메뉴 건너뛰기




Volumn 2, Issue 4, 1996, Pages 173-176

High-frequency conductance measurement of the skin surface hydration state of dry skin using a new probe studded with needle-form electrodes (MT-8C)

Author keywords

Capacitance; Dry skin; High frequency conductance; Probe; Skin surface hydration state; Stratum corneum

Indexed keywords

ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; CONDUCTANCE; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DRY SKIN; ELECTRODE; HUMAN; HYDRATION; MEASUREMENT; PSORIASIS; SKIN SURFACE; XEROSIS;

EID: 0030459937     PISSN: 0909752X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0846.1996.tb00146.x     Document Type: Article
Times cited : (6)

References (6)
  • 2
    • 0001772384 scopus 로고
    • Impedance measurement for evaluation of the hydration state of the skin surface
    • Leveque JL, eds. New York: Marcel Decker
    • Tagami H. Impedance measurement for evaluation of the hydration state of the skin surface. In: Leveque JL, eds. Cutaneous investigation in health and disease. New York: Marcel Decker, 1989: 79-111.
    • (1989) Cutaneous Investigation in Health and Disease , pp. 79-111
    • Tagami, H.1
  • 3
    • 0001561051 scopus 로고
    • Relevance, comparison, and validation of techniques
    • Serup J, Jemec GBE eds.: Boca Raton, FL, USA: CRC Press, Inc.
    • Pierard GE. Relevance, comparison, and validation of techniques. In: Serup J, Jemec GBE (eds.: Handbook of non-invasive methods and the skin. Boca Raton, FL, USA: CRC Press, Inc., 1995: 9-14.
    • (1995) Handbook of Non-invasive Methods and the Skin , pp. 9-14
    • Pierard, G.E.1
  • 4
    • 0021509557 scopus 로고
    • Trial for the development of special electrodes for the in vivo measurement of hydration state of stratum corneum of dry skin lesions
    • Tokudome Y, Tagami H. Trial for the development of special electrodes for the in vivo measurement of hydration state of stratum corneum of dry skin lesions. Jpn J Dermatol 1984: 94: 1247-1251.
    • (1984) Jpn J Dermatol , vol.94 , pp. 1247-1251
    • Tokudome, Y.1    Tagami, H.2
  • 6
    • 0027442595 scopus 로고
    • Electrical measurement of water content of the stratum corneum in vivo and in vitro under various conditions: Comparison between skin surface hygrometer and corneometer in evaluation of the skin surface hydration state
    • Hashimoto-Kumasaka K, Takahashi K, Tagami H. Electrical measurement of water content of the stratum corneum in vivo and in vitro under various conditions: comparison between skin surface hygrometer and corneometer in evaluation of the skin surface hydration state. Acta Derm Venerol 1993: 73: 335-339.
    • (1993) Acta Derm Venerol , vol.73 , pp. 335-339
    • Hashimoto-Kumasaka, K.1    Takahashi, K.2    Tagami, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.