Volumn 8, Issue 2, 1996, Pages 34-40

The influence of four-bar linkage knees on prosthetic swing-phase floor clearance

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0030558615     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: 10.1097/00008526-199600820-00004     Document Type: Article
Times cited : (54)

References (10)
  • 2
    • 85033810731 scopus 로고
    • Knee components for the above-knee amputation
    • Murdoch G, Donovan RG [eds]. Oxford: Blackwell Scientific Publications
    • Oberg KET, Kamwendo K. Knee components for the above-knee amputation. In: Murdoch G, Donovan RG [eds]. Amputation surgery & lower-limb prosthetics. Oxford: Blackwell Scientific Publications, 1988; 152-64.
    • (1988) Amputation Surgery & Lower-limb Prosthetics , pp. 152-164
    • Oberg, K.E.T.1    Kamwendo, K.2
  • 3
    • 0012428992 scopus 로고
    • Prosthetic-knee mechanisms for above-knee amputees
    • Murdoch G [ed]. London: Edward Arnold Ltd.
    • Radcliffe CW. Prosthetic-knee mechanisms for above-knee amputees. In: Murdoch G [ed]. Prosthetic and orthotic practice. London: Edward Arnold Ltd., 1970; 225-49.
    • (1970) Prosthetic and Orthotic Practice , pp. 225-249
    • Radcliffe, C.W.1
  • 4
    • 0017603855 scopus 로고
    • The Knud Jansen lecture: Above-knee prosthetics
    • Radcliffe CW. The Knud Jansen lecture: above-knee prosthetics. Pros and Orth Int 1977; 1:3:146-60.
    • (1977) Pros and Orth Int , vol.1 , Issue.3 , pp. 146-160
    • Radcliffe, C.W.1
  • 5
    • 0028569228 scopus 로고
    • Four-bar linkage, prosthetic knee mechanisms: Kinematics, alignment and prescription criteria
    • Radcliffe CW. Four-bar linkage, prosthetic knee mechanisms: kinematics, alignment and prescription criteria. Pros and Orth Int 1994; 18:159-73.
    • (1994) Pros and Orth Int , vol.18 , pp. 159-173
    • Radcliffe, C.W.1
  • 6
    • 0021082787 scopus 로고
    • Four-bar linkage knee analysis
    • Greene MP. Four-bar linkage knee analysis. Orth and Pros. 1983; 37:1:15-24.
    • (1983) Orth and Pros , vol.37 , Issue.1 , pp. 15-24
    • Greene, M.P.1
  • 8
    • 0004058126 scopus 로고
    • Wright Air Development Center Technical Report 55-159, U.S. Air Force, Wright-Patterson Air Force Base, Ohio
    • Dempster WT. Space requirements of the seated operator. Wright Air Development Center Technical Report 55-159, U.S. Air Force, Wright-Patterson Air Force Base, Ohio, 1955.
    • (1955) Space Requirements of the Seated Operator
    • Dempster, W.T.1
  • 9
    • 85033811746 scopus 로고
    • Manual for the Prosthetic-Orthotic Center of the Northwestern University Medical School, Chicago
    • Transfemoral prosthetics for prosthetists. Manual for the Prosthetic-Orthotic Center of the Northwestern University Medical School, Chicago, 1995.
    • (1995) Transfemoral Prosthetics for Prosthetists
  • 10
    • 0026573228 scopus 로고
    • Foot trajectory in human gait: A precise and multifactorial motor control task
    • Winter DA. Foot trajectory in human gait: a precise and multifactorial motor control task. Phys Ther 1992; 72:1:55-66
    • (1992) Phys Ther , vol.72 , Issue.1 , pp. 55-66
    • Winter, D.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.