메뉴 건너뛰기




Volumn 3, Issue 6 PART I, 1996, Pages 483-493

Quantitative comparison of single-isotope and dual-isotope stress-rest single-photon emission computed tomographic imaging for reversibility of defects

Author keywords

Dual isotope; Myocardial perfusion imaging; Quantification; Rest; Sestamibi; Single photon emission computed tomography; Stress; Thallium 201

Indexed keywords

METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M; THALLIUM 201;

EID: 0030454176     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1016/s1071-3581(96)90058-6     Document Type: Article
Times cited : (14)

References (26)
  • 1
    • 0024582126 scopus 로고
    • Technetium-99m hexakis 2-methoxyisobutyl isonitrile: Human biodistribution, dosimetry, safety, and preliminary comparison to thallium or myocardial perfusion imaging
    • Wackers FJTh, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, et al. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium or myocardial perfusion imaging. J Nucl Med 1989;30:301-11.
    • (1989) J Nucl Med , vol.30 , pp. 301-311
    • Wackers, F.J.Th.1    Berman, D.S.2    Maddahi, J.3    Watson, D.D.4    Beller, G.A.5    Strauss, H.W.6
  • 2
    • 0024577121 scopus 로고
    • Comparison of technetium 99m methoxyisobutyl isonitrile and thallium for evaluation of coronary artery disease by planar and tomographic methods
    • Kiat H, Maddahi J, Roy LT, et al. Comparison of technetium 99m methoxyisobutyl isonitrile and thallium for evaluation of coronary artery disease by planar and tomographic methods. Am Heart J 1989;117:1-11.
    • (1989) Am Heart J , vol.117 , pp. 1-11
    • Kiat, H.1    Maddahi, J.2    Roy, L.T.3
  • 3
    • 0024333498 scopus 로고
    • Clinical comparison between thallium and Tc-99m-methoxyisobutyl isonitrile (hexamibi) myocardial perfusion imaging for the detection of coronary artery disease
    • Taillefer R, Lambert R, Dupras G, et al. Clinical comparison between thallium and Tc-99m-methoxyisobutyl isonitrile (hexamibi) myocardial perfusion imaging for the detection of coronary artery disease. Eur J Nucl Med 1989;15:280-6.
    • (1989) Eur J Nucl Med , vol.15 , pp. 280-286
    • Taillefer, R.1    Lambert, R.2    Dupras, G.3
  • 4
    • 0024401961 scopus 로고
    • 99mTc 2-methoxy-isobutyl-isonitrile: A direct comparison in normal individuals and patients with coronary artery disease
    • 99mTc 2-methoxy-isobutyl-isonitrile: a direct comparison in normal individuals and patients with coronary artery disease. Circulation 1989;79:1282-93.
    • (1989) Circulation , vol.79 , pp. 1282-1293
    • Kahn, J.K.1    McGhie, I.2    Akers, M.S.3
  • 5
    • 0024321383 scopus 로고
    • Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium SPECT imaging
    • Iskandrian AS, Heo JO, Kong B, Lyons E, Marsch S. Use of technetium-99m isonitrile (RP-30A) in assessing left ventricular perfusion and function at rest and during exercise in coronary artery disease, and comparison with coronary arteriography and exercise thallium SPECT imaging. Am J Cardiol 1989;64:270-5.
    • (1989) Am J Cardiol , vol.64 , pp. 270-275
    • Iskandrian, A.S.1    Heo, J.O.2    Kong, B.3    Lyons, E.4    Marsch, S.5
  • 6
    • 0028032542 scopus 로고
    • The maze of myocardial perfusion imaging protocols in 1994
    • Wackers FJTh. The maze of myocardial perfusion imaging protocols in 1994. J Nucl Cardiol 1994;l:180-8.
    • (1994) J Nucl Cardiol , vol.50 , pp. 180-188
    • Wackers, F.J.Th.1
  • 7
    • 0027504581 scopus 로고
    • Separate acquisition rest thallium/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: A clinical validation study
    • Berman DS, Kiat H, Friedman JD, et al. Separate acquisition rest thallium/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study. J Am Coll Cardiol 1993;22:1455-64.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1455-1464
    • Berman, D.S.1    Kiat, H.2    Friedman, J.D.3
  • 8
    • 0028295782 scopus 로고
    • Sequential dual isotope SPECT imaging with thallium and technetium-99m-sestamibi
    • Heo J, Wolmer I, Kegel J, Iskandrian AS. Sequential dual isotope SPECT imaging with thallium and technetium-99m-sestamibi. J Nucl Med 1994;35:549-53.
    • (1994) J Nucl Med , vol.35 , pp. 549-553
    • Heo, J.1    Wolmer, I.2    Kegel, J.3    Iskandrian, A.S.4
  • 9
    • 0028218858 scopus 로고
    • Comparative feasibility of separate or simultaneous test thallium stress technetium-99m sestamibi dual isotope myocardial perfusion SPECT
    • Kiat H, Germano G, Friedman J, et al. Comparative feasibility of separate or simultaneous test thallium stress technetium-99m sestamibi dual isotope myocardial perfusion SPECT. J Nucl Med 1994;35:542-8.
    • (1994) J Nucl Med , vol.35 , pp. 542-548
    • Kiat, H.1    Germano, G.2    Friedman, J.3
  • 10
    • 0024467093 scopus 로고
    • Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium
    • Leppo JA, Meerdink DJ. Comparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium. Circ Res 1989;65:632-9.
    • (1989) Circ Res , vol.65 , pp. 632-639
    • Leppo, J.A.1    Meerdink, D.J.2
  • 11
    • 0024451338 scopus 로고
    • Comparison of hypoxia and ouabain effects on the myocardial uptake kinetics of technetium-99m hexakis 2-methoxyisobutyl isonitrile and thallium
    • Meerdink DJ, Leppo JA. Comparison of hypoxia and ouabain effects on the myocardial uptake kinetics of technetium-99m hexakis 2-methoxyisobutyl isonitrile and thallium. J Nucl Med 1989;30:1500-6.
    • (1989) J Nucl Med , vol.30 , pp. 1500-1506
    • Meerdink, D.J.1    Leppo, J.A.2
  • 12
    • 0027366693 scopus 로고
    • Myocardial risk area defined by technetium-99m sestamibi imaging during percutaneous transluminal coronary angioplasty: Comparison with coronary angiography
    • Haronian HL, Remetz MS, Sinusas AJ, et al. Myocardial risk area defined by technetium-99m sestamibi imaging during percutaneous transluminal coronary angioplasty: comparison with coronary angiography. J Am Coll Cardiol 1993;22:1033-43.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1033-1043
    • Haronian, H.L.1    Remetz, M.S.2    Sinusas, A.J.3
  • 13
    • 0028062085 scopus 로고
    • Science, art and artifacts: How important is quantification for the practicing physician interpreting myocardial perfusion studies
    • Wackers FJTh. Science, art and artifacts: how important is quantification for the practicing physician interpreting myocardial perfusion studies. J Nucl Cardiol 1994;1:S109-17.
    • (1994) J Nucl Cardiol , vol.1
    • Wackers, F.J.Th.1
  • 17
    • 0027493271 scopus 로고
    • Cardiac phantom evaluation of simultaneously acquired dualisotope rest thallium/stress technetium-99m SPECT images
    • Lowe VJ, Greer KL, Hanson MW, Jaszczak RJ, Coleman RE. Cardiac phantom evaluation of simultaneously acquired dualisotope rest thallium/stress technetium-99m SPECT images. J Nucl Med 1993;34:1998-2006.
    • (1993) J Nucl Med , vol.34 , pp. 1998-2006
    • Lowe, V.J.1    Greer, K.L.2    Hanson, M.W.3    Jaszczak, R.J.4    Coleman, R.E.5
  • 18
    • 21844448566 scopus 로고
    • Defect reversibility with dual isotope SPECT: Viability or just poorer contrast resolution with TI-201?
    • DePuey EG, Nichols K, Rozanski A, et al. Defect reversibility with dual isotope SPECT: viability or just poorer contrast resolution with TI-201? J Nucl Med 1994;35:103P.
    • (1994) J Nucl Med , vol.35
    • DePuey, E.G.1    Nichols, K.2    Rozanski, A.3
  • 19
    • 0028807603 scopus 로고
    • Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies
    • O'Connor MK, Caiati C, Christian TF, Gibbons RJ. Effects of scatter correction on the measurement of infarct size from SPECT cardiac phantom studies. J Nucl Med 1995;36:2080-6.
    • (1995) J Nucl Med , vol.36 , pp. 2080-2086
    • O'Connor, M.K.1    Caiati, C.2    Christian, T.F.3    Gibbons, R.J.4
  • 20
    • 0023851731 scopus 로고
    • Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile
    • Okada RD, Glover D, Gaffney T, Williams S. Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile. Circulation 1988;2:491-8.
    • (1988) Circulation , vol.2 , pp. 491-498
    • Okada, R.D.1    Glover, D.2    Gaffney, T.3    Williams, S.4
  • 21
    • 0025329833 scopus 로고
    • 99mTc-sestamibi in the presence of total coronary artery occlusion
    • 99mTc-sestamibi in the presence of total coronary artery occlusion. Am Heart J 1990;119:842-7.
    • (1990) Am Heart J , vol.119 , pp. 842-847
    • Mousa, S.A.1    Cooney, J.M.2    Williams, S.J.3
  • 22
    • 0026463155 scopus 로고
    • Comparison of technetium-99m sestamibi and thallium redistribution characteristics in canine myocardium
    • Melon PG, Beanlands RS, DeGrado TR, et al. Comparison of technetium-99m sestamibi and thallium redistribution characteristics in canine myocardium. J Am Coll Cardiol 1992;20:1277-83.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1277-1283
    • Melon, P.G.1    Beanlands, R.S.2    DeGrado, T.R.3
  • 23
    • 0025011908 scopus 로고
    • Uptake and retention of hexakis (2-methoxyisobutyl isonitrile) technetium (I) in cultured chick myocardial cells
    • Piwnica-Worms D, Kronauge JF, Chiu ML. Uptake and retention of hexakis (2-methoxyisobutyl isonitrile) technetium (I) in cultured chick myocardial cells. Circulation 1990;82:1826-38.
    • (1990) Circulation , vol.82 , pp. 1826-1838
    • Piwnica-Worms, D.1    Kronauge, J.F.2    Chiu, M.L.3
  • 24
    • 0027455483 scopus 로고
    • Effect of mitochondrial viability and metabolism of technetium-99m-sestamibi myocardial retention
    • Crane P, Laliberte R, Heminway S, et al. Effect of mitochondrial viability and metabolism of technetium-99m-sestamibi myocardial retention. Eur J Nucl Med 1993;20:20-5.
    • (1993) Eur J Nucl Med , vol.20 , pp. 20-25
    • Crane, P.1    Laliberte, R.2    Heminway, S.3
  • 25
    • 0025312889 scopus 로고
    • Myocardial redistribution of technetium-99m-methoxyisobutyl isonitrile (sestamibi)
    • Sheng Li Q, Solot G, Frank TL, Wagner HN, Becke LC. Myocardial redistribution of technetium-99m-methoxyisobutyl isonitrile (sestamibi). J Nucl Med 1990;31:1069-76.
    • (1990) J Nucl Med , vol.31 , pp. 1069-1076
    • Sheng Li, Q.1    Solot, G.2    Frank, T.L.3    Wagner, H.N.4    Becke, L.C.5
  • 26


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.