메뉴 건너뛰기




Volumn 27, Issue SUPPL.3, 1996, Pages

Infection after open reduction and internal fixation with dynamic compression plates - Clinical and experimental data

Author keywords

Animal model; Clinical study; DCP; Fracture treatment; Infection rates; Metal implants

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 0030338325     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/0020-1383(96)89029-2     Document Type: Article
Times cited : (45)

References (29)
  • 1
    • 0025203230 scopus 로고
    • Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system
    • Matter P, Burch HB. Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system. Arch. Orthop. Trauma Surg. 1994;109:311-8.
    • (1994) Arch. Orthop. Trauma Surg. , vol.109 , pp. 311-318
    • Matter, P.1    Burch, H.B.2
  • 2
    • 0024517307 scopus 로고
    • Plates versus external fixation in severe open tibial fractures
    • Bach AW, Hansen ST. Plates versus external fixation in severe open tibial fractures. Clin. Orthop. 1989;241: 89-94.
    • (1989) Clin. Orthop. , vol.241 , pp. 89-94
    • Bach, A.W.1    Hansen, S.T.2
  • 4
    • 0000198499 scopus 로고
    • The role of surgical trauma in the aetiology of postoperative wound infections - Quantification of surgery-induced trauma
    • Siebert CH, Arens St, Hansis M. The role of surgical trauma in the aetiology of postoperative wound infections - Quantification of surgery-induced trauma. Hyg. Med. 1995;20:474-480.
    • (1995) Hyg. Med. , vol.20 , pp. 474-480
    • Siebert, C.H.1    Arens, St.2    Hansis, M.3
  • 5
    • 10644282115 scopus 로고    scopus 로고
    • Infektionsraten in der Unfallchirurgie - Eine Übersicht anhand der neueren deutschsprachigen Literatur
    • in press
    • Hansis M, Arens St, Wingenfeld C. Infektionsraten in der Unfallchirurgie - Eine Übersicht anhand der neueren deutschsprachigen Literatur. Aktuelle Traumatol. 1996, in press.
    • (1996) Aktuelle Traumatol.
    • Hansis, M.1    Arens, St.2    Wingenfeld, C.3
  • 6
    • 0013620724 scopus 로고
    • Evaluation of tissue compatibility of in vitro cultures of embryonic bone
    • Winter GD et al., eds. Chichester, New York, Brisbane, Toronto, Singapore: John Wiley & Sons Ltd.
    • Gerber H, Perren SM. Evaluation of tissue compatibility of in vitro cultures of embryonic bone. In: Winter GD et al., eds. Evaluation of Biomaterials. Chichester, New York, Brisbane, Toronto, Singapore: John Wiley & Sons Ltd., 1980.
    • (1980) Evaluation of Biomaterials
    • Gerber, H.1    Perren, S.M.2
  • 7
    • 0001976344 scopus 로고
    • The biocompatibility of certain stainless steel
    • Williams D, ed. Boca Raton, Florida: CRC-Press
    • Sutow EW, Pollak SR. The biocompatibility of certain stainless steel. In: Williams D, ed. Biocompatibility of Clinical Implant Materials. Boca Raton, Florida: CRC-Press, 1981:45-98.
    • (1981) Biocompatibility of Clinical Implant Materials , pp. 45-98
    • Sutow, E.W.1    Pollak, S.R.2
  • 8
    • 0005059996 scopus 로고
    • Titanium and titanium alloys
    • Williams D, ed. Boca Raton, Florida: CRC-Press
    • Williams D. Titanium and titanium alloys. In: Williams D, ed. Biocompatibility of Clinical Implant Materials. Boca Raton, Florida: CRC-Press, 1981:9-44.
    • (1981) Biocompatibility of Clinical Implant Materials , pp. 9-44
    • Williams, D.1
  • 9
    • 0022342163 scopus 로고
    • The influence of skeletal implants on incidence of infection. Experiments in a canine model
    • Petty W, Spanier S, Shuster JJ, Silverthorne C. The influence of skeletal implants on incidence of infection. Experiments in a canine model. J. Bone Joint Surg. [Am] 1985;67-A:1236-1244.
    • (1985) J. Bone Joint Surg. [Am] , vol.67 A , pp. 1236-1244
    • Petty, W.1    Spanier, S.2    Shuster, J.J.3    Silverthorne, C.4
  • 10
    • 0038541372 scopus 로고
    • The tissue response to implants and its evaluation by light microscopy
    • von Recum AF ed. London, UK: Collier Macmillan Publishers
    • Woodward SC, Salthouse TN. The tissue response to implants and its evaluation by light microscopy. In: von Recum AF ed. Handbook of biomaterial evaluation. London, UK: Collier Macmillan Publishers: 1986:364-378.
    • (1986) Handbook of Biomaterial Evaluation , pp. 364-378
    • Woodward, S.C.1    Salthouse, T.N.2
  • 11
    • 0023277742 scopus 로고
    • Biomaterial-centered infection: Microbial adhesion versus tissue integration
    • Gristina AG. Biomaterial-centered infection: microbial adhesion versus tissue integration. Science 1987; 237:1588-95.
    • (1987) Science , vol.237 , pp. 1588-1595
    • Gristina, A.G.1
  • 12
    • 0000766469 scopus 로고
    • Titanium alloys for surgical implants - Biocompatibility from physicochemical principles
    • Cannes
    • Steinemann SG, Mäusli PA. Titanium alloys for surgical implants - Biocompatibility from physicochemical principles. Sixth World Conference on Titanium, Cannes, 1988.
    • (1988) Sixth World Conference on Titanium
    • Steinemann, S.G.1    Mäusli, P.A.2
  • 14
    • 0002492140 scopus 로고
    • Das Konzept der biologischen Osteosynthese unter Anwendung der Dynamischen Kompressions-platte mit limitiertem Kontakt (LC-DCP)
    • Perren SM. Das Konzept der biologischen Osteosynthese unter Anwendung der Dynamischen Kompressions-platte mit limitiertem Kontakt (LC-DCP). Injury 1991; 22 (Suppl. 1):1-41.
    • (1991) Injury , vol.22 , Issue.1 SUPPL. , pp. 1-41
    • Perren, S.M.1
  • 15
    • 0026783940 scopus 로고
    • The effect of stainless steel, cobalt-chromium, titanium alloy, and titanium on the respiratory burst activity of human polymorphonuclear leucocytes
    • Pascual A, Tsukayama DT, Wicklund BH, Bechtold JE, Merritt K, Peterson PK, Gustilo RB. The effect of stainless steel, cobalt-chromium, titanium alloy, and titanium on the respiratory burst activity of human polymorphonuclear leucocytes. Clin. Orth. 1992; 280:281-8.
    • (1992) Clin. Orth. , vol.280 , pp. 281-288
    • Pascual, A.1    Tsukayama, D.T.2    Wicklund, B.H.3    Bechtold, J.E.4    Merritt, K.5    Peterson, P.K.6    Gustilo, R.B.7
  • 17
    • 0028808678 scopus 로고
    • Point Contact Fixator: Part I. Scientific Background, Design and Application
    • Perren SM, ed. Point Contact Fixator: Part I. Scientific Background, Design and Application. Injury 1995;26 (Suppl. 2):1-56.
    • (1995) Injury , vol.26 , Issue.2 SUPPL. , pp. 1-56
    • Perren, S.M.1
  • 19
    • 0003067565 scopus 로고
    • Clinical aspects of "bio-logical" plating
    • Ganz R, Mast J, Weber BG, Perren SM. Clinical aspects of "bio-logical" plating. Injury 1991;22 (Suppl. 1):4-5.
    • (1991) Injury , vol.22 , Issue.1 SUPPL. , pp. 4-5
    • Ganz, R.1    Mast, J.2    Weber, B.G.3    Perren, S.M.4
  • 20
    • 0242392854 scopus 로고
    • Die Bedeutung des Wirtsschadens bei der Entstehung postoperativer Wundinfektionen
    • Arens St, Hansis M, Siebert, C. Die Bedeutung des Wirtsschadens bei der Entstehung postoperativer Wundinfektionen. Hyg. Med. 1994;19:85-90.
    • (1994) Hyg. Med. , vol.19 , pp. 85-90
    • Arens, St.1    Hansis, M.2    Siebert, C.3
  • 22
    • 0021179721 scopus 로고
    • Pacemaker contact sensitivity
    • Peters MS et al. Pacemaker contact sensitivity. Contact dermatitis 1988;11:214-9.
    • (1988) Contact Dermatitis , vol.11 , pp. 214-219
    • Peters, M.S.1
  • 23
    • 0006941157 scopus 로고
    • Versuch einer Bewertung ("Scoring") posttraumatischer bzw. postoperativer Infektionen an Knochen und Weichteilen
    • Kienzle et al. ed. Hefte zu "Der Unfallchirurg"
    • Hansis M, Siebert CH, Arens St. Versuch einer Bewertung ("Scoring") posttraumatischer bzw. postoperativer Infektionen an Knochen und Weichteilen. In: Kienzle et al. ed. Diagnostik und Therapie der posttraumatischen Osteitis. Hefte zu "Der Unfallchirurg" 1995;255:249-254.
    • (1995) Diagnostik und Therapie der Posttraumatischen Osteitis , vol.255 , pp. 249-254
    • Hansis, M.1    Siebert, C.H.2    Arens, St.3
  • 25
    • 0029980240 scopus 로고    scopus 로고
    • Influence of the materials for fixation implants on local infection. An experimental study of steel versus titanium DC-Plates in rabbits
    • Arens St, Schlegel U, Printzen G, Ziegler WJ, Perren SM, Hansis M. Influence of the materials for fixation implants on local infection. An experimental study of steel versus titanium DC-Plates in rabbits. J. Bone Joint Surg. [Br] 1996;78-B:647-51.
    • (1996) J. Bone Joint Surg. [Br] , vol.78 B , pp. 647-651
    • Arens, St.1    Schlegel, U.2    Printzen, G.3    Ziegler, W.J.4    Perren, S.M.5    Hansis, M.6
  • 27
    • 2242463795 scopus 로고
    • Lokales Trauma als Katalysator für Infektion und Sepsis
    • Engelmann L, Kornhuber B, Rommelsheim K, Vogt S, eds.
    • Arens St, Siebert CH, Hansis M. Lokales Trauma als Katalysator für Infektion und Sepsis. In: Engelmann L, Kornhuber B, Rommelsheim K, Vogt S, eds. Endotoxin, Infektion, Sepsis. Update: Clinical Immunology 1995;4:141-152.
    • (1995) Endotoxin, Infektion, Sepsis. Update: Clinical Immunology , vol.4 , pp. 141-152
    • Arens, St.1    Siebert, C.H.2    Hansis, M.3
  • 28


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.