메뉴 건너뛰기




Volumn 276, Issue 21, 1996, Pages 1752-1755

Context bias: A problem in diagnostic radiology

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIOGRAPHY; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; HUMAN; LUNG EMBOLISM; OBSERVER VARIATION; PREVALENCE; PRIORITY JOURNAL; RADIODIAGNOSIS;

EID: 0030477077     PISSN: 00987484     EISSN: None     Source Type: Journal    
DOI: 10.1001/jama.276.21.1752     Document Type: Article
Times cited : (160)

References (28)
  • 1
    • 0023215516 scopus 로고
    • Biases in the assessment of diagnostic tests
    • Begg CB. Biases in the assessment of diagnostic tests. Stat Med. 1987;6:411-423.
    • (1987) Stat Med , vol.6 , pp. 411-423
    • Begg, C.B.1
  • 2
    • 0000397133 scopus 로고
    • The clinical history as a factor in roentgenogram interpretation
    • Schreiber MH. The clinical history as a factor in roentgenogram interpretation. JAMA. 1963;185:137-139.
    • (1963) JAMA , vol.185 , pp. 137-139
    • Schreiber, M.H.1
  • 3
    • 0023739408 scopus 로고
    • PET scans and technology assessment
    • Chalmers TC. PET scans and technology assessment. JAMA. 1988;260:2713-2715.
    • (1988) JAMA , vol.260 , pp. 2713-2715
    • Chalmers, T.C.1
  • 4
    • 0020521749 scopus 로고
    • Paired receiver operating characteristic curves and the effect of history on radiographic interpretation
    • McNeil BJ, Hanley JA, Funkenstein HH, Wallman J. Paired receiver operating characteristic curves and the effect of history on radiographic interpretation. Radiology. 1983;149:75-77.
    • (1983) Radiology , vol.149 , pp. 75-77
    • McNeil, B.J.1    Hanley, J.A.2    Funkenstein, H.H.3    Wallman, J.4
  • 5
    • 0027254478 scopus 로고
    • Effect of clinical history on the interpretation of chest radiographs in childhood bronchiolitis
    • Babcook CJ, Norman GR, Coblentz CL. Effect of clinical history on the interpretation of chest radiographs in childhood bronchiolitis. Invest Radiol. 1993;28:214-217.
    • (1993) Invest Radiol , vol.28 , pp. 214-217
    • Babcook, C.J.1    Norman, G.R.2    Coblentz, C.L.3
  • 8
    • 0025020252 scopus 로고
    • Editorial rumination: The inadequacy of binary models for the clinical reality of three-zone diagnostic decisions
    • Feinstein AR. Editorial rumination: the inadequacy of binary models for the clinical reality of three-zone diagnostic decisions. J Clin Epidemiol. 1990;43:109-113.
    • (1990) J Clin Epidemiol , vol.43 , pp. 109-113
    • Feinstein, A.R.1
  • 9
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. 1982;143:29-36.
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 11
    • 0026648190 scopus 로고
    • Spectrum bias in the evaluation of diagnostic tests: Lessons from the rapid dipstick test for urinary tract infection
    • Lachs MS, Nachamkin I, Edelstein PH, Goldman J, Feinstein AR, Schwartz JS. Spectrum bias in the evaluation of diagnostic tests: lessons from the rapid dipstick test for urinary tract infection. Ann Intern Med. 1992;117:135-140.
    • (1992) Ann Intern Med , vol.117 , pp. 135-140
    • Lachs, M.S.1    Nachamkin, I.2    Edelstein, P.H.3    Goldman, J.4    Feinstein, A.R.5    Schwartz, J.S.6
  • 12
    • 0018178436 scopus 로고
    • Problems of spectrum and bias in evaluating the efficacy of diagnostic tests
    • Ransohoff D, Feinstein A. Problems of spectrum and bias in evaluating the efficacy of diagnostic tests. N Engl J Med. 1978;299:926-930.
    • (1978) N Engl J Med , vol.299 , pp. 926-930
    • Ransohoff, D.1    Feinstein, A.2
  • 15
    • 0022370337 scopus 로고
    • Assessment of diagnostic technologies: Methodology for unbiased estimation from samples of selectively verified patients
    • Greenes RA, Begg CB. Assessment of diagnostic technologies: methodology for unbiased estimation from samples of selectively verified patients. Invest Radiol. 1985;20:751-756.
    • (1985) Invest Radiol , vol.20 , pp. 751-756
    • Greenes, R.A.1    Begg, C.B.2
  • 16
    • 0023001969 scopus 로고
    • Communicating the significance of radiologic test results: The likelihood ratio
    • Black W, Armstrong P. Communicating the significance of radiologic test results: the likelihood ratio. AJR Am J Roentgenol. 1986;147:1313-1318.
    • (1986) AJR Am J Roentgenol , vol.147 , pp. 1313-1318
    • Black, W.1    Armstrong, P.2
  • 17
    • 0028009825 scopus 로고
    • Uncertainty in Bayes
    • Baron JA. Uncertainty in Bayes. Med Decis Making. 1994;14:46-51.
    • (1994) Med Decis Making , vol.14 , pp. 46-51
    • Baron, J.A.1
  • 18
    • 0027135374 scopus 로고
    • Use of the positive predictive value to correct for disease misclassification in epidemiologic studies
    • Brenner H, Gefeller O. Use of the positive predictive value to correct for disease misclassification in epidemiologic studies. Am J Epidemiol. 1993; 138:1007-1015.
    • (1993) Am J Epidemiol , vol.138 , pp. 1007-1015
    • Brenner, H.1    Gefeller, O.2
  • 19
    • 0023931845 scopus 로고
    • The poor quality of early evaluations of magnetic resonance imaging
    • Cooper LS, Chalmers TC, McCally M, Berrier J, Sacks HS. The poor quality of early evaluations of magnetic resonance imaging. JAMA. 1988;259: 3277-3280.
    • (1988) JAMA , vol.259 , pp. 3277-3280
    • Cooper, L.S.1    Chalmers, T.C.2    McCally, M.3    Berrier, J.4    Sacks, H.S.5
  • 21
    • 0019964384 scopus 로고
    • Ten- to fourteen-year effect of screening on breast cancer mortality
    • Shapiro S, Venet W, Strax P, Venet L, Roeser R. Ten- to fourteen-year effect of screening on breast cancer mortality. J Natl Cancer Inst. 1982;69:349-355.
    • (1982) J Natl Cancer Inst , vol.69 , pp. 349-355
    • Shapiro, S.1    Venet, W.2    Strax, P.3    Venet, L.4    Roeser, R.5
  • 22
    • 0020317119 scopus 로고
    • Breast cancer detection demonstration project: Five-year summary report
    • Baker LH. Breast cancer detection demonstration project: five-year summary report. CA Cancer J Clin. 1982;32:194-225.
    • (1982) CA Cancer J Clin , vol.32 , pp. 194-225
    • Baker, L.H.1
  • 24
    • 0030025498 scopus 로고    scopus 로고
    • Early-stage rheumatoid arthritis: Diagnostic accuracy of MR imaging
    • Sugimoto H, Takeda A, Masuyama J-I, Furuse M. Early-stage rheumatoid arthritis: diagnostic accuracy of MR imaging. Radiology. 1996;198:185-192.
    • (1996) Radiology , vol.198 , pp. 185-192
    • Sugimoto, H.1    Takeda, A.2    Masuyama, J.-I.3    Furuse, M.4
  • 25
    • 0030025759 scopus 로고    scopus 로고
    • Detection and differential diagnosis of pulmonary infections and tumors in patients with AIDS: Value of chest radiography versus CT
    • Kang E-Y, Staples CA, McGuinness G, Primack SL, Müller NL. Detection and differential diagnosis of pulmonary infections and tumors in patients with AIDS: value of chest radiography versus CT. AJR Am J Roentgenol. 1996;166:15-19.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 15-19
    • Kang, E.-Y.1    Staples, C.A.2    McGuinness, G.3    Primack, S.L.4    Müller, N.L.5
  • 26
    • 0028841735 scopus 로고
    • Calcification of coronary arteries: Detection and quantification with double helix CT
    • Shemesh J, Apter S, Rozenman J, et al. Calcification of coronary arteries: detection and quantification with double helix CT. Radiology. 1995; 197:779-783.
    • (1995) Radiology , vol.197 , pp. 779-783
    • Shemesh, J.1    Apter, S.2    Rozenman, J.3
  • 27
    • 0029046264 scopus 로고
    • The value of portal vein pulsatility on duplex sonograms as a sign of portal hypertension in children with liver disease
    • Westra SJ, Zaninovic AC, Vargas J, Hall TR, Boechat MI, Busuttil RW. The value of portal vein pulsatility on duplex sonograms as a sign of portal hypertension in children with liver disease. AJR Am J Roentgenol. 1995;165:167-172.
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 167-172
    • Westra, S.J.1    Zaninovic, A.C.2    Vargas, J.3    Hall, T.R.4    Boechat, M.I.5    Busuttil, R.W.6
  • 28


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.