Volumn 6, Issue 2, 1996, Pages 117-124

The application and interpretation of intraclass correlations in the assessment of reliability in isokinetic dynamometry

Author keywords

Intraclass correlation coefficient (ICC); Isokinetics; Reliability; Review

Indexed keywords

CORRELATION FUNCTION; DYNAMOMETRY; ISOKINETIC EXERCISE; RELIABILITY; REVIEW;

EID: 0030453814     PISSN: 09593020     EISSN: None     Source Type: Journal    
DOI: 10.3233/ies-1996-6207     Document Type: Review
Times cited : (25)

References (22)
  • 1
    • 84974767746 scopus 로고
    • Reliability and limb symmetry for five unilateral functional tests of the lower extremity
    • Bandy WD, Rusche KR, Tekulve FY. Reliability and limb symmetry for five unilateral functional tests of the lower extremity. Isokinet Exerc Sci 1994;4:108-111.
    • (1994) Isokinet Exerc Sci , vol.4 , pp. 108-111
    • Bandy, W.D.1    Rusche, K.R.2    Tekulve, F.Y.3
  • 2
    • 0013941871 scopus 로고
    • Intraclass correlation coefficient as a measure of reliability
    • Bartko J. Intraclass correlation coefficient as a measure of reliability. Psycho Rep 1966;19:3-11.
    • (1966) Psycho Rep , vol.19 , pp. 3-11
    • Bartko, J.1
  • 4
    • 0024434317 scopus 로고
    • Intrasession reliability of angle specific knee extension torque measurements with gravity corrections
    • Bohannon R, Smith M. Intrasession reliability of angle specific knee extension torque measurements with gravity corrections. J Orth Sports Phys Ther 1989;11(4):155-157.
    • (1989) J Orth Sports Phys Ther , vol.11 , Issue.4 , pp. 155-157
    • Bohannon, R.1    Smith, M.2
  • 5
    • 84974750396 scopus 로고
    • Lateral trunk flexion strength measured by hand-held dynamometer
    • Bohannon, R. Lateral trunk flexion strength measured by hand-held dynamometer. Isokinet Exerc Sci 1994;4:30-33.
    • (1994) Isokinet Exerc Sci , vol.4 , pp. 30-33
    • Bohannon, R.1
  • 6
    • 84974750369 scopus 로고
    • Effect of Feldenkrais intervention on symptomatic subjects performing a functional reach
    • Chinn J, Trujillo D, Kegerreis S, Worrel T. Effect of Feldenkrais intervention on symptomatic subjects performing a functional reach. Isokinet Exerc Sci 1994;4:131-136.
    • (1994) Isokinet Exerc Sci , vol.4 , pp. 131-136
    • Chinn, J.1    Trujillo, D.2    Kegerreis, S.3    Worrel, T.4
  • 7
    • 0025999114 scopus 로고
    • Reliability of isokinetic measurements of trunk muscle performance
    • Delitto A, Rose S, Crandell C, Strube M. Reliability of isokinetic measurements of trunk muscle performance. Spine 1991;16(7):800-803.
    • (1991) Spine , vol.16 , Issue.7 , pp. 800-803
    • Delitto, A.1    Rose, S.2    Crandell, C.3    Strube, M.4
  • 9
    • 0025095507 scopus 로고
    • Test-retest reliability of the Biodex isokinetic dynamometer
    • Feiring D, Ellenbecker T, Derscheid G. Test-retest reliability of the Biodex isokinetic dynamometer. J Orth Sports Phys Ther 1990;11(7):298-300.
    • (1990) J Orth Sports Phys Ther , vol.11 , Issue.7 , pp. 298-300
    • Feiring, D.1    Ellenbecker, T.2    Derscheid, G.3
  • 10
    • 84974751518 scopus 로고
    • Endurance tests during isokinetic contraction: Reliability of functional parameters
    • Felicetti G, Zelaschi F, Patrizi S. Endurance tests during isokinetic contraction: reliability of functional parameters. Isokinet Exerc Sci 1994;4:76-80.
    • (1994) Isokinet Exerc Sci , vol.4 , pp. 76-80
    • Felicetti, G.1    Zelaschi, F.2    Patrizi, S.3
  • 12
    • 0022743647 scopus 로고
    • Computer communication: Reliability
    • Francis K. Computer communication: reliability. Phys Ther 1986;66:1140-1144.
    • (1986) Phys Ther , vol.66 , pp. 1140-1144
    • Francis, K.1
  • 14
    • 84974751535 scopus 로고
    • Comparison of quadriceps peak torque using three different dynamometers
    • Greenberger H, Wilkowksi T, Belyea B. Comparison of quadriceps peak torque using three different dynamometers. Isokinet Exerc Sci 1994;4:70-75.
    • (1994) Isokinet Exerc Sci , vol.4 , pp. 70-75
    • Greenberger, H.1    Wilkowksi, T.2    Belyea, B.3
  • 15
    • 84974744784 scopus 로고    scopus 로고
    • Reliability of the isoacceleration mode of the Lido active
    • 199
    • Grubbs N, Taggart I, Wyatt B. Reliability of the isoacceleration mode of the Lido active Isokinet Exerc Sci 199;4:13-18.
    • Isokinet Exerc Sci , vol.4 , pp. 13-18
    • Grubbs, N.1    Taggart, I.2    Wyatt, B.3
  • 16
    • 0346301595 scopus 로고    scopus 로고
    • Effect of protocol and assessment device on isokinetic peak torque of the quadriceps muscle group
    • 199
    • Heinrichs K, Perrin D, Weltman A, Gieck J, Ball D. Effect of protocol and assessment device on isokinetic peak torque of the quadriceps muscle group. Isokinet Exerc Sci 199;5:7-13.
    • Isokinet Exerc Sci , vol.5 , pp. 7-13
    • Heinrichs, K.1    Perrin, D.2    Weltman, A.3    Gieck, J.4    Ball, D.5
  • 17
    • 0002425011 scopus 로고
    • The mechanical and clinical reliability of the kinetic communicator's gravity correction procedure
    • Hellwig E, Perrin D. The mechanical and clinical reliability of the kinetic communicator's gravity correction procedure. Isokinet Exerc Sci 1995;5:85-91.
    • (1995) Isokinet Exerc Sci , vol.5 , pp. 85-91
    • Hellwig, E.1    Perrin, D.2
  • 18
    • 0028507512 scopus 로고
    • Clinical agreement in quantitative measurements
    • Indrayan A, Chawla R. Clinical agreement in quantitative measurements. Natl Med J India 1994;7(5):229-234.
    • (1994) Natl Med J India , vol.7 , Issue.5 , pp. 229-234
    • Indrayan, A.1    Chawla, R.2
  • 19
    • 84974776945 scopus 로고    scopus 로고
    • Effect of test protocol on torque production of the rotators of the shoulder
    • 199
    • Keskula D, Perrin D. Effect of test protocol on torque production of the rotators of the shoulder. Isokinet Exerc Sci 199;4:176-181.
    • Isokinet Exerc Sci , vol.4 , pp. 176-181
    • Keskula, D.1    Perrin, D.2
  • 20
    • 0000644772 scopus 로고
    • Computer communication: Intraclass correlation coefficients, uses and calculation
    • Krebs D. Computer communication: intraclass correlation coefficients, uses and calculation. Phys Ther 1984;64:1581-1583.
    • (1984) Phys Ther , vol.64 , pp. 1581-1583
    • Krebs, D.1
  • 21
    • 0000809142 scopus 로고
    • Intraclass correlations: There's more there than meets the eye
    • Lahey M, Downey R, Saal F. Intraclass correlations: there's more there than meets the eye. Psychol Bull 1983;93:586-595.
    • (1983) Psychol Bull , vol.93 , pp. 586-595
    • Lahey, M.1    Downey, R.2    Saal, F.3
  • 22
    • 0026744907 scopus 로고
    • Effect of instructions on isokinetic trunk strength testing variability, absolute value, and predictive validity
    • Matheson L, Mooney V, Caiozzo V, Jarvis G, Pottinger J, Debarry C, Backlund K, Klein K Antoni J. Effect of instructions on isokinetic trunk strength testing variability, absolute value, and predictive validity. Spine 1992;17(8):915-921.
    • (1992) Spine , vol.17 , Issue.8 , pp. 915-921
    • Matheson, L.1    Mooney, V.2    Caiozzo, V.3    Jarvis, G.4    Pottinger, J.5    Debarry, C.6    Backlund, K.7    Antoni J, K.K.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.