C. (1971) A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol. 27, 392-396.
    • (1971) Am J Cardiol. , vol.27 , pp. 392-396
    • Ganz, W.1    Donoso, R.2    Marcus, H.S.3    Forrester, J.S.4    Swan, H.J.C.5
  • 16
    • 0021845202 scopus 로고
    • Assessment of cardiac output by the Doppler ultrasound technique alone
    • Haites, N.B., McLennan, F.M., Mowat, D.H.R. and Rawles, J.M. (1985) Assessment of cardiac output by the Doppler ultrasound technique alone Br. Heart J 53, 123-129.
    • (1985) Br. Heart J , vol.53 , pp. 123-129
    • Haites, N.B.1    McLennan, F.M.2    Mowat, D.H.R.3    Rawles, J.M.4
  • 17
    • 0016419121 scopus 로고
    • Cardiac output in the conscious and anaesthetised horse
    • Hillidge, C.J. and Lees, P. (1985) Cardiac output in the conscious and anaesthetised horse. Equine vet J. 7, 16-20.
    • (1985) Equine Vet J. , vol.7 , pp. 16-20
    • Hillidge, C.J.1    Lees, P.2
  • 19
    • 84983978248 scopus 로고
    • Accuracy of the thermodilution method in estimating high flow - An in vitro study
    • Jarvis, K.A., Woliner, M.J. and Steffey, E.P. (1992) Accuracy of the thermodilution method in estimating high flow - an in vitro study. J. vet Anaesth. 19, 41-45
    • (1992) J. Vet Anaesth. , vol.19 , pp. 41-45
    • Jarvis, K.A.1    Woliner, M.J.2    Steffey, E.P.3
  • 20
    • 0022627051 scopus 로고
    • Pulsatile flow simulator for comparison of cardiac output measurements by electromagnetic flow meter and thermodilution
    • Jebson, P.J.R. and Karkow, W.S. (1986) Pulsatile flow simulator for comparison of cardiac output measurements by electromagnetic flow meter and thermodilution. J. clin. Monit 2, 6-14.
    • (1986) J. Clin. Monit , vol.2 , pp. 6-14
    • Jebson, P.J.R.1    Karkow, W.S.2
  • 21
    • 0014568024 scopus 로고
    • Transcutaneous observation of blood velocity in the ascending aorta in man. the Proceedings of the Physiological Society
    • Light, L.H. (1969) Transcutaneous observation of blood velocity in the ascending aorta in man. The Proceedings of the Physiological Society. J. Physiol. 204, 1P-2P.
    • (1969) J. Physiol. , vol.204
    • Light, L.H.1
  • 22
    • 0018639392 scopus 로고
    • Thermodilution cardiac output: A critical analysis and review of the literature
    • Levett, J.M. and Replogle, R.L. (1979) Thermodilution cardiac output: A critical analysis and review of the literature. J. surg. Res. 27, 392-404.
    • (1979) J. Surg. Res. , vol.27 , pp. 392-404
    • Levett, J.M.1    Replogle, R.L.2
  • 23
    • 0021211548 scopus 로고
    • Doppler echocardiographic comparison of flows distal to the four cardiac valves
    • Loeber, C.P., Goldberg, S.J. and Allen, H.D. (1984) Doppler echocardiographic comparison of flows distal to the four cardiac valves J. Am Coll Cardiol 4, 268-272
    • (1984) J. Am Coll Cardiol , vol.4 , pp. 268-272
    • Loeber, C.P.1    Goldberg, S.J.2    Allen, H.D.3
  • 24
    • 0026862871 scopus 로고
    • Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse
    • Long, K.J., Bonagura, J.D. and Darke, P.G.G. (1992) Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse. Equine vet. J. 24, 226-235.
    • (1992) Equine Vet. J. , vol.24 , pp. 226-235
    • Long, K.J.1    Bonagura, J.D.2    Darke, P.G.G.3
  • 25
    • 0022590888 scopus 로고
    • Method of assessing the reproducability of blood flow measurement: Factors influencing the performance of thermodilution cardiac output computers
    • Mackenzie, J.D., Haites, N.E. and Rawles, J.M. (1986) Method of assessing the reproducability of blood flow measurement: Factors influencing the performance of thermodilution cardiac output computers Br Heart J. 55, 14-24.
    • (1986) Br Heart J. , vol.55 , pp. 14-24
    • Mackenzie, J.D.1    Haites, N.E.2    Rawles, J.M.3
  • 26
    • 0022476656 scopus 로고
    • Impaired left ventricular function in acute myocardial infarction assessed by Doppler measurement of ascending aortic blood velocity and maximum acceleration
    • Mehta, N. and Bennett, D.E. (1986) Impaired left ventricular function in acute myocardial infarction assessed by Doppler measurement of ascending aortic blood velocity and maximum acceleration Am J. Cardiol. 57, 1052-1058.
    • (1986) Am J. Cardiol. , vol.57 , pp. 1052-1058
    • Mehta, N.1    Bennett, D.E.2
  • 28
    • 0028372763 scopus 로고
    • Comparison of methods of cardiac output measurements determined by dye dilution, pulsed Doppler echocardiography and thermodilution in horses
    • Mizuno, Y., Aida, H., Hara, H., Fujinaga, T. and Hagio, M. (1994) Comparison of methods of cardiac output measurements determined by dye dilution, pulsed Doppler echocardiography and thermodilution in horses J. vet med Sci. 56, 1-5.
    • (1994) J. Vet Med Sci. , vol.56 , pp. 1-5
    • Mizuno, Y.1    Aida, H.2    Hara, H.3    Fujinaga, T.4    Hagio, M.5
  • 29
    • 0016970822 scopus 로고
    • Estimation of cardiac output in the horse by thermodilution techniques
    • Muir, W.W., Skarda, R.T. and Milne, D.W (1976) Estimation of cardiac output in the horse by thermodilution techniques. Am. J. vet. Res 37, 697-700.
    • (1976) Am. J. Vet. Res , vol.37 , pp. 697-700
    • Muir, W.W.1    Skarda, R.T.2    Milne, D.W.3
  • 30
    • 0023029836 scopus 로고
    • Limitations of cardiac output measurements by thermodilution
    • Nadeau, S. and Noble, W.H. (1986) Limitations of cardiac output measurements by thermodilution. Can. Anaest. Soc. J. 33, 780-784.
    • (1986) Can. Anaest. Soc. J. , vol.33 , pp. 780-784
    • Nadeau, S.1    Noble, W.H.2
  • 31
    • 0025124559 scopus 로고
    • Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance
    • Northridge, D.D., Findlay, I.N., Wilson, J. Henderson, E. and Dargie, H.J. (1990) Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance. Br Heart J 63, 93-97.
    • (1990) Br Heart J , vol.63 , pp. 93-97
    • Northridge, D.D.1    Findlay, I.N.2    Wilson, J.3    Henderson, E.4    Dargie, H.J.5
  • 32
    • 0017939444 scopus 로고
    • In vitro comparison of six commercially available thermodilution cardiac output systems
    • Powner, D.J. and Snyder, J.V. (1978) In vitro comparison of six commercially available thermodilution cardiac output systems. Med. Instr 12, 122-127.
    • (1978) Med. Instr , vol.12 , pp. 122-127
    • Powner, D.J.1    Snyder, J.V.2
  • 33
    • 0025305774 scopus 로고
    • Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: Comparisons with dye dilution and thermodilution
    • Russell, A.E., Smith, S.A., West, M.J., Aylward, P.E., McRitchie, R.J., Hassam, R.M., Minson, R.B., Wing, L.M.H. and Chalmers, J.P. (1990) Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution. Br Heart J. 63, 195-199
    • (1990) Br Heart J. , vol.63 , pp. 195-199
    • Russell, A.E.1    Smith, S.A.2    West, M.J.3    Aylward, P.E.4    McRitchie, R.J.5    Hassam, R.M.6    Minson, R.B.7    Wing, L.M.H.8    Chalmers, J.P.9
  • 35
    • 0021314242 scopus 로고
    • Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standard
    • Schuster, A.H. and Nanda, N.C. (1984) Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standard Am. J. Cardiol 53, 257-259.
    • (1984) Am. J. Cardiol , vol.53 , pp. 257-259
    • Schuster, A.H.1    Nanda, N.C.2
  • 36
    • 0017198356 scopus 로고
    • Transcutaneous aortovelography. A quantitative evaluation
    • Sequeira, R.F., Light, H.L., Cross, G. and Raftery, E.B. (1976) Transcutaneous aortovelography. A quantitative evaluation Br Heart J. 38, 443-450
    • (1976) Br Heart J. , vol.38 , pp. 443-450
    • Sequeira, R.F.1    Light, H.L.2    Cross, G.3    Raftery, E.B.4
  • 37
    • 0020527770 scopus 로고
    • Reproducability and accuracy of using room-temperature vs ice-temperature injectate for thermodilution cardiac output determination
    • Shellock, F.G. and Riedinger, M.S. (1983) Reproducability and accuracy of using room-temperature vs ice-temperature injectate for thermodilution cardiac output determination. Heart Lung, 12, 175-176
    • (1983) Heart Lung , vol.12 , pp. 175-176
    • Shellock, F.G.1    Riedinger, M.S.2
  • 38
    • 0028488027 scopus 로고
    • Evaluation of systolic heart function of the horse with PW Doppler echocardiography compared with thermodilution
    • Stadler, P., Kinkel, N. and Deegen, E. (1994) Evaluation of systolic heart function of the horse with PW Doppler echocardiography compared with thermodilution. Deutsche Tierarz Wochenschrift, 101, 312-315
    • (1994) Deutsche Tierarz Wochenschrift , vol.101 , pp. 312-315
    • Stadler, P.1    Kinkel, N.2    Deegen, E.3
  • 39
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz, C.W., Millar, R.G., Kelly, G.E. and Raffin, T.A. (1982) Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev. resp. Dis. 126, 1001-1004.
    • (1982) Am Rev. Resp. Dis. , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Millar, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 40
    • 84939082594 scopus 로고
    • Researches on the circulation time and on the influences which affect it. IV. the output of the heart
    • Stewart, G.N. (1897) Researches on the circulation time and on the influences which affect it. IV. The output of the heart J Physiol 22, 159-183.
    • (1897) J Physiol , vol.22 , pp. 159-183
    • Stewart, G.N.1
  • 42
    • 85033158583 scopus 로고
    • Doctorate Thesis. University of Hannover, Germany
    • Weinberger, T. (1991) Doctorate Thesis. University of Hannover, Germany
    • (1991)
    • Weinberger, T.1
  • 43
    • 0022361983 scopus 로고
    • Major errors in thermodilution cardiac output measurement during rapid volume infusion
    • Wetzel, R.C. and Latson, T.W. (1985) Major errors in thermodilution cardiac output measurement during rapid volume infusion. Anaesthesiology, 62, 684-687
    • (1985) Anaesthesiology , vol.62 , pp. 684-687
    • Wetzel, R.C.1    Latson, T.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.