메뉴 건너뛰기




Volumn 6, Issue 6, 1996, Pages 429-439

Reinforcement of PMMA bone cement with a continuous wire coil - a 3D finite element study

Author keywords

Bone cement; Finite element model; Fixation; Hoop stress; Radial stress; Stainless steel wire reinforcement

Indexed keywords

BONE CEMENT; METHACRYLIC ACID METHYL ESTER; STAINLESS STEEL;

EID: 0030334833     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: 10.3233/bme-1996-6604     Document Type: Article
Times cited : (4)

References (31)
  • 1
    • 0026527960 scopus 로고
    • Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty
    • R.L. Barrack, R.D. Mulroy and W.H. Harris, Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty, Journal of Bone and Joint Surgery 74B (1992), 385-389.
    • (1992) Journal of Bone and Joint Surgery , vol.74 B , pp. 385-389
    • Barrack, R.L.1    Mulroy, R.D.2    Harris, W.H.3
  • 2
    • 0025728112 scopus 로고
    • Long term (twelve to eighteen-year) follow-up of cemented total hip replacements in patients who were less than fifty years old: A follow-up note
    • D.K. Collis, Long term (twelve to eighteen-year) follow-up of cemented total hip replacements in patients who were less than fifty years old: a follow-up note, Journal of Bone and Joint Surgery 73A (1991), 593-597.
    • (1991) Journal of Bone and Joint Surgery , vol.73 A , pp. 593-597
    • Collis, D.K.1
  • 3
    • 0027432581 scopus 로고
    • Cemented versus cemented total hip arthroplasty - A scientific controversy?
    • B.M. Wroblewiski, Cemented versus cemented total hip arthroplasty - a scientific controversy?, Orthopaedic Clinics of North America 24 (1993), 591-597.
    • (1993) Orthopaedic Clinics of North America , vol.24 , pp. 591-597
    • Wroblewiski, B.M.1
  • 4
    • 0028108743 scopus 로고
    • The results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old - A ten year follow-up study
    • W.T. Ballard, J.J. Callaghan, P.M. Sullivan and R.C. Johnston, The results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old - a ten year follow-up study, The Journal of Bone and Joint Surgery 76A (1994), 959-964.
    • (1994) The Journal of Bone and Joint Surgery , vol.76 A , pp. 959-964
    • Ballard, W.T.1    Callaghan, J.J.2    Sullivan, P.M.3    Johnston, R.C.4
  • 6
    • 1842471077 scopus 로고
    • Third generation cementing of the femoral stem in total hip arthroplasty protects against femoral lysis
    • San Francisco, CA, February
    • D.D. Goetz, E.J. Smith and W.H. Harris, Third generation cementing of the femoral stem in total hip arthroplasty protects against femoral lysis, Presented at the AAOS Meeting, San Francisco, CA, February, 1993.
    • (1993) AAOS Meeting
    • Goetz, D.D.1    Smith, E.J.2    Harris, W.H.3
  • 7
    • 0025161599 scopus 로고
    • The effect of improved cementing techniques on component loosening in total hip replacement: An 11-year radiographic review
    • R.D.J. Mulroy and W.H. Harris, The effect of improved cementing techniques on component loosening in total hip replacement: an 11-year radiographic review, Journal of Bone and Joint Surgery 72B (1990), 757.
    • (1990) Journal of Bone and Joint Surgery , vol.72 B , pp. 757
    • Mulroy, R.D.J.1    Harris, W.H.2
  • 12
    • 0020541681 scopus 로고
    • Total hip arthroplasties in patients less than forty-five years old
    • L.D. Dorr, G.K. Takei and J.P. Conaty, Total hip arthroplasties in patients less than forty-five years old, Journal of Bone and Joint Surgery 65A (1983), 474-479.
    • (1983) Journal of Bone and Joint Surgery , vol.65 A , pp. 474-479
    • Dorr, L.D.1    Takei, G.K.2    Conaty, J.P.3
  • 13
    • 0018104415 scopus 로고
    • Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug
    • I. Oh, C.E. Carlson, W.W. Tomford and W.H. Harris, Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug, Journal of Bone and Joint Surgery 60A (1978), 608-613.
    • (1978) Journal of Bone and Joint Surgery , vol.60 A , pp. 608-613
    • Oh, I.1    Carlson, C.E.2    Tomford, W.W.3    Harris, W.H.4
  • 14
    • 1842418521 scopus 로고
    • Results of improved cement distribution
    • October
    • B.M. Wroblewski, Results of improved cement distribution, 20th Annual Hip Course, October 1990.
    • (1990) 20th Annual Hip Course
    • Wroblewski, B.M.1
  • 15
    • 0027375254 scopus 로고
    • Total hip replacement in the middle-aged patient - Contemporary cementing for fixation of the femoral component
    • W.H. Harris, Total hip replacement in the middle-aged patient - contemporary cementing for fixation of the femoral component, Orthopaedic Clinics of North America 24 (1993), 611-616.
    • (1993) Orthopaedic Clinics of North America , vol.24 , pp. 611-616
    • Harris, W.H.1
  • 16
    • 85118959437 scopus 로고
    • The various stress patterns of press-fit, ingrown and cemented femoral stems
    • R. Huiskes, The various stress patterns of press-fit, ingrown and cemented femoral stems, Clinical Orthopaedics and Related Research 27 (1990), 38.
    • (1990) Clinical Orthopaedics and Related Research , vol.27 , pp. 38
    • Huiskes, R.1
  • 17
    • 0027902464 scopus 로고
    • Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant
    • I.Y. Lee, H.B. Skinner and J.H. Keyak, Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant, Iowa Orthopaedic Journal 13 (1993), 155-159.
    • (1993) Iowa Orthopaedic Journal , vol.13 , pp. 155-159
    • Lee, I.Y.1    Skinner, H.B.2    Keyak, J.H.3
  • 18
    • 0028500672 scopus 로고
    • Effects of variation of prosthesis size on cement stress at the tip of a femoral implant
    • I.Y. Lee, H.B. Skinner and J.H. Keyak, Effects of variation of prosthesis size on cement stress at the tip of a femoral implant, Journal of Biomedical Materials Research 28 (1994), 1055-1060.
    • (1994) Journal of Biomedical Materials Research , vol.28 , pp. 1055-1060
    • Lee, I.Y.1    Skinner, H.B.2    Keyak, J.H.3
  • 19
    • 0343521109 scopus 로고
    • Mechanicl consequences of cement-metal interface disruption (debonding) at the distal tip of femoral total hip prosthesis
    • T.P. Harrigan and W.H. Harris, Mechanicl consequences of cement-metal interface disruption (debonding) at the distal tip of femoral total hip prosthesis, Transactions of the Orthopaedic Research Society 16 (1991), 503.
    • (1991) Transactions of the Orthopaedic Research Society , vol.16 , pp. 503
    • Harrigan, T.P.1    Harris, W.H.2
  • 21
    • 1842418526 scopus 로고
    • Mechanical characterization of commercially made carbon-fiber-reinforced polymethylmethacrylate
    • S. Saha and S. Pal, Mechanical characterization of commercially made carbon-fiber-reinforced polymethylmethacrylate, Journal of Biomedical Materials Research 17 (1986), 31-35.
    • (1986) Journal of Biomedical Materials Research , vol.17 , pp. 31-35
    • Saha, S.1    Pal, S.2
  • 23
  • 25
    • 0022909783 scopus 로고
    • Comparison of mechanical properties of discontinuous Kevlar® 29 fiber reinforced bone and dental cements
    • B. Pourdeyhimi, H.D. Wagner and P. Schwartz, Comparison of mechanical properties of discontinuous Kevlar® 29 fiber reinforced bone and dental cements, Journal of Material Science 221 (1986), 4468-4474.
    • (1986) Journal of Material Science , vol.221 , pp. 4468-4474
    • Pourdeyhimi, B.1    Wagner, H.D.2    Schwartz, P.3
  • 26
    • 0022899098 scopus 로고
    • Fracture toughness of Kevlar® 29 /poly(methyl methacrylate) composite materials for surgical implantation
    • B. Pourdeyhimi, H.H. Robinson IV, P. Schwartz and H.D. Wagner, Fracture toughness of Kevlar® 29 /poly(methyl methacrylate) composite materials for surgical implantation, Annals of Biomedical Engineering 14 (1986), 277-294.
    • (1986) Annals of Biomedical Engineering , vol.14 , pp. 277-294
    • Pourdeyhimi, B.1    Robinson IV, H.H.2    Schwartz, P.3    Wagner, H.D.4
  • 27
    • 0027962073 scopus 로고
    • A study of reinforcement selection for poly(methyl methacrylate) bone cement for surgical implantation
    • Y. Ulcay and B. Pourdeyhimi, A study of reinforcement selection for poly(methyl methacrylate) bone cement for surgical implantation, in: Integrated Design and Manufacturing of Composites ASME, 1994, pp. 193-202.
    • (1994) Integrated Design and Manufacturing of Composites ASME , pp. 193-202
    • Ulcay, Y.1    Pourdeyhimi, B.2
  • 28
    • 0028709898 scopus 로고
    • Reinforcement of bone cement around prosthesis by pre-coated wire coil: A preliminary study
    • J.K. Kim and J.B. Park, Reinforcement of bone cement around prosthesis by pre-coated wire coil: A preliminary study, Bio-Medical Materials and Engineering 4 (1994), 1-11.
    • (1994) Bio-Medical Materials and Engineering , vol.4 , pp. 1-11
    • Kim, J.K.1    Park, J.B.2
  • 30
    • 0017619864 scopus 로고
    • Tensile strength of wire reinforced bone cement and twisted stainless steel wire
    • J.P. Traitsman and S. Saha, Tensile strength of wire reinforced bone cement and twisted stainless steel wire, Journal of Bone and Joint Surgery 59A (1977), 419-425.
    • (1977) Journal of Bone and Joint Surgery , vol.59 A , pp. 419-425
    • Traitsman, J.P.1    Saha, S.2
  • 31
    • 0029182929 scopus 로고
    • Reinforcement of bone cement around prosthesis by pre-coated wire coil - A finite element model study
    • N. Grosland, J.K. Kim and J.B. Park, Reinforcement of bone cement around prosthesis by pre-coated wire coil - a finite element model study, Biomedical Materials and Engineering 5 (1995), 29-36.
    • (1995) Biomedical Materials and Engineering , vol.5 , pp. 29-36
    • Grosland, N.1    Kim, J.K.2    Park, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.