메뉴 건너뛰기




Volumn 21, Issue 4, 1996, Pages 187-193

NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene A physicochemical and electrochemical characterization

Author keywords

Biocompatibility; Corrosion resistance; Nickel titanium; Radio frequency plasma; Shape memory alloy; Tetrafluoroethylene

Indexed keywords

BIOCOMPATIBILITY; CARBON; CORROSION RESISTANCE; NICKEL ALLOYS; OXYGEN; PLASMA SPRAYING; SHAPE MEMORY EFFECT; SURFACE PROPERTIES; SURFACE TREATMENT; TITANIUM DIOXIDE; X RAY PHOTOELECTRON SPECTROSCOPY;

EID: 0030428246     PISSN: 00476552     EISSN: None     Source Type: Journal    
DOI: 10.1023/a:1016985212314     Document Type: Article
Times cited : (7)

References (31)
  • 1
    • 36849132052 scopus 로고
    • Effect of low temperature phase on the mechanical properties of alloy near composition NiTi
    • Buehler WJ, Wang E. Effect of low temperature phase on the mechanical properties of alloy near composition NiTi. J Appl Phys 1963; 34: 1475.
    • (1963) J Appl Phys , vol.34 , pp. 1475
    • Buehler, W.J.1    Wang, E.2
  • 5
    • 33748204885 scopus 로고
    • Evaluation of Nitinol for use as a material in the construction of orthopaedic implants
    • Hughes JL. Evaluation of Nitinol for use as a material in the construction of orthopaedic implants. DAMD 17-74-C-4041, U S Army Medical Research and Development Command, Fort Detrick, Frederick, Md, 1977.
    • (1985) DAMD 17-74-C , pp. 1977
    • Hughes, J.L.1
  • 6
    • 0017015723 scopus 로고
    • Using the shape recovery of nitinol in the Harrington rod treatment of scoliosis
    • Schmerling MA, Wilkov MA, Sanders Ae, Woosley JE. Using the shape recovery of nitinol in the Harrington rod treatment of scoliosis. J Biomed Mater Res 1976; 10:879-892.
    • (1976) J Biomed Mater Res , vol.10 , pp. 879-892
    • Ma, S.1    Ma, W.2    Ae, S.3    Woosley, J.E.4
  • 7
    • 33748143650 scopus 로고
    • Surface corrosion of nitinol and stainless steel under clinical conditions
    • Edie Jw, Andreasen GF, Zaytoun MP. Surface corrosion of nitinol and stainless steel under clinical conditions. Orthodontics 1978;54:319-324.
    • (1978) Orthodontics , vol.54 , pp. 319-324
    • Edie, J.1    Andreasen, G.F.2    Zaytoun, M.P.3
  • 10
    • 84866219814 scopus 로고
    • Amélioration de la résistance àla corrosion de l'alliage àmémoire de forme nickel-titane par modification de surface
    • Lombard S. Amélioration de la résistance àla corrosion de l'alliage àmémoire de forme nickel-titane par modification de surface. Master thesis 1994, Université de Montréal.
    • (1994) Master Thesis
    • Lombard, S.1
  • 11
    • 0000359641 scopus 로고
    • Corrosion and biocompatibility of shape memory alloys
    • Oshida Y, Miyazaki S. Corrosion and biocompatibility of shape memory alloys. Corr Eng 1991; 40 : 1009-1025.
    • (1991) Corr Eng , vol.40 , pp. 1009-1025
    • Oshida, Y.1    Miyazaki, S.2
  • 15
    • 33748144533 scopus 로고
    • private communication.
    • Miyazaki S. 1994, private communication.
    • (1994)
    • Miyazaki, S.1
  • 20
    • 33748160849 scopus 로고
    • Plasma surface modification of NiTi shape memory alloys: An X-ray photoelectron spectroscopy study
    • Lombardi S, Yahia L'H, Selmani A, Rivard C-H. Plasma surface modification of NiTi shape memory alloys: An X-ray photoelectron spectroscopy study. Trans Soc Biomat 1994; vol. XVII: 174.
    • (1994) Trans Soc Biomat , pp. 174
    • Lombardi, S.1    Yahia, L.H.2    Selmani, A.3    Rivard, C.-H.4
  • 23
    • 0028726230 scopus 로고
    • Effect of plasma treatment on tribological properties of synthetic ligaments
    • Yahia L'H, Lombard S, Selmani A, Drouin G, Hlaouti M. Effect of plasma treatment on tribological properties of synthetic ligaments. Bio-Med Mater & Eng 1994; 4(5): 347-356
    • (1994) Bio-Med Mater & Eng , vol.4 , Issue.5 , pp. 347-356
    • Yahia, L.H.1    Lombard, S.2    Selmani, A.3    Drouin, G.4    Hlaouti, M.5
  • 24
    • 33748180024 scopus 로고
    • Methods for the preparation and pathological evaluation of bone implants
    • Broxup B. Methods for the preparation and pathological evaluation of bone implants. Trans Soc Biomat, 1994; vol. XVII: 400.
    • (1994) Trans Soc Biomat , vol.17 , pp. 400
    • Broxup, B.1
  • 25
    • 0025192709 scopus 로고
    • The corrosion behaviour of Nickel Titanium shape memory alloys
    • (8/9): 805-812.
    • Rondell G, Vicentini B, Cigada A. The corrosion behaviour of Nickel Titanium shape memory alloys. Corr Sei, 1990; 30 (8/9): 805-812.
    • (1990) Corr Sei , vol.30
    • Rondell, G.1    Vicentini, B.2    Cigada, A.3
  • 26
    • 0027961517 scopus 로고
    • Preliminary XPS spectroscopic characterization of autoclaved TiNi shape memory alloys for implants
    • Shabalovskaya SA, Anderegg JW, Sachdeva RLC, Harmon BN. Preliminary XPS spectroscopic characterization of autoclaved TiNi shape memory alloys for implants. Mat Res Soc Symp Proc, 1994; 331: 239-244.
    • (1994) Mat Res Soc Symp Proc , vol.331 , pp. 239-244
    • Shabalovskaya, S.A.1    Anderegg, J.W.2    Rlc, S.3    Harmon, B.N.4
  • 27
    • 84956038984 scopus 로고
    • Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants
    • Shabalovskaya SA, Anderegg JW. Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implants. J Vacuum Sei & Technol, 1995 (in press).
    • (1995) J Vacuum Sei & Technol
    • Shabalovskaya, S.A.1    Anderegg, J.W.2
  • 29
    • 0027677960 scopus 로고
    • Oxidation and diffusion processes in nickel-titanium oxide systems
    • Espinos JP, Fernandez A, Conzalez-EIipe AR. Oxidation and diffusion processes in nickel-titanium oxide systems. Surface Sei, 1993; 295: 402-410.
    • (1993) Surface Sei , vol.295 , pp. 402-410
    • Espinos, J.P.1    Fernandez, A.2    Conzalez, E.3
  • 31
    • 0028670785 scopus 로고
    • The challenge for hermetic encapsulation of implanted devices -A review
    • Nichols MF. The challenge for hermetic encapsulation of implanted devices -A review. C R in Biomed Eng, 1994; 22(1): 39-67.
    • (1994) C R in Biomed Eng , vol.22 , Issue.1 , pp. 39-67
    • Nichols, M.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.