메뉴 건너뛰기




Volumn 10, Issue 1, 1997, Pages 41-51

Experimental and numerically modeled effects of altered loading conditions on pulmonary venous flow and left atrial pressure in patients with mitral regurgitation

Author keywords

[No Author keywords available]

Indexed keywords

GLYCERYL TRINITRATE; NITROPRUSSIDE SODIUM; PHENYLEPHRINE; VASOCONSTRICTOR AGENT;

EID: 0030636008     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0894-7317(97)80031-4     Document Type: Article
Times cited : (14)

References (25)
  • 1
    • 0025765247 scopus 로고
    • Effect of mitral regurgitation on pulmonary venous flow velocities derived from transesophageal echocardiography color guided pulsed Doppler imaging
    • Castello R, Pearson A, Lenzen P, Labovitz R. Effect of mitral regurgitation on pulmonary venous flow velocities derived from transesophageal echocardiography color guided pulsed Doppler imaging. J Am Coll Cardiol 1991;17:1499-506.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1499-1506
    • Castello, R.1    Pearson, A.2    Lenzen, P.3    Labovitz, R.4
  • 2
    • 0026482393 scopus 로고
    • Effects of mitral regurgitation on pulmonary venous flow and left atrial pressure: An intraoperative transesophageal echocardiographic study
    • Klein A, Stewart W, Barrlett J, Cohen GI, Kahan E, Pearce G, et al. Effects of mitral regurgitation on pulmonary venous flow and left atrial pressure: an intraoperative transesophageal echocardiographic study. J Am Coll Cardiol 1992;20:1345-52.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1345-1352
    • Klein, A.1    Stewart, W.2    Barrlett, J.3    Cohen, G.I.4    Kahan, E.5    Pearce, G.6
  • 3
    • 0025914814 scopus 로고
    • Transesophageal Doppler echocardiography of pulmonary venous flow: A new marker of mitral regurgitation severity
    • Klein AL, Obarski TP, Stewart WJ, Casale PN, Pearce GL, Husbands K, et al. Transesophageal Doppler echocardiography of pulmonary venous flow: a new marker of mitral regurgitation severity. J Am Coll Cardiol 1991;18:518-26.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 518-526
    • Klein, A.L.1    Obarski, T.P.2    Stewart, W.J.3    Casale, P.N.4    Pearce, G.L.5    Husbands, K.6
  • 5
    • 0026197022 scopus 로고
    • Doppler assessment of pulmonary venous flow in healthy subjects and in patients with heart disease
    • Klein A, Tajik A. Doppler assessment of pulmonary venous flow in healthy subjects and in patients with heart disease. J Am Soc Echocardioer 1991;4:379-92.
    • (1991) J Am Soc Echocardioer , vol.4 , pp. 379-392
    • Klein, A.1    Tajik, A.2
  • 6
    • 0025239151 scopus 로고
    • Relation of pulmonary vein to mitral flow velocities by transesophageal Doppler echocardiography: Effect of different loading conditions
    • Nishimura RA, Abel MD, Harle LK, Tajik AJ. Relation of pulmonary vein to mitral flow velocities by transesophageal Doppler echocardiography: effect of different loading conditions. Circulation 1990;81:1488-97.
    • (1990) Circulation , vol.81 , pp. 1488-1497
    • Nishimura, R.A.1    Abel, M.D.2    Harle, L.K.3    Tajik, A.J.4
  • 7
    • 0026639554 scopus 로고
    • Influence of loading conditions and contractile state on pulmonary venous flow
    • Hoit BD, Shao Y, Gabel M, Walsh RA. Influence of loading conditions and contractile state on pulmonary venous flow. Circulation 1992;86:651-9.
    • (1992) Circulation , vol.86 , pp. 651-659
    • Hoit, B.D.1    Shao, Y.2    Gabel, M.3    Walsh, R.A.4
  • 8
    • 0023812780 scopus 로고
    • Transesophageal echocardiography: Technique, anatomic correlations, implementation, and clinical applications
    • Seward JB, Khandheria BK, Oh JK, Abel MD, Hughes RW Jr, Edwards WD, et al. Transesophageal echocardiography: technique, anatomic correlations, implementation, and clinical applications. Mayo Clin Proc 1988;63:649-80.
    • (1988) Mayo Clin Proc , vol.63 , pp. 649-680
    • Seward, J.B.1    Khandheria, B.K.2    Oh, J.K.3    Abel, M.D.4    Hughes Jr., R.W.5    Edwards, W.D.6
  • 9
    • 0019447545 scopus 로고
    • A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography
    • Quinones MA, Waggener AD, Reduto LA, Nelson JG, Young JB, Winters WL Jr, et al. A new, simplified and accurate method for determining ejection fraction with two-dimensional echocardiography. Circulation 1981;64:744-53.
    • (1981) Circulation , vol.64 , pp. 744-753
    • Quinones, M.A.1    Waggener, A.D.2    Reduto, L.A.3    Nelson, J.G.4    Young, J.B.5    Winters Jr., W.L.6
  • 10
    • 0025037551 scopus 로고
    • Intraoperative Doppler color flow mapping for decision making in valve repair for mitral regurgitation: Technique and results in 100 patients
    • Stewart WJ, Currie PJ, Salcedo EE, Lytle BL, Gill CC, Schiavone WA, et al. Intraoperative Doppler color flow mapping for decision making in valve repair for mitral regurgitation: technique and results in 100 patients. Circulation 1990;81:556-66.
    • (1990) Circulation , vol.81 , pp. 556-566
    • Stewart, W.J.1    Currie, P.J.2    Salcedo, E.E.3    Lytle, B.L.4    Gill, C.C.5    Schiavone, W.A.6
  • 11
    • 0025560980 scopus 로고
    • Assessment of mitral regurgitation by biplane transesophageal color Doppler flow mapping
    • Yoshida K, Yoshikawa J, Yamaura Y, Hozumi T, Akasaka T, Kukada T. Assessment of mitral regurgitation by biplane transesophageal color Doppler flow mapping. Circulation 1990;82:1121-6.
    • (1990) Circulation , vol.82 , pp. 1121-1126
    • Yoshida, K.1    Yoshikawa, J.2    Yamaura, Y.3    Hozumi, T.4    Akasaka, T.5    Kukada, T.6
  • 12
    • 0026533802 scopus 로고
    • Evaluation of the severity of mitral regurgitation by transesophageal Doppler flow echocardiography
    • Sadoshima J, Koyanagi S, Sugimachi M, Hirooka Y, Takeshita A. Evaluation of the severity of mitral regurgitation by transesophageal Doppler flow echocardiography. Am Heart J 1992;123:1245-51.
    • (1992) Am Heart J , vol.123 , pp. 1245-1251
    • Sadoshima, J.1    Koyanagi, S.2    Sugimachi, M.3    Hirooka, Y.4    Takeshita, A.5
  • 13
    • 0025764205 scopus 로고
    • Influence of ventricular loading, compliance, and relaxation on transmitral velocity: Hydrodynamic and numerical analysis
    • Thomas JD, Newell JB, Choong CYP, Weyman AE. Influence of ventricular loading, compliance, and relaxation on transmitral velocity: hydrodynamic and numerical analysis. Am J Physiol 1991;260:H1718-30.
    • (1991) Am J Physiol , vol.260
    • Thomas, J.D.1    Newell, J.B.2    Choong, C.Y.P.3    Weyman, A.E.4
  • 14
    • 0026771274 scopus 로고
    • Numerical modeling of ventricular filling
    • Thomas JD. Numerical modeling of ventricular filling. Ann Biomed Eng 1992;20:19-39.
    • (1992) Ann Biomed Eng , vol.20 , pp. 19-39
    • Thomas, J.D.1
  • 16
    • 0023388292 scopus 로고
    • Color Doppler echocardiographic assessment of the change in the mitral regurgitant volume
    • Otsuji Y, Tei C., Kisanuki A, Natsugoe K, Kawazoe Y. Color Doppler echocardiographic assessment of the change in the mitral regurgitant volume. Am Heart J 1987;114:349-54.
    • (1987) Am Heart J , vol.114 , pp. 349-354
    • Otsuji, Y.1    Tei, C.2    Kisanuki, A.3    Natsugoe, K.4    Kawazoe, Y.5
  • 17
    • 0019126591 scopus 로고
    • Effect of nitroglycerin ointment on hemodynamics in patients with mitral insufficiency
    • Gould L, Reddy CVR, Zen B, Singh BK. Effect of nitroglycerin ointment on hemodynamics in patients with mitral insufficiency. Angiology 1980;31:677-85.
    • (1980) Angiology , vol.31 , pp. 677-685
    • Gould, L.1    Reddy, C.V.R.2    Zen, B.3    Singh, B.K.4
  • 20
    • 0025354320 scopus 로고
    • Intraoperative assessment of pulmonary vein flow
    • Orihashi K, Goldiner P, Oka Y. Intraoperative assessment of pulmonary vein flow. Echocardiography 1990;7:261-71.
    • (1990) Echocardiography , vol.7 , pp. 261-271
    • Orihashi, K.1    Goldiner, P.2    Oka, Y.3
  • 21
    • 0027568214 scopus 로고
    • Importance of sampling both pulmonary veins in grading mitral regurgitation by transesophageal echocardiography
    • Klein A, Bailey A, Cohen G, Stewart WJ, Duffy CI, Pearce GL, et al. Importance of sampling both pulmonary veins in grading mitral regurgitation by transesophageal echocardiography. J Am Soc Echocardiogr 1993;6:115-23.
    • (1993) J Am Soc Echocardiogr , vol.6 , pp. 115-123
    • Klein, A.1    Bailey, A.2    Cohen, G.3    Stewart, W.J.4    Duffy, C.I.5    Pearce, G.L.6
  • 22
    • 0029397364 scopus 로고
    • Effect of technical factors on quality of pulmonary venous flow for transverse and longitudinal imaging planes using transesophageal echocardiography
    • Klein AL, Murray RD, Grimm RA, Bailey AS, Black IW, Piedmonte M. Effect of technical factors on quality of pulmonary venous flow for transverse and longitudinal imaging planes using transesophageal echocardiography. J Am Soc Echocardiogr 1995;8:879-87.
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 879-887
    • Klein, A.L.1    Murray, R.D.2    Grimm, R.A.3    Bailey, A.S.4    Black, I.W.5    Piedmonte, M.6
  • 23
    • 0025737199 scopus 로고
    • Impact of impinging wall jet on color Doppler quantification of mitral regurgitation
    • Chen C, Thomas JD, Aconina J, Harrigan P, Mueller L, Picard MH, et al. Impact of impinging wall jet on color Doppler quantification of mitral regurgitation. Circulation 1991;84:712-20.
    • (1991) Circulation , vol.84 , pp. 712-720
    • Chen, C.1    Thomas, J.D.2    Aconina, J.3    Harrigan, P.4    Mueller, L.5    Picard, M.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.