-
1
-
-
0028955646
-
Differentiation between dysmyelination and demyelination using magnetic resonance diffusional anisotropy
-
Ono J, Harada K, Takahashi M, et al: Differentiation between dysmyelination and demyelination using magnetic resonance diffusional anisotropy. Brain Res 671: 141-148, 1995
-
(1995)
Brain Res
, vol.671
, pp. 141-148
-
-
Ono, J.1
Harada, K.2
Takahashi, M.3
-
2
-
-
0025046502
-
Diffusion-weighted MR imaging of the brain: Value of differentiating between extraaxial cysts and epidermoid tumors
-
Tsuruda JS, Chew WM, Moseley ME, et al: Diffusion-weighted MR imaging of the brain: value of differentiating between extraaxial cysts and epidermoid tumors. AJNR 11: 925-931, 1990
-
(1990)
AJNR
, vol.11
, pp. 925-931
-
-
Tsuruda, J.S.1
Chew, W.M.2
Moseley, M.E.3
-
3
-
-
0022969218
-
MR imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders
-
Le Bihan D, Breton E, Lallemand D, et al: MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161: 401-407, 1986
-
(1986)
Radiology
, vol.161
, pp. 401-407
-
-
Le Bihan, D.1
Breton, E.2
Lallemand, D.3
-
4
-
-
0023678634
-
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging
-
Le Bihan D, Breton E, Lallemand D, et al: Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168: 497-505, 1988
-
(1988)
Radiology
, vol.168
, pp. 497-505
-
-
Le Bihan, D.1
Breton, E.2
Lallemand, D.3
-
5
-
-
0025115647
-
Anisotropic diffusion in human white matter: Demonstration with MR techniques in vivo
-
Chenevert TL, Brunberg JA, Pipe JG: Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo. Radiology 177: 401-405, 1990
-
(1990)
Radiology
, vol.177
, pp. 401-405
-
-
Chenevert, T.L.1
Brunberg, J.A.2
Pipe, J.G.3
-
6
-
-
0025323825
-
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system
-
Moseley ME, Cohen Y, Kucharczyk J, et al: Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system. Radiology 176: 439-445, 1990
-
(1990)
Radiology
, vol.176
, pp. 439-445
-
-
Moseley, M.E.1
Cohen, Y.2
Kucharczyk, J.3
-
7
-
-
0025807174
-
Adult and neonatal human brain: Diffusional anisotropy and myelination with diffusion-weighted MR imaging
-
Sakuma H, Nomura Y, Takeda K, et al: Adult and neonatal human brain: diffusional anisotropy and myelination with diffusion-weighted MR imaging. Radiology 180: 229-233, 1991
-
(1991)
Radiology
, vol.180
, pp. 229-233
-
-
Sakuma, H.1
Nomura, Y.2
Takeda, K.3
-
8
-
-
0028118461
-
Abdominal diffusion mapping with use of a whole-body echo-planar system
-
Muller MF, Prasad P, Siewert B, et al: Abdominal diffusion mapping with use of a whole-body echo-planar system. Radiology 190: 475-478, 1994
-
(1994)
Radiology
, vol.190
, pp. 475-478
-
-
Muller, M.F.1
Prasad, P.2
Siewert, B.3
-
9
-
-
0028090623
-
Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient
-
Muller MF, Prasad PV, Bimmler D, et al: Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. Radiology 193: 711-715, 1994
-
(1994)
Radiology
, vol.193
, pp. 711-715
-
-
Muller, M.F.1
Prasad, P.V.2
Bimmler, D.3
-
10
-
-
0025773955
-
Magnetic resonance diffusion/perfusion phantom experiments
-
Lorenz CH, Pickens DRd, Puffer DB, et al: Magnetic resonance diffusion/perfusion phantom experiments. Magn Reson Med 19: 254-260, 1991
-
(1991)
Magn Reson Med
, vol.19
, pp. 254-260
-
-
Lorenz, C.H.1
Pickens, D.Rd.2
Puffer, D.B.3
-
11
-
-
0022001875
-
Volumetric NMR imaging with time-varying gradients
-
Macovski A: Volumetric NMR imaging with time-varying gradients. Magn Reson Med 2: 29-40, 1985
-
(1985)
Magn Reson Med
, vol.2
, pp. 29-40
-
-
Macovski, A.1
-
12
-
-
0028935442
-
A perspective on K-space
-
Mezrich R: A perspective on K-space. Radiology 195: 297-315, 1995
-
(1995)
Radiology
, vol.195
, pp. 297-315
-
-
Mezrich, R.1
-
15
-
-
2542470879
-
-
Japanese source
-
-
-
-
16
-
-
0026587273
-
Magnetic resonance perfusion/diffusion imaging of the excised dog kidney
-
Pickens DRd, Jolgren DL, Lorenz CH, et al: Magnetic resonance perfusion/diffusion imaging of the excised dog kidney. Invest Radiol 27:287-292, 1992
-
(1992)
Invest Radiol
, vol.27
, pp. 287-292
-
-
Pickens, D.Rd.1
Jolgren, D.L.2
Lorenz, C.H.3
-
17
-
-
0025961862
-
Renal artery stenosis: In vivo perfusion MR imaging
-
Powers TA, Lorenz CH, Holburn GE, et al: Renal artery stenosis: in vivo perfusion MR imaging. Radiology 178: 543-548, 1991
-
(1991)
Radiology
, vol.178
, pp. 543-548
-
-
Powers, T.A.1
Lorenz, C.H.2
Holburn, G.E.3
|