메뉴 건너뛰기




Volumn 27, Issue 9-10, 1996, Pages 2433-2442

Calibration of the time-domain reflectometer and determination of the volumetric water content of the soil profile in an ultisol of Costa Rica

Author keywords

[No Author keywords available]

Indexed keywords

PLANT GROWTH; SOIL LAYER; SOIL PROFILE; SOIL WATER; ULTISOL;

EID: 0030466693     PISSN: 00103624     EISSN: None     Source Type: Journal    
DOI: 10.1080/00103629609369713     Document Type: Article
Times cited : (1)

References (9)
  • 2
    • 24944545515 scopus 로고
    • Comparison of radio frequency, tensiometer and gravimetric soil moisture techniques
    • Niagara Falls, NY, 27-29 October 1980. State University of New York, Buffalo, NY
    • McKlim, H.L., J.E. Walsh, and T. Pangburn. 1980. Comparison of radio frequency, tensiometer and gravimetric soil moisture techniques. Proceedings Third Colloquium on Planetary Water. Niagara Falls, NY, 27-29 October 1980. State University of New York, Buffalo, NY.
    • (1980) Proceedings Third Colloquium on Planetary Water
    • McKlim, H.L.1    Walsh, J.E.2    Pangburn, T.3
  • 5
    • 0019675004 scopus 로고
    • Detecting infiltration of water through soil cracks by timedomian reflectometry
    • Topp, G.C. and J.L. Davis. 1981. Detecting infiltration of water through soil cracks by timedomian reflectometry. Geoderma 26:13-23.
    • (1981) Geoderma , vol.26 , pp. 13-23
    • Topp, G.C.1    Davis, J.L.2
  • 6
    • 0022268802 scopus 로고
    • Measurement of soil water content using Time-Domain Reflectometry (TDR): A field evaluation
    • Topp, G.C. and J.L. Davis. 1985. Measurement of soil water content using Time-Domain Reflectometry (TDR): A field evaluation. Soil Sci. Soc. Amer. J. 49:19-24.
    • (1985) Soil Sci. Soc. Amer. J. , vol.49 , pp. 19-24
    • Topp, G.C.1    Davis, J.L.2
  • 7
    • 0018907660 scopus 로고
    • Electromagnetic determination of soil water content; measurement in coaxial transmission lines
    • Topp, G.C., J.L. Davis, and A.P. Annan. 1980. Electromagnetic determination of soil water content; measurement in coaxial transmission lines. Water Resour. Res. 16:574-582.
    • (1980) Water Resour. Res. , vol.16 , pp. 574-582
    • Topp, G.C.1    Davis, J.L.2    Annan, A.P.3
  • 8
    • 0020363269 scopus 로고
    • Electromagnetic determination of soil water content using TDR: II. Evaluation of installation and configuration of parallel transmission lines
    • Topp, G.C., J.L. Davis, and A.P. Annan. 1982. Electromagnetic determination of soil water content using TDR: II. Evaluation of installation and configuration of parallel transmission lines. Soil Sci. Soc. Amer. J. 46:678-684.
    • (1982) Soil Sci. Soc. Amer. J. , vol.46 , pp. 678-684
    • Topp, G.C.1    Davis, J.L.2    Annan, A.P.3
  • 9
    • 0026359696 scopus 로고
    • Field crop recovery and modeling of nitrogen mineralised from labeled sorghum residues
    • Vigil, M.F., D.E. Kissel, and S.J. Smith. 1991. Field crop recovery and modeling of nitrogen mineralised from labeled sorghum residues. Soil Sci. Soc. Amer. J. 55:1031-1037.
    • (1991) Soil Sci. Soc. Amer. J. , vol.55 , pp. 1031-1037
    • Vigil, M.F.1    Kissel, D.E.2    Smith, S.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.