메뉴 건너뛰기




Volumn 210, Issue 4, 1996, Pages 301-302

Finite Element Analysis of a Total Knee Replacement by Using Gauss Point Contact Constraints

Author keywords

[No Author keywords available]

Indexed keywords

BIOMATERIAL; POLYETHYLENE DERIVATIVE; POLYPROPYLENE;

EID: 0030337775     PISSN: 09544119     EISSN: 20416518     Source Type: Journal    
DOI: 10.1243/PIME_PROC_1996_210_427_02     Document Type: Article
Times cited : (1)

References (9)
  • 1
    • 0029197651 scopus 로고
    • Contact pressure prediction in total knee joint replacements.Part 1: General elasticity solution for elliptical layeredcontacts
    • Jin Z. M. Dowson D. Fisher J. Contact pressure prediction in total knee joint replacements.Part 1: General elasticity solution for elliptical layeredcontacts. Proc. Instn Mech. Engrs, Part H, 1995, 209 (H 1),1–8.
    • (1995) Proc. Instn Mech. Engrs, Part H , vol.209 , Issue.1 , pp. 1-8
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3
  • 2
    • 0022107624 scopus 로고
    • The effect of conformity and plastic thickness on contactstresses in metal-backed plastic implants
    • Bartel D.L. Burstein A. H. Toda M. D. Edwards D.L. The effect of conformity and plastic thickness on contactstresses in metal-backed plastic implants. J.Biomech. Engng, 1985, 107, 193–199.
    • (1985) J.Biomech. Engng , vol.107 , pp. 193-199
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 3
    • 84990335932 scopus 로고
    • A theoretical and photoelastic contact stress analysis relevantto the plastic tibial plateau in an orthopaedic kneeprosthesis
    • Whelan M.P. Little E.G. A theoretical and photoelastic contact stress analysis relevantto the plastic tibial plateau in an orthopaedic kneeprosthesis. Proceedings of the CMBEC/CCGBConference, Banff, Canada, 1991.
    • (1991) Proceedings of the CMBEC/CCGBConference, Banff, Canada
    • Whelan, M.P.1    Little, E.G.2
  • 4
    • 84981642591 scopus 로고
    • A theoretical and photoelastic contact stress analysis relevantto orthopaedic knee prosthesis
    • Whelan M.P. Little E.G. A theoretical and photoelastic contact stress analysis relevantto orthopaedic knee prosthesis. Strain, 1992, 28(2),61–69.
    • (1992) Strain , vol.28 , Issue.2 , pp. 61-69
    • Whelan, M.P.1    Little, E.G.2
  • 7
    • 84990341249 scopus 로고
    • Contact stress analysis relevant to orthopaedic knee prosthesesusing a combination of experimental, theoretical and finite elementtechniques
    • Whelan M.P. Contact stress analysis relevant to orthopaedic knee prosthesesusing a combination of experimental, theoretical and finite elementtechniques. Proceedings (student) of 50thAnniversary ASME Conference, Detroit, 1993.
    • (1993) Proceedings (student) of 50thAnniversary ASME Conference, Detroit
    • Whelan, M.P.1
  • 8
    • 0029346755 scopus 로고
    • Modelling an orthopaedic knee prosthesis as a layered elasticsystem—Part 1: Experimental and theoretical analyses
    • Whelan M.P. O'Donnell P. Little E.G. Modelling an orthopaedic knee prosthesis as a layered elasticsystem—Part 1: Experimental and theoretical analyses. J. Strain Analysis, 1995, 30(3), 185.
    • (1995) J. Strain Analysis , vol.30 , Issue.3 , pp. 185
    • Whelan, M.P.1    O'Donnell, P.2    Little, E.G.3
  • 9
    • 0029342728 scopus 로고
    • Modelling an orthopaedic knee prosthesis as a layered elasticsystem—Part II: Finite element analysis
    • Whelan M.P. Mottershead J. E. Edwards P. D. Little E.G. Modelling an orthopaedic knee prosthesis as a layered elasticsystem—Part II: Finite element analysis. J.Strain Analysis, 1995, 30(3), 195.
    • (1995) J.Strain Analysis , vol.30 , Issue.3 , pp. 195
    • Whelan, M.P.1    Mottershead, J.E.2    Edwards, P.D.3    Little, E.G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.