Volumn 6, Issue 3-4, 1996, Pages 143-155

Cyclic fatigue of hydroxyapatite-coated titanium alloy implant material - Effect of crystallinity

Author keywords

crystallinity; cyclic fatigue; hydroxyapatite; stability; titanium alloy

Indexed keywords

CRYSTAL STRUCTURE; FATIGUE OF MATERIALS; FOURIER TRANSFORM INFRARED SPECTROSCOPY; MECHANICAL PROPERTIES; PHOSPHATE COATINGS; PLASMA SPRAYING; SPRAYED COATINGS; TITANIUM ALLOYS; X RAY DIFFRACTION ANALYSIS;

EID: 0030435801     PISSN: 10506934     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (27)
  • 1
    • 0026832935 scopus 로고
    • Tissue in-growth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Soballe, K., Hansen, E. S., Rasmussen, A. B., Jorgensen, P. H., and Bunger, C., Tissue in-growth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions, J. Orthop. Res., 1992: 10(2):285-299.
    • (1992) J. Orthop. Res. , vol.10 , Issue.2 , pp. 285-299
    • Soballe, K.1    Hansen, E.S.2    Rasmussen, A.B.3    Jorgensen, P.H.4    Bunger, C.5
  • 3
    • 0027605120 scopus 로고
    • Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants
    • Hayashi, K., Imadome, T., Mashima, T., and Sugioka, Y., Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants, J. Biomed. Mater. Res., 1993: 27:557-563.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 557-563
    • Hayashi, K.1    Imadome, T.2    Mashima, T.3    Sugioka, Y.4
  • 4
    • 0027604298 scopus 로고
    • Histologic investigation of the biologic behavior of different hydroxyapatite plasma-sprayed coatings in rabbits
    • Jansen, J. A., Van der Waerden, J. P. C. M., and Wolke, J. G. C., Histologic investigation of the biologic behavior of different hydroxyapatite plasma-sprayed coatings in rabbits, J. Biomed. Res., 1993: 27:603-610.
    • (1993) J. Biomed. Res. , vol.27 , pp. 603-610
    • Jansen, J.A.1    Van Der Waerden, J.P.C.M.2    Wolke, J.G.C.3
  • 5
    • 0026473503 scopus 로고
    • Retrospective analysis of hydroxyapatite development for oral implant applications
    • Jarcho, M., Retrospective analysis of hydroxyapatite development for oral implant applications, Dental Clinics No. Am., 1992: 36:19-26.
    • (1992) Dental Clinics No. Am. , vol.36 , pp. 19-26
    • Jarcho, M.1
  • 6
    • 0027897658 scopus 로고
    • Structure and integrity of a plasma sprayed hydroxyapatite coating on titanium
    • Whitehead, R. Y., Lacefield, W. R., and Lucas, L. C., Structure and integrity of a plasma sprayed hydroxyapatite coating on titanium, J. Biomed. Mater. Res., 1993: 27:1501-1507.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 1501-1507
    • Whitehead, R.Y.1    Lacefield, W.R.2    Lucas, L.C.3
  • 8
    • 0023676513 scopus 로고
    • Effect of porosity and physicochemical properties on the stability, resorption, and strength of calcium phosphate ceramics
    • de Groot, K., Effect of porosity and physicochemical properties on the stability, resorption, and strength of calcium phosphate ceramics, Ann. NY Acad. Sci., 1988: 523:227-233.
    • (1988) Ann. NY Acad. Sci. , vol.523 , pp. 227-233
    • De Groot, K.1
  • 10
    • 0025608937 scopus 로고
    • Hydroxyapatite-coated total hip prostheses: Two-year clinical and roentgenographic results of 100 cases
    • Geesink, R. G. T., Hydroxyapatite-coated total hip prostheses: Two-year clinical and roentgenographic results of 100 cases, Clin. Orthop. Related Res., 1990: 261:39-58.
    • (1990) Clin. Orthop. Related Res. , vol.261 , pp. 39-58
    • Geesink, R.G.T.1
  • 11
    • 0025453290 scopus 로고
    • Biointegrated hydroxyapatite-coated dental implants: 5 year clinical observations
    • Kent, J. N., Block, M. S., Finger, I. M., Guerra, L., Larsen, H., and Misick, D. J., Biointegrated hydroxyapatite-coated dental implants: 5 year clinical observations, JADA, 1990: 121:138-144.
    • (1990) JADA , vol.121 , pp. 138-144
    • Kent, J.N.1    Block, M.S.2    Finger, I.M.3    Guerra, L.4    Larsen, H.5    Misick, D.J.6
  • 12
    • 0027792526 scopus 로고
    • Cylindrical HA-coated implants - 8 year observations
    • Block, M. S. and Kent, J. N., Cylindrical HA-coated implants - 8 year observations, Compend. Contin., 1993: Supp 15:S526-S532.
    • (1993) Compend. Contin. , Issue.15 SUPPL.
    • Block, M.S.1    Kent, J.N.2
  • 13
    • 0027605128 scopus 로고
    • HA-coated root-form implants - Is there cause for concern?
    • James, R., HA-coated root-form implants - Is there cause for concern?, Dental Implantol. Update, 1993: 4(5):37-42.
    • (1993) Dental Implantol. Update , vol.4 , Issue.5 , pp. 37-42
    • James, R.1
  • 14
    • 0023674549 scopus 로고
    • Hydroxyapatite coatings
    • Lacefield, W. R., Hydroxyapatite coatings, Ann. NY Acad. Sci., 1988: 523:72-80.
    • (1988) Ann. NY Acad. Sci. , vol.523 , pp. 72-80
    • Lacefield, W.R.1
  • 15
    • 0026455928 scopus 로고
    • Calcium phosphate coatings for dental implants: Current status and future potential
    • Kay, J. F., Calcium phosphate coatings for dental implants: Current status and future potential, Dental Clinics No. Am., 1992: 36:1-18.
    • (1992) Dental Clinics No. Am. , vol.36 , pp. 1-18
    • Kay, J.F.1
  • 17
    • 0026353774 scopus 로고
    • Experimental coating defects in hydroxyapatite-coated implants
    • Cook, S. D., Thomas, K. A., and Kay, J. F., Experimental coating defects in hydroxyapatite-coated implants, Clin. Orthop., 1991: 265:280-290.
    • (1991) Clin. Orthop. , vol.265 , pp. 280-290
    • Cook, S.D.1    Thomas, K.A.2    Kay, J.F.3
  • 18
    • 8244220018 scopus 로고
    • X-ray diffraction characterization of percentage crystallinity and contaminants in plasma-sprayed hydroxylapatite coatings
    • ASTM STP 1196, Philadelphia: American Society for Testing and Materials
    • Prevey, P. S. and Rothwell, R. J., X-ray diffraction characterization of percentage crystallinity and contaminants in plasma-sprayed hydroxylapatite coatings, Characterization and Performance of Calcium Phosphate Coatings for Implants, ASTM STP 1196, Philadelphia: American Society for Testing and Materials, 1993.
    • (1993) Characterization and Performance of Calcium Phosphate Coatings for Implants
    • Prevey, P.S.1    Rothwell, R.J.2
  • 20
    • 0001415033 scopus 로고
    • Plasma sprayed calcium ceramic linings on porous metal coatings for bone ingrowth
    • Boca Raton, FL: CRC Press
    • Ducheyne, P., Cuckler, J., Radin, S. R., and Nazar, E., Plasma sprayed calcium ceramic linings on porous metal coatings for bone ingrowth, Handbook of Bioactive Ceramics III, Boca Raton, FL: CRC Press, 1990; 123-132.
    • (1990) Handbook of Bioactive Ceramics III , pp. 123-132
    • Ducheyne, P.1    Cuckler, J.2    Radin, S.R.3    Nazar, E.4
  • 21
    • 0027828798 scopus 로고
    • Maxilla vs. mandible - Why use HA?
    • Meffert, R. M., Maxilla vs. mandible - Why use HA?, Compend. Contin. Edu. Dent., 1993: Suppl 15:S533-S538.
    • (1993) Compend. Contin. Edu. Dent. , Issue.15 SUPPL.
    • Meffert, R.M.1
  • 22
    • 0000923692 scopus 로고
    • A scanning electron microscopy study of failed root from dental implant
    • Krauser, J. T., Bertholdt, P., Tammary, I., and Seckinger, R., A scanning electron microscopy study of failed root from dental implant, J. Dental Res., 1991: 65:274.
    • (1991) J. Dental Res. , vol.65 , pp. 274
    • Krauser, J.T.1    Bertholdt, P.2    Tammary, I.3    Seckinger, R.4
  • 23
    • 0026920955 scopus 로고
    • Stability of a cyclically loaded hydroxyapatite coating: Effect of substrate material, surface preparation, and testing environment
    • Kummer, F. J. and Jaffe, W. L., Stability of a cyclically loaded hydroxyapatite coating: Effect of substrate material, surface preparation, and testing environment, J. Appl. Biomater., 1992: 3:211-215.
    • (1992) J. Appl. Biomater. , vol.3 , pp. 211-215
    • Kummer, F.J.1    Jaffe, W.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.