-
1
-
-
0020065518
-
Glomerular filtration rate: Estimation from fractional renal accumulation of Tc-99m DTPA (stanous)
-
Gates GF. Glomerular filtration rate: estimation from fractional renal accumulation of Tc-99m DTPA (stanous). AJR 138: 565-570, 1982.
-
(1982)
AJR
, vol.138
, pp. 565-570
-
-
Gates, G.F.1
-
2
-
-
0020965854
-
Split renal function testing using Tc-99m DTPA: A rapid technique for determining deferential glomerular filtration
-
Gates GF. Split renal function testing using Tc-99m DTPA: A rapid technique for determining deferential glomerular filtration. Clin Nucl Med 8: 400-407, 1983.
-
(1983)
Clin Nucl Med
, vol.8
, pp. 400-407
-
-
Gates, G.F.1
-
3
-
-
0027395003
-
A preliminary phantom study on a proposed model for quantification of renal planar scintigraphy
-
Kojima A, Takaki Y, Matsumoto M, Tomiguchi S, Hara M, Shimomura O, et al. A preliminary phantom study on a proposed model for quantification of renal planar scintigraphy. Med Phys 20: 33-37, 1993.
-
(1993)
Med Phys
, vol.20
, pp. 33-37
-
-
Kojima, A.1
Takaki, Y.2
Matsumoto, M.3
Tomiguchi, S.4
Hara, M.5
Shimomura, O.6
-
4
-
-
0027160125
-
Quantification of renal uptake of technetium-99m-DTPA using planar scintigraphy: A technique that considers organ volume
-
Takaki Y, Kojima A, Tsuji A, Nakashima R, Tomiguchi S, Takahashi M. Quantification of renal uptake of technetium-99m-DTPA using planar scintigraphy: a technique that considers organ volume. J Nucl Med 34: 1184-1189, 1993.
-
(1993)
J Nucl Med
, vol.34
, pp. 1184-1189
-
-
Takaki, Y.1
Kojima, A.2
Tsuji, A.3
Nakashima, R.4
Tomiguchi, S.5
Takahashi, M.6
-
5
-
-
0017156614
-
Interpolative background subtraction
-
Goris ML, Daspit SG, McLaughlin P, Kriss JP. Interpolative background subtraction. J Nucl Med 17: 744-747, 1976.
-
(1976)
J Nucl Med
, vol.17
, pp. 744-747
-
-
Goris, M.L.1
Daspit, S.G.2
McLaughlin, P.3
Kriss, J.P.4
-
6
-
-
0022220840
-
The effect of source size in the buildup factor calculation of absolute volume determination
-
Siegel JA. The effect of source size in the buildup factor calculation of absolute volume determination. J Nucl Med 26: 1319-1322, 1985.
-
(1985)
J Nucl Med
, vol.26
, pp. 1319-1322
-
-
Siegel, J.A.1
-
7
-
-
0023684657
-
Avoidance of errors related to renal depth during radionuclide evaluation of renal perfusion
-
Conrad GR, Wesolowski CA. Avoidance of errors related to renal depth during radionuclide evaluation of renal perfusion. Clin Nucl Med 13: 721-726, 1988.
-
(1988)
Clin Nucl Med
, vol.13
, pp. 721-726
-
-
Conrad, G.R.1
Wesolowski, C.A.2
-
8
-
-
26844490953
-
The application of interpolative background subtraction to Tc-99m DTPA gamma camera renography data
-
Joekes AM, et al., eds. London: Academic Press/Grune and Stratton
-
Brown NJG. The application of interpolative background subtraction to Tc-99m DTPA gamma camera renography data. In: Joekes AM, et al., eds. Radionuclide in Nephrography. London: Academic Press/Grune and Stratton, pp. 113-118, 1982.
-
(1982)
Radionuclide in Nephrography
, pp. 113-118
-
-
Brown, N.J.G.1
-
9
-
-
0027158068
-
The variability of processing of technetium-99m DTPA renography: Role of interpolative background subtraction
-
Hurwitz GA, Champagne CL, Gravelle DR, Smith FJ, Powe JE. The variability of processing of technetium-99m DTPA renography: role of interpolative background subtraction. Clin Nucl Med 18: 273-277, 1993.
-
(1993)
Clin Nucl Med
, vol.18
, pp. 273-277
-
-
Hurwitz, G.A.1
Champagne, C.L.2
Gravelle, D.R.3
Smith, F.J.4
Powe, J.E.5
-
10
-
-
0020508034
-
99mTc DTPA renal studies: A comparison between interpolative background subtraction and surface ratio method
-
99mTc DTPA renal studies: a comparison between interpolative background subtraction and surface ratio method. Nucl Med Commun 4: 276-281, 1983.
-
(1983)
Nucl Med Commun
, vol.4
, pp. 276-281
-
-
Piepsz, A.1
Dobbeleir, A.2
Ham, H.R.3
-
11
-
-
0027232922
-
A pitfall in calculating differential renal function in patients with renal failure
-
Sennewald K, Taylor A. A pitfall in calculating differential renal function in patients with renal failure. Clin Nucl Med 18: 377-381, 1993.
-
(1993)
Clin Nucl Med
, vol.18
, pp. 377-381
-
-
Sennewald, K.1
Taylor, A.2
-
14
-
-
0021274313
-
Glomerular filtration rate in children: Determination from the Tc-99m-DTPA renogram
-
Shore RM, Koff SA, Mentser M, Hayes JR, Smith SP, Smith JP, et al. Glomerular filtration rate in children: determination from the Tc-99m-DTPA renogram. Radiology 151: 627-633, 1984.
-
(1984)
Radiology
, vol.151
, pp. 627-633
-
-
Shore, R.M.1
Koff, S.A.2
Mentser, M.3
Hayes, J.R.4
Smith, S.P.5
Smith, J.P.6
-
15
-
-
0016722177
-
Deconvolution analysis of the scintillation camera renogram
-
Kenny RW, Ackery DM, Fleming JS, Goddard BA, Grant RW. Deconvolution analysis of the scintillation camera renogram. Br J Radiol 48: 481-486, 1975.
-
(1975)
Br J Radiol
, vol.48
, pp. 481-486
-
-
Kenny, R.W.1
Ackery, D.M.2
Fleming, J.S.3
Goddard, B.A.4
Grant, R.W.5
-
17
-
-
0019949814
-
A co-operative study on the clinical value of dynamic renal scanning with deconvolution analysis
-
Piepsz A, Ham HR, Erbsmann F, Hall M, Diffey BL, Goggin MJ, et al. A co-operative study on the clinical value of dynamic renal scanning with deconvolution analysis. Br J Radiol 55: 419-433, 1982.
-
(1982)
Br J Radiol
, vol.55
, pp. 419-433
-
-
Piepsz, A.1
Ham, H.R.2
Erbsmann, F.3
Hall, M.4
Diffey, B.L.5
Goggin, M.J.6
-
18
-
-
0023137366
-
Error analysis by simulation studies in renography deconvolution
-
Gullquist RR, Fleming JS. Error analysis by simulation studies in renography deconvolution. Phys Med Biol 32: 383-395, 1987.
-
(1987)
Phys Med Biol
, vol.32
, pp. 383-395
-
-
Gullquist, R.R.1
Fleming, J.S.2
|