메뉴 건너뛰기




Volumn 43, Issue 5, 1997, Pages

Comparison of the closing dynamic of mechanical prosthetic heart valves

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; BIOPROSTHESIS; BLOOD FLOW; CONFERENCE PAPER; HEART VALVE PROSTHESIS; HEART VALVE SURGERY; VIDEORECORDING; X RAY ANALYSIS; ARTICLE; BIOLOGICAL MODEL; BIOMEDICAL ENGINEERING; COMPARATIVE STUDY; HEMODYNAMICS; HEMOLYSIS; HUMAN; IN VITRO STUDY; INSTRUMENTATION; MITRAL VALVE; MOTION;

EID: 0030609281     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (8)
  • 1
    • 0027328079 scopus 로고
    • Cavitation threshold with respect to dP/dt: Evaluation in 29 mm bileaflet, pyrolytic carbon heart valves
    • Kingsbury C, Kafesjian R, Guo G, et al: Cavitation threshold with respect to dP/dt: evaluation in 29 mm bileaflet, pyrolytic carbon heart valves. Int J Artif Organs 16: 515-520, 1993.
    • (1993) Int J Artif Organs , vol.16 , pp. 515-520
    • Kingsbury, C.1    Kafesjian, R.2    Guo, G.3
  • 3
    • 0028533807 scopus 로고
    • A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis
    • Bluestein D, Einav S, Hwang NHC: A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis. J Biomech 27: 1369-1378, 1994.
    • (1994) J Biomech , vol.27 , pp. 1369-1378
    • Bluestein, D.1    Einav, S.2    Nhc, H.3
  • 4
    • 0343215632 scopus 로고    scopus 로고
    • X-ray high speed video camera for measurement of the motion of the implanted mechanical heart valve prostheses
    • Naemura K, Ota Y, Fujim, Umeza M, Matsumoto H, De: X-ray high speed video camera for measurement of the motion of the implanted mechanical heart valve prostheses. Int J Artif Organs 19: 537, 1996.
    • (1996) Int J Artif Organs , vol.19 , pp. 537
    • Naemura, K.1    Ota, Y.2    Fujim3    Umeza, M.4    De Matsumoto, H.5
  • 5
    • 0025473094 scopus 로고
    • Estimation of the rotational undamped natural frequency of bileaflet cardiac valve prostheses
    • Reif TH, Schulte TJ, Hwang NHC: Estimation of the rotational undamped natural frequency of bileaflet cardiac valve prostheses. ASME J Biomech Eng 112: 327-332, 1990.
    • (1990) ASME J Biomech Eng , vol.112 , pp. 327-332
    • Reif, T.H.1    Schulte, T.J.2    Hwang, N.H.C.3
  • 6
    • 0028533242 scopus 로고
    • Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase
    • Cheon GJ, Chandran KB: Transient behavior analysis of a mechanical monoleaflet heart valve prosthesis in the closing phase. ASME J Biomech Eng 116: 452-459, 1994.
    • (1994) ASME J Biomech Eng , vol.116 , pp. 452-459
    • Cheon, G.J.1    Chandran, K.B.2
  • 7
    • 0030888896 scopus 로고    scopus 로고
    • Study on the effect of atrial contraction on mitral prosthetic valve by high speed video camera
    • Naemura K, Sonderegger M, Matsumoto H, et al: Study on the effect of atrial contraction on mitral prosthetic valve by high speed video camera. Artif Organs 21: 300-305, 1997.
    • (1997) Artif Organs , vol.21 , pp. 300-305
    • Naemura, K.1    Sonderegger, M.2    Matsumoto, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.