메뉴 건너뛰기




Volumn 56, Issue 224, 1996, Pages 135-139

Electric potential measured, concentration reported: How to get mmols from mV

Author keywords

Activity and concentration; Electrolytes; Ion selective electrodes; Sensors

Indexed keywords

ELECTROLYTE;

EID: 0030338383     PISSN: 0085591X     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (11)

References (6)
  • 1
    • 0028142206 scopus 로고
    • Design and pitfalls of ion-selective electrodes
    • Lewenstam A. Design and pitfalls of ion-selective electrodes. Scand J Clin Lab Invest 1994;54, Suppl 217:11-9.
    • (1994) Scand J Clin Lab Invest , vol.54 , Issue.217 SUPPL. , pp. 11-19
    • Lewenstam, A.1
  • 2
    • 84942402928 scopus 로고
    • A. Approved recommendation (1984) on physico-chemical quantities and units in clinical chemistry
    • Siggaard-Andersen O, Durst R.A. Approved recommendation (1984) on physico-chemical quantities and units in clinical chemistry. J Clin Chem Clin Biochem. 1987;25:369-91.
    • (1987) J Clin Chem Clin Biochem , vol.25 , pp. 369-391
    • Siggaard-Andersen, O.1    Durst, R.2
  • 3
    • 0001305685 scopus 로고
    • Ion-selective electrodes in clinical chemistry. State of the art
    • Lewenstam A. Ion-selective electrodes in clinical chemistry. State of the art. Anal Proc 1991;28:106-9.
    • (1991) Anal Proc , vol.28 , pp. 106-109
    • Lewenstam, A.1
  • 4
    • 0027223088 scopus 로고
    • IFCC reference methods and materials for measurement of pH, gases and electrolytes in blood
    • Maas AHJ. IFCC reference methods and materials for measurement of pH, gases and electrolytes in blood. Scand J Clin Lab Invest 1993;53, Suppl 214:83-94.
    • (1993) Scand J Clin Lab Invest , vol.53 , Issue.214 SUPPL. , pp. 83-94
    • Maas, A.H.J.1
  • 5
    • 27044443621 scopus 로고
    • Adjusted active substance concentration and SI-system
    • Lewenstam A. Adjusted active substance concentration and SI-system. DG Klin Chem Mitteil 1993;24:301.
    • (1993) DG Klin Chem Mitteil , vol.24 , pp. 301
    • Lewenstam, A.1
  • 6
    • 27044434332 scopus 로고
    • Proposed recommendations on ion-selective electrode determinations of the substance concentration of sodium, potassium, and ionized calcium in serum, plasma, or whole blood
    • Tokyo: Excerpta Medica, Ltd
    • Maas AHJ. Proposed recommendations on ion-selective electrode determinations of the substance concentration of sodium, potassium, and ionized calcium in serum, plasma, or whole blood. In: The 6th International Symposium on Quality Control-Osaka. Tokyo: Excerpta Medica, Ltd, 1988:39-60.
    • (1988) The 6th International Symposium on Quality Control-Osaka , pp. 39-60
    • Maas, A.H.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.