메뉴 건너뛰기




Volumn 22, Issue SUPPL. 2, 1996, Pages 1291-1295

Comparison of two plate-haptic intraocular lenses in a rabbit model

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; CONTROLLED STUDY; FIBROSIS; LENS CAPSULE; LENS IMPLANT; NONHUMAN; PHACOEMULSIFICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RABBIT; SILICONE PROSTHESIS; SURGICAL TECHNIQUE;

EID: 0030470351     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0886-3350(96)80087-3     Document Type: Article
Times cited : (34)

References (10)
  • 1
    • 0029124905 scopus 로고
    • Practice styles and preferences of ASCRS members-1994 survey
    • DV Learning Practice styles and preferences of ASCRS members-1994 survey J Cataract Refract Surg 21 1995 378 385
    • (1995) J Cataract Refract Surg , vol.21 , pp. 378-385
    • Learning, DV1
  • 2
    • 0027008470 scopus 로고
    • Visual, astigmatic, and inflammatory results with the Staar AA-4203 single-piece foldable IOL: a randomized, prospective study
    • RG Martin DR Sanders Visual, astigmatic, and inflammatory results with the Staar AA-4203 single-piece foldable IOL: a randomized, prospective study Ophthalmic Surg 23 1992 770 775
    • (1992) Ophthalmic Surg , vol.23 , pp. 770-775
    • Martin, RG1    Sanders, DR2
  • 3
    • 0029142744 scopus 로고
    • Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes
    • T Kohnen B Dick KW Jacobi Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes J Cataract Refract Surg 21 1995 417 424
    • (1995) J Cataract Refract Surg , vol.21 , pp. 417-424
    • Kohnen, T1    Dick, B2    Jacobi, KW3
  • 4
    • 0026556723 scopus 로고
    • Effect of small incision intraocular lens surgery on postoperative inflammation and astigmatism; a study of the AMO SI-18NB small incision lens
    • RG Martin DR Sanders MA Van Der Karr M DeLuca Effect of small incision intraocular lens surgery on postoperative inflammation and astigmatism; a study of the AMO SI-18NB small incision lens J Cataract Refract Surg 18 1992 51 57
    • (1992) J Cataract Refract Surg , vol.18 , pp. 51-57
    • Martin, RG1    Sanders, DR2    Van Der Karr, MA3    DeLuca, M4
  • 5
    • 0024548995 scopus 로고
    • Induced astigmatism in small incision cataract surgery
    • JR Shepherd Induced astigmatism in small incision cataract surgery J Cataract Refract Surgery 15 1989 85 88
    • (1989) J Cataract Refract Surgery , vol.15 , pp. 85-88
    • Shepherd, JR1
  • 6
    • 0025976247 scopus 로고
    • Keratometric cylinder and visual performance following phacoemulsification and implantation with silicone small-incision or poly (methyl methacrylate) intraocular lenses
    • SF Brint DM Ostrick JE Bryan Keratometric cylinder and visual performance following phacoemulsification and implantation with silicone small-incision or poly (methyl methacrylate) intraocular lenses J Cataract Refract Surg 17 1991 32 36
    • (1991) J Cataract Refract Surg , vol.17 , pp. 32-36
    • Brint, SF1    Ostrick, DM2    Bryan, JE3
  • 7
    • 0025857257 scopus 로고
    • Astigmatism after small incision cataract surgery; a prospective, randomized multicenter comparison of 4- and 6.5-mm incisions
    • RF Steinert SF Brint SM White IH Fine Astigmatism after small incision cataract surgery; a prospective, randomized multicenter comparison of 4- and 6.5-mm incisions Ophthalmology 98 1991 417 423
    • (1991) Ophthalmology , vol.98 , pp. 417-423
    • Steinert, RF1    Brint, SF2    White, SM3    Fine, IH4
  • 8
    • 0027219294 scopus 로고
    • Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses
    • JS Cumming Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lenses J Cataract Refract Surg 19 1993 263 274
    • (1993) J Cataract Refract Surg , vol.19 , pp. 263-274
    • Cumming, JS1
  • 9
    • 0028058889 scopus 로고
    • Capsulotomy rate in silicon plate haptic and Prolene loop IOLs
    • JS Cumming Capsulotomy rate in silicon plate haptic and Prolene loop IOLs Eur J Implant Refract Surg 6 1994 200 204
    • (1994) Eur J Implant Refract Surg , vol.6 , pp. 200-204
    • Cumming, JS1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.