메뉴 건너뛰기




Volumn 19, Issue 12 I, 1996, Pages 2083-2088

Comparison of a unipolar defibrillation system with a dual lead system using an enlarged defibrillation anode

Author keywords

Defibrillation lead; Defibrillation threshold; Implantable cardioverter defibrillator

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOVERSION; CLINICAL ARTICLE; COMPARATIVE STUDY; DEFIBRILLATION; DEFIBRILLATOR; DEVICE; FEMALE; FLUOROSCOPY; HEART ARRHYTHMIA; HEART VENTRICLE FUNCTION; HUMAN; IMPEDANCE; IMPLANTATION; MALE; SUBCLAVIAN VEIN;

EID: 0030448529     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1996.tb03282.x     Document Type: Review
Times cited : (9)

References (6)
  • 1
    • 0027171761 scopus 로고
    • A simplified, single-lead unipolar transvenous cardioverter-defibrillator system
    • Bardy GH, Johnson G, Poole JE, et al. A simplified, single-lead unipolar transvenous cardioverter-defibrillator system. Circulation 1993; 88:543-547.
    • (1993) Circulation , vol.88 , pp. 543-547
    • Bardy, G.H.1    Johnson, G.2    Poole, J.E.3
  • 2
    • 0028197691 scopus 로고
    • Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode
    • Bardy GH, Dolack GL, Kudenchuk PJ, et al. Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode. Circulation 1994; 89:1090-1093.
    • (1994) Circulation , vol.89 , pp. 1090-1093
    • Bardy, G.H.1    Dolack, G.L.2    Kudenchuk, P.J.3
  • 3
    • 0028952889 scopus 로고
    • The left subclavian vein as an alternative site for implantation of the second defibrillation lead
    • Markewitz A, Kaulbach H, Mattke S, et al. The left subclavian vein as an alternative site for implantation of the second defibrillation lead. PACE 1995; 18:401-405.
    • (1995) PACE , vol.18 , pp. 401-405
    • Markewitz, A.1    Kaulbach, H.2    Mattke, S.3
  • 4
    • 0028897036 scopus 로고
    • Electrode surface area is an important variable for defibrillation
    • Singer I, Goldsmith J, Maldonado C. Electrode surface area is an important variable for defibrillation. PACE 1995; 18:233-236.
    • (1995) PACE , vol.18 , pp. 233-236
    • Singer, I.1    Goldsmith, J.2    Maldonado, C.3
  • 5
    • 0028919682 scopus 로고
    • Implantable cardioverter defibrillator lead technology: Improved performance and lower defibrillation thresholds
    • Lang DJ, Heil JE, Hahn SJ, et al. Implantable cardioverter defibrillator lead technology: improved performance and lower defibrillation thresholds. PACE 1995; 18:548-559.
    • (1995) PACE , vol.18 , pp. 548-559
    • Lang, D.J.1    Heil, J.E.2    Hahn, S.J.3
  • 6
    • 0026566151 scopus 로고
    • Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes
    • Tang ASL, Wolf PD, Afework Y, et al. Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes. Circulation 1992; 82: 1857-1864.
    • (1992) Circulation , vol.82 , pp. 1857-1864
    • Tang, A.S.L.1    Wolf, P.D.2    Afework, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.