메뉴 건너뛰기




Volumn 4, Issue 1, 1997, Pages 1-7

Mixture Distribution and Receiver Operating Characteristic Analysis of Bedside Chest Imaging with Screen-Film and Computed Radiography

Author keywords

Bedside chest radiography; Computed radiography; Mixture distribution analysis; Receiver operating characteristic analysis; Technology evaluation

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; HOSPITAL INFORMATION SYSTEM; HUMAN; INTENSIVE CARE UNIT; METHODOLOGY; ROC CURVE; SINGLE BLIND PROCEDURE; THORAX RADIOGRAPHY;

EID: 0030639630     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1076-6332(97)80152-3     Document Type: Article
Times cited : (16)

References (19)
  • 2
    • 0024511244 scopus 로고
    • Some practical issues of experimental design and data analysis in radiographic ROC studies
    • Metz CE. Some practical issues of experimental design and data analysis in radiographic ROC studies. Invest Radiol 1989;24:235-245.
    • (1989) Invest Radiol , vol.24 , pp. 235-245
    • Metz, C.E.1
  • 3
    • 0022501491 scopus 로고
    • The influence of uninterpretability on the assessment of diagnostic tests
    • Begg CB, Greenes RA, Iglewicz B. The influence of uninterpretability on the assessment of diagnostic tests. J Chron Dis 1986;39:575-584.
    • (1986) J Chron Dis , vol.39 , pp. 575-584
    • Begg, C.B.1    Greenes, R.A.2    Iglewicz, B.3
  • 4
    • 0020569380 scopus 로고
    • The effect of verification on the assessment of imaging techniques
    • Revesz G, Kundel HL, Bonitatibus M. The effect of verification on the assessment of imaging techniques. Invest Radiol 1982;18:194-198.
    • (1982) Invest Radiol , vol.18 , pp. 194-198
    • Revesz, G.1    Kundel, H.L.2    Bonitatibus, M.3
  • 6
    • 21144474819 scopus 로고
    • Statistical modeling of expert ratings on medical treatment appropriateness
    • Uebersax JS. Statistical modeling of expert ratings on medical treatment appropriateness. J Am Stat Assn 1993;88:421-427.
    • (1993) J Am Stat Assn , vol.88 , pp. 421-427
    • Uebersax, J.S.1
  • 7
    • 0024368898 scopus 로고
    • Using latent class models to characterize and assess relative error in discrete measurements
    • Espeland MA, Handelman SL. Using latent class models to characterize and assess relative error in discrete measurements. Biometrics 1989;45:587-599.
    • (1989) Biometrics , vol.45 , pp. 587-599
    • Espeland, M.A.1    Handelman, S.L.2
  • 8
    • 0027278563 scopus 로고
    • Quasi-symmetric latent class models with applications to rater agreement
    • Agresti A, Lang JB. Quasi-symmetric latent class models with applications to rater agreement. Biometrics 1993;49:131-139.
    • (1993) Biometrics , vol.49 , pp. 131-139
    • Agresti, A.1    Lang, J.B.2
  • 9
    • 0346244145 scopus 로고
    • Accuracy and agreement of readings on portable chest radiographs made in a medical intensive care unit: A comparison of conventional film and digital radiography
    • Lemke H, Inamura K, Jaffee C, Vannier M, eds. Berlin, Germany: Springer Verlag
    • Kundel H, Wells D, Gefter W, Aronchik J, Miller WS, Miller WJ. Accuracy and agreement of readings on portable chest radiographs made in a medical intensive care unit: a comparison of conventional film and digital radiography. In: Lemke H, Inamura K, Jaffee C, Vannier M, eds. Computer-assisted radiology. Berlin, Germany: Springer Verlag, 1995;89-94.
    • (1995) Computer-assisted Radiology , pp. 89-94
    • Kundel, H.1    Wells, D.2    Gefter, W.3    Aronchik, J.4    Miller, W.S.5    Miller, W.J.6
  • 10
    • 13344285353 scopus 로고    scopus 로고
    • A prospective study of a PACS: Information flow and clinical action in a medical intensive care unit
    • Kundel HL, Seshadri SB, Langlotz CP, et al. A prospective study of a PACS: information flow and clinical action in a medical intensive care unit. Radiology 1996;199:143-149.
    • (1996) Radiology , vol.199 , pp. 143-149
    • Kundel, H.L.1    Seshadri, S.B.2    Langlotz, C.P.3
  • 11
    • 0002629270 scopus 로고
    • Maximum likelihood from incomplete data via the EM algorithm
    • Dempster A, Laird N, Rubin D. Maximum likelihood from incomplete data via the EM algorithm. J Royal Stat Soc 1977;B39:1-38.
    • (1977) J Royal Stat Soc , vol.B39 , pp. 1-38
    • Dempster, A.1    Laird, N.2    Rubin, D.3
  • 12
    • 84923818429 scopus 로고
    • Better bootstrap confidence intervals
    • Efron B. Better bootstrap confidence intervals. J Am Stat Assn 1987; 82:171-200.
    • (1987) J Am Stat Assn , vol.82 , pp. 171-200
    • Efron, B.1
  • 13
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982;143:29-36.
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 15
    • 0025215710 scopus 로고
    • Receiver operating characteristic (ROC) analysis without truth
    • Henkelman RM, Kay I, Bronskill MJ. Receiver operating characteristic (ROC) analysis without truth. Med Decis Making 1990;10:24-29.
    • (1990) Med Decis Making , vol.10 , pp. 24-29
    • Henkelman, R.M.1    Kay, I.2    Bronskill, M.J.3
  • 16
    • 0025218705 scopus 로고
    • Consensus diagnoses and "gold standards."
    • Begg CB, Metz CE. Consensus diagnoses and "gold standards." Med Decis Making 1990;10:29-30.
    • (1990) Med Decis Making , vol.10 , pp. 29-30
    • Begg, C.B.1    Metz, C.E.2
  • 17
    • 0022370337 scopus 로고
    • Assessment of diagnostic technologies: Methodology for unbiased estimation from samples of selectively verified patients
    • Greenes RA, Begg CB. Assessment of diagnostic technologies: methodology for unbiased estimation from samples of selectively verified patients. Invest Radiol 1985;20:751-756.
    • (1985) Invest Radiol , vol.20 , pp. 751-756
    • Greenes, R.A.1    Begg, C.B.2
  • 18
    • 0025272377 scopus 로고
    • Receiver operating characteristic analysis of chest image interpretation with conventional, laser printed, and high-resolution workstation images
    • Slasky BS, Gur D, Good WF, et al. Receiver operating characteristic analysis of chest image interpretation with conventional, laser printed, and high-resolution workstation images. Radiology 1990;174:775-780.
    • (1990) Radiology , vol.174 , pp. 775-780
    • Slasky, B.S.1    Gur, D.2    Good, W.F.3
  • 19
    • 0025781618 scopus 로고
    • Photostimulable phosphor digital radiography of the extremities: Diagnostic accuracy compared with conventional radiography
    • Wilson AJ, Mann FA, Murphy WA Jr, Monsees BS, Linn MR. Photostimulable phosphor digital radiography of the extremities: diagnostic accuracy compared with conventional radiography. AJR 1991; 157:533-538.
    • (1991) AJR , vol.157 , pp. 533-538
    • Wilson, A.J.1    Mann, F.A.2    Murphy Jr., W.A.3    Monsees, B.S.4    Linn, M.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.