메뉴 건너뛰기




Volumn 161, Issue 2, 1997, Pages 171-175

Gender and age differenses in transthoracic bioimpedance

Author keywords

Age; Females; Males; Sex; Transthoracic bioimpedance

Indexed keywords

ADULT; AGE; AGED; AORTA FLOW; ARTICLE; CONTROLLED STUDY; FEMALE; HEART CYCLE; HEART OUTPUT; HEART STROKE VOLUME; HUMAN; HUMAN EXPERIMENT; IMPEDANCE; IMPEDANCE CARDIOGRAPHY; MALE; NORMAL HUMAN; PRIORITY JOURNAL; SEX DIFFERENCE; TECHNIQUE; AGING; BODY HEIGHT; BODY WEIGHT; CLINICAL TRIAL; MIDDLE AGED; PHYSIOLOGY; REFERENCE VALUE; SEXUAL DEVELOPMENT; STANDARD;

EID: 0030609082     PISSN: 00016772     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-201X.1997.d01-1949.x     Document Type: Article
Times cited : (5)

References (29)
  • 1
    • 13144271438 scopus 로고
    • Cardiac output during submaximal and maximal work
    • Åstrand, P., Cuddy, T., Saltin, B. & Stenberg, J. 1964. Cardiac output during submaximal and maximal work. J Appl Physiol 19, 268-274.
    • (1964) J Appl Physiol , vol.19 , pp. 268-274
    • Åstrand, P.1    Cuddy, T.2    Saltin, B.3    Stenberg, J.4
  • 2
    • 0022980897 scopus 로고
    • A new stroke volume equation for thoracic electrical bioimpedance. Theory and rationale
    • Bernstein, D. 1986. A new stroke volume equation for thoracic electrical bioimpedance. Theory and rationale. Critical Care Med 14, 904-909.
    • (1986) Critical Care Med , vol.14 , pp. 904-909
    • Bernstein, D.1
  • 3
    • 0027201173 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output - Not ready for prime time
    • Clarke, D. & Raffin, T. 1993. Thoracic electrical bioimpedance measurement of cardiac output - not ready for prime time. Critical Care Medicine 21, 1111-1112.
    • (1993) Critical Care Medicine , vol.21 , pp. 1111-1112
    • Clarke, D.1    Raffin, T.2
  • 4
    • 0019425870 scopus 로고
    • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography
    • Djordjevich, L. & Sadove, M. 1981. Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography. Med Phys 8, 76-78.
    • (1981) Med Phys , vol.8 , pp. 76-78
    • Djordjevich, L.1    Sadove, M.2
  • 5
    • 0000040267 scopus 로고
    • The radiographic appearance of chest in persons of advanced age
    • Edge, J., Millard, F., Reid, L. & Simon, J. 1978. The radiographic appearance of chest in persons of advanced age. Brit J Radiol 37, 769-774.
    • (1978) Brit J Radiol , vol.37 , pp. 769-774
    • Edge, J.1    Millard, F.2    Reid, L.3    Simon, J.4
  • 6
    • 0020364164 scopus 로고
    • Transthoracic impedance: Differences between men and women with implications for impedance cardiography
    • Frey, M., Doerr, B. & Miles, D. 1982. Transthoracic impedance: Differences between men and women with implications for impedance cardiography. Anat Space Environ Med 53, 1190-1192.
    • (1982) Anat Space Environ Med , vol.53 , pp. 1190-1192
    • Frey, M.1    Doerr, B.2    Miles, D.3
  • 7
    • 0014088178 scopus 로고
    • The specific resistance of biological material. A compendium of data for the biomedical engineer and physiologist
    • Geddes, L. & Baker, L. 1967. The specific resistance of biological material. A compendium of data for the biomedical engineer and physiologist. Med Biol Eng 9, 271-293.
    • (1967) Med Biol Eng , vol.9 , pp. 271-293
    • Geddes, L.1    Baker, L.2
  • 9
    • 0019935632 scopus 로고
    • Maximal cardiac function in sedentary normal men and women: Comparison of age-related changes
    • Hossack, K. & Bruce, R. 1982. Maximal cardiac function in sedentary normal men and women: comparison of age-related changes. J Appl Plysiol 53, S794-S804.
    • (1982) J Appl Plysiol , vol.53
    • Hossack, K.1    Bruce, R.2
  • 10
    • 0014764756 scopus 로고
    • Physiological correlates of the cardiac thoracic impedance waveform
    • Karnegis, J. & Kubicek, W. 1970. Physiological correlates of the cardiac thoracic impedance waveform. Am Heart J 79, 519-523.
    • (1970) Am Heart J , vol.79 , pp. 519-523
    • Karnegis, J.1    Kubicek, W.2
  • 11
    • 0013595447 scopus 로고
    • Thoracic cage measurements. Impedance plethysmographic determination of cardiac output
    • School of Aerospace Medicine, Alexandria, VA, USA
    • Kinnen, E., Kubicek, W. & Patterson, R. 1964. Thoracic cage measurements. Impedance plethysmographic determination of cardiac output. Technical Report TDR-64-15. School of Aerospace Medicine, Alexandria, VA, USA.
    • (1964) Technical Report TDR-64-15
    • Kinnen, E.1    Kubicek, W.2    Patterson, R.3
  • 12
    • 0017592228 scopus 로고
    • Effect of aging alone on the mechanical properties of the adult human lung
    • Knudson, R., Clark, D., Kennedy, T. & Knudson, D. 1977. Effect of aging alone on the mechanical properties of the adult human lung. J Appl Physiol 43, 1054-1062.
    • (1977) J Appl Physiol , vol.43 , pp. 1054-1062
    • Knudson, R.1    Clark, D.2    Kennedy, T.3    Knudson, D.4
  • 13
    • 84981642933 scopus 로고
    • Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system
    • Kubicek, W., Patterson, R. & Witsoe, D. 1970. Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system. Ann NY Acad Sci 170, 724-732.
    • (1970) Ann NY Acad Sci , vol.170 , pp. 724-732
    • Kubicek, W.1    Patterson, R.2    Witsoe, D.3
  • 15
    • 0019644501 scopus 로고
    • An analysis of impedance cardiography in the elderly
    • Lye, M. & Vargas, E. 1981. An analysis of impedance cardiography in the elderly. J Med Eng Tech 5, 289-292.
    • (1981) J Med Eng Tech , vol.5 , pp. 289-292
    • Lye, M.1    Vargas, E.2
  • 16
    • 0021123787 scopus 로고
    • Sex differences in transthoracic impedance: Evaluation of effects on calculated stroke volume index
    • McKinney, M., Buell, J. & Eliot, R. 1984. Sex differences in transthoracic impedance: Evaluation of effects on calculated stroke volume index. Ariat Space Environ Med 55, 893-895.
    • (1984) Ariat Space Environ Med , vol.55 , pp. 893-895
    • McKinney, M.1    Buell, J.2    Eliot, R.3
  • 20
    • 0022130871 scopus 로고
    • Sources of the thoracic cardiogenic electrical impedance signal as determined by a model
    • Patterson, R. 1985. Sources of the thoracic cardiogenic electrical impedance signal as determined by a model. Med Biol Eng Comput 23, 411-417.
    • (1985) Med Biol Eng Comput , vol.23 , pp. 411-417
    • Patterson, R.1
  • 21
    • 0029912884 scopus 로고    scopus 로고
    • 2) method of measuring cardiac output in healthy children during excercise
    • 2) method of measuring cardiac output in healthy children during excercise. Am J Cardiol 77, 745-749.
    • (1996) Am J Cardiol , vol.77 , pp. 745-749
    • Pianosi, P.1    Garros, D.2
  • 22
    • 0026651625 scopus 로고
    • Validity of cardiac output measurement by computer-average impedance cardiography, and comparison with simultaneous thermodilution determinations
    • Pickett, B. & Buell, J. 1992. Validity of cardiac output measurement by computer-average impedance cardiography, and comparison with simultaneous thermodilution determinations. Am J Cardiol 69, 1354-1358.
    • (1992) Am J Cardiol , vol.69 , pp. 1354-1358
    • Pickett, B.1    Buell, J.2
  • 23
    • 0013160297 scopus 로고
    • Fibrous network of the lung and its change with age
    • Pierce, J. & Ebert, R. 1965. Fibrous network of the lung and its change with age. Thorax 20, 469-475.
    • (1965) Thorax , vol.20 , pp. 469-475
    • Pierce, J.1    Ebert, R.2
  • 24
    • 0001952126 scopus 로고
    • Stroke volume equation with a linear base model and its accuracy, as compared to thermodilution and magnetic flowmeter techniques in humans and animais
    • Zadar, Yugoslavia
    • Sramek, B., Rose, D. & Miyamoto, A. 1983. Stroke volume equation with a linear base model and its accuracy, as compared to thermodilution and magnetic flowmeter techniques in humans and animais. Proceedings of the 6th International Conference on Electrical Bioimpedance, pp 38-41. Zadar, Yugoslavia.
    • (1983) Proceedings of the 6th International Conference on Electrical Bioimpedance , pp. 38-41
    • Sramek, B.1    Rose, D.2    Miyamoto, A.3
  • 25
    • 0026613990 scopus 로고
    • Impedance cardiography using the Sramek-Bernstein method: Accuracy and variability at rest and during excercise
    • Thomas, S. 1992. Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during excercise. BrJ Clin Pharmac 34, 467-476.
    • (1992) BrJ Clin Pharmac , vol.34 , pp. 467-476
    • Thomas, S.1
  • 26
    • 0018920830 scopus 로고
    • Impedance caidiography and cardiac output in the elderly
    • Williams, B. & Caird, F. 1980. Impedance caidiography and cardiac output in the elderly. Age Aging 9, 47-52.
    • (1980) Age Aging , vol.9 , pp. 47-52
    • Williams, B.1    Caird, F.2
  • 27
    • 0021837654 scopus 로고
    • Accuracy of the impedance cardiogram in the measurement of cardiac output in the elderly
    • Williams, B. & Caird, F. 1985. Accuracy of the impedance cardiogram in the measurement of cardiac output in the elderly. Age Aging 14, 279-281.
    • (1985) Age Aging , vol.14 , pp. 279-281
    • Williams, B.1    Caird, F.2
  • 28
    • 0014089433 scopus 로고
    • Electrical resistivity of lung at 100 kHz
    • Witsoe, D. 1967. Electrical resistivity of lung at 100 kHz. Med Biol Eng 51, 239-248.
    • (1967) Med Biol Eng , vol.51 , pp. 239-248
    • Witsoe, D.1
  • 29
    • 0029003059 scopus 로고
    • Evaluation of impedance cardiography: Comparison of NCCOM3 - R7 with Pick and thermodilution methods
    • Yakimets, J. & fensen, L. 1995. Evaluation of impedance cardiography: comparison of NCCOM3 - R7 with Pick and thermodilution methods. Heart Lung 24, 194-206.
    • (1995) Heart Lung , vol.24 , pp. 194-206
    • Yakimets, J.1    Fensen, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.