메뉴 건너뛰기




Volumn 83, Issue 3, 1996, Pages 211-218

Estimation of carboxyhemoglobin concentrations in thermo-coagulated blood on a CO-oximeter system: An experimental study

Author keywords

Blood; Carboxyhemoglobin; Co oximeter; Forensic toxicology; Thermo coagulation

Indexed keywords

CARBOXYHEMOGLOBIN;

EID: 0030604295     PISSN: 03790738     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0379-0738(96)02039-7     Document Type: Article
Times cited : (17)

References (16)
  • 1
    • 0019230982 scopus 로고
    • A new instrument for the simultaneous measurement of total hemoglobin, % oxyhemoglobin, % carboxyhemoglobin, % methemoglobin and oxygen content in whole blood
    • [1] L.J. Brown, A new instrument for the simultaneous measurement of total hemoglobin, % oxyhemoglobin, % carboxyhemoglobin, % methemoglobin and oxygen content in whole blood. IEEE Trans. Biomed. Eng., 27 (1980) 132-138.
    • (1980) IEEE Trans. Biomed. Eng. , vol.27 , pp. 132-138
    • Brown, L.J.1
  • 3
    • 0014994698 scopus 로고
    • Carbon monoxide determination in postmortem clotted blood
    • [3] A.W. Freireich and D. Landau, Carbon monoxide determination in postmortem clotted blood. J. Forensic Sci., 16 (1971) 112-119.
    • (1971) J. Forensic Sci. , vol.16 , pp. 112-119
    • Freireich, A.W.1    Landau, D.2
  • 4
    • 0024495744 scopus 로고
    • Study on the effects of heat on blood and on the post-mortem estimation of carboxyhaemoglobin and methaemoglobin
    • [4] G.G.P. Fechner and D.J. Gee, Study on the effects of heat on blood and on the post-mortem estimation of carboxyhaemoglobin and methaemoglobin. Forensic Sci. Int., 40 (1989) 63-67.
    • (1989) Forensic Sci. Int. , vol.40 , pp. 63-67
    • Fechner, G.G.P.1    Gee, D.J.2
  • 5
    • 0002977590 scopus 로고    scopus 로고
    • Applicability of a CO-oximeter to analysis of carboxyhemoglobin in thermo-changed blood: Experimental study on two different systems
    • [5] H. Maeda, K. Noguchi, S. Oritani, K. Nagai and B.-L. Zhu, Applicability of a CO-oximeter to analysis of carboxyhemoglobin in thermo-changed blood: experimental study on two different systems. Jpn. J. Forensic Toxicol., 14 (1996) 35-42.
    • (1996) Jpn. J. Forensic Toxicol. , vol.14 , pp. 35-42
    • Maeda, H.1    Noguchi, K.2    Oritani, S.3    Nagai, K.4    Zhu, B.-L.5
  • 6
    • 0019832524 scopus 로고
    • Determination of carboxyhemoglobin saturation in blood and body cavity fluids by carbon monoxide and total hemoglobin concentrations
    • [6] T. Kojima, Y. Nishiyama, M. Yashiki and I. Une, Determination of carboxyhemoglobin saturation in blood and body cavity fluids by carbon monoxide and total hemoglobin concentrations. Jpn. J. Leg. Med., 35 (1981) 305-311.
    • (1981) Jpn. J. Leg. Med. , vol.35 , pp. 305-311
    • Kojima, T.1    Nishiyama, Y.2    Yashiki, M.3    Une, I.4
  • 7
    • 0011376808 scopus 로고
    • A simple and high-sensitive method for determination of carbon monoxide in blood by gas chromatography
    • [7] Y. Katsumata, K. Sato and S. Yada, A simple and high-sensitive method for determination of carbon monoxide in blood by gas chromatography. Acta Criminol. Japon., 51 (1985) 139-144.
    • (1985) Acta Criminol. Japon. , vol.51 , pp. 139-144
    • Katsumata, Y.1    Sato, K.2    Yada, S.3
  • 8
    • 0020590865 scopus 로고
    • A new reagent for the rapid determination of total hemoglobin as hemiglobincyanide in blood containing carboxyhemoglobin
    • [8] K. Sato, Y. Katsumata, M. Aoki, O. Suzuki, A. Kido, M. Oya and S. Yada, A new reagent for the rapid determination of total hemoglobin as hemiglobincyanide in blood containing carboxyhemoglobin. Biochem. Med., 30 (1983) 78-88.
    • (1983) Biochem. Med. , vol.30 , pp. 78-88
    • Sato, K.1    Katsumata, Y.2    Aoki, M.3    Suzuki, O.4    Kido, A.5    Oya, M.6    Yada, S.7
  • 9
    • 0016717276 scopus 로고
    • Carbon monoxide determination in postmortem heated rat blood
    • [9] C. Miyauchi and K. Sakaki, Carbon monoxide determination in postmortem heated rat blood. Jpn. J. Leg. Med., 29 (1975) 22-26.
    • (1975) Jpn. J. Leg. Med. , vol.29 , pp. 22-26
    • Miyauchi, C.1    Sakaki, K.2
  • 10
    • 0018950923 scopus 로고
    • Effect of heating on CO content in the blood, an in vitro study
    • [10] K. Yamamoto and C. Kuwahara, Effect of heating on CO content in the blood, an in vitro study. Z. Rechtsmed., 85 (1980) 275-281.
    • (1980) Z. Rechtsmed. , vol.85 , pp. 275-281
    • Yamamoto, K.1    Kuwahara, C.2
  • 11
    • 0019857176 scopus 로고
    • Changes of contents of CO and water in blood exposed to heat: As to a possibility of estimating pre-exposure CO content of thermally coagulated blood on the basis of its water content
    • [11] K. Yamamoto and C. Kuwahara, Changes of contents of CO and water in blood exposed to heat: as to a possibility of estimating pre-exposure CO content of thermally coagulated blood on the basis of its water content. Z. Rechtsmed., 87 (1981) 237-242.
    • (1981) Z. Rechtsmed. , vol.87 , pp. 237-242
    • Yamamoto, K.1    Kuwahara, C.2
  • 12
    • 0021954428 scopus 로고
    • Effect of heating on methemoglobin content in the blood
    • [12] J. Shigezane, Effect of heating on methemoglobin content in the blood. Jpn. J. Leg. Med., 39 (1985) 1-5.
    • (1985) Jpn. J. Leg. Med. , vol.39 , pp. 1-5
    • Shigezane, J.1
  • 13
    • 0021991453 scopus 로고
    • Determination of carboxyhemoglobin in heated blood: Sources of error and utility of derivative spectrophotometry
    • [13] Y. Fukui, M. Matsubara, A. Akane, K. Hama, K. Matsubara and S. Takahashi, Determination of carboxyhemoglobin in heated blood: sources of error and utility of derivative spectrophotometry. J. Anal. Toxicol., 9 (1985) 81-84.
    • (1985) J. Anal. Toxicol. , vol.9 , pp. 81-84
    • Fukui, Y.1    Matsubara, M.2    Akane, A.3    Hama, K.4    Matsubara, K.5    Takahashi, S.6
  • 14
    • 0014425482 scopus 로고
    • Effect of heating of blood on the quantitative determination of carbon monoxide haemoglobin
    • [14] K. Ekbom-Lindholm, Effect of heating of blood on the quantitative determination of carbon monoxide haemoglobin. Dtsch. Z. gerichtl. Med., 63 (1968) 114-117.
    • (1968) Dtsch. Z. Gerichtl. Med. , vol.63 , pp. 114-117
    • Ekbom-Lindholm, K.1
  • 16
    • 0020043392 scopus 로고
    • A simple and accurate method for measurements of the hemoglobin content in blood by colorimetric iron determination
    • [16] Y. Katsumata, K. Sato, M. Aoki, O. Suzuki, M. Oya and S. Yada, A simple and accurate method for measurements of the hemoglobin content in blood by colorimetric iron determination. Z. Rechtsmed., 88 (1983) 27-30.
    • (1983) Z. Rechtsmed. , vol.88 , pp. 27-30
    • Katsumata, Y.1    Sato, K.2    Aoki, M.3    Suzuki, O.4    Oya, M.5    Yada, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.