메뉴 건너뛰기




Volumn 166, Issue 2, 1997, Pages 159-161

Spiral CT and 3 D reconstruction of the tracheobronchial tree for individual double-lumen-tube-selection;Spiral-CT and 3 D-Rekonstruktion des Tracheobronchialbaumes zur Auswahl geeigneter Doppellumen-tuben vor Einzellungenbeatmung

Author keywords

computed tomography (CT), helical; computed tomography (CT), three dimensional; intubation, intratracheal; respiration, artificial

Indexed keywords

ARTICLE; ASSISTED VENTILATION; CATHETER; CLINICAL ARTICLE; CONTROLLED STUDY; HUMAN; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; TRACHEOBRONCHIAL TREE; ADULT; ARTIFICIAL VENTILATION; BRONCHOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; ENDOTRACHEAL INTUBATION; INSTRUMENTATION; METHODOLOGY; PREOPERATIVE CARE; RADIOGRAPHY; REPRODUCIBILITY; TRACHEA;

EID: 0030610774     PISSN: 09366652     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (5)
  • 1
    • 0023449789 scopus 로고
    • Margin of safty in positioning modern double-lumen endotracheal tubes
    • Benumof, J. L., B. L. Patridge, C. Salvatierra, J. Keating: Margin of safty in positioning modern double-lumen endotracheal tubes. Anesthesiology 67 (1987) 729-738
    • (1987) Anesthesiology , vol.67 , pp. 729-738
    • Benumof, J.L.1    Patridge, B.L.2    Salvatierra, C.3    Keating, J.4
  • 2
    • 0342733711 scopus 로고
    • In-vitro-Untersuchungen zur Genauigkeit der CT-Angiographie mit 3 D-Nachbearbeitung
    • Kämmerer, M., P. Mildenberger, H.-U. Kauczor, B. Nafe: In-vitro-Untersuchungen zur Genauigkeit der CT-Angiographie mit 3 D-Nachbearbeitung. Fortschr. Röntgenstr. 161 (1994) 275
    • (1994) Fortschr. Röntgenstr. , vol.161 , pp. 275
    • Kämmerer, M.1    Mildenberger, P.2    Kauczor, H.-U.3    Nafe, B.4
  • 3
    • 0026055122 scopus 로고
    • Three-dimensional volumetric display of CT data: Effect of scan parameters upon image quality
    • Ney, D. R., E. K. Fishman, D. Magid, D. D. Robertson, A. Kawashima: Three-dimensional volumetric display of CT data: Effect of scan parameters upon image quality. J. Comput. Assist. Tomogr. 15 (1991) 875-885
    • (1991) J. Comput. Assist. Tomogr. , vol.15 , pp. 875-885
    • Ney, D.R.1    Fishman, E.K.2    Magid, D.3    Robertson, D.D.4    Kawashima, A.5
  • 4
    • 0024441076 scopus 로고
    • Fiberoptic bronchoscopic positioning of double-lumen tubes
    • Slinger, P. D.: Fiberoptic bronchoscopic positioning of double-lumen tubes. J. Cardiothorac. Anesth. 3 (1989) 486-496
    • (1989) J. Cardiothorac. Anesth. , vol.3 , pp. 486-496
    • Slinger, P.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.