메뉴 건너뛰기




Volumn 16, Issue 6, 1996, Pages 520-527

An integrated system for measuring static and dynamic accommodation with a canon autoref R-1 refractometer

Author keywords

[No Author keywords available]

Indexed keywords

ACCOMMODATION; ARTICLE; COMPUTER PROGRAM; COMPUTER SYSTEM; EYE REFRACTION; HUMAN; MEASUREMENT; PRIORITY JOURNAL; REFRACTION INDEX;

EID: 0030298289     PISSN: 02755408     EISSN: None     Source Type: Journal    
DOI: 10.1016/0275-5408(96)00018-X     Document Type: Article
Times cited : (8)

References (7)
  • 1
    • 0022356835 scopus 로고
    • Clinical evaluation of the Canon Autoref R-1
    • McBrien, N. A. and Millodot, M. (1985). Clinical evaluation of the Canon Autoref R-1. Am. J. Optom. Physiol. Opt. 62, 786-792.
    • (1985) Am. J. Optom. Physiol. Opt. , vol.62 , pp. 786-792
    • McBrien, N.A.1    Millodot, M.2
  • 2
    • 0002236535 scopus 로고
    • The design of an open view autorefractometer
    • (eds G. M. Breinin and I. M. Siegel) Springer Series in Optical Sciences, Springer, Berlin, Germany
    • Matsumura, I., Maruyama, S., Ishikawa, Y., Hirano, R., Kobayashi, K. and Kohayakawa, Y. (1983). The design of an open view autorefractometer. In: Advances in Diagnostic Visual Optics (eds G. M. Breinin and I. M. Siegel) Springer Series in Optical Sciences, Springer, Berlin, Germany, pp. 36-42.
    • (1983) Advances in Diagnostic Visual Optics , pp. 36-42
    • Matsumura, I.1    Maruyama, S.2    Ishikawa, Y.3    Hirano, R.4    Kobayashi, K.5    Kohayakawa, Y.6
  • 3
    • 0027297832 scopus 로고
    • Calibration of the Canon Autoref R-1 for continuous measurement of accommodation
    • Davis, B., Collins, M. and Atchison, D. (1993). Calibration of the Canon Autoref R-1 for continuous measurement of accommodation. Ophthal. Physiol. Opt. 13, 191-198.
    • (1993) Ophthal. Physiol. Opt. , vol.13 , pp. 191-198
    • Davis, B.1    Collins, M.2    Atchison, D.3
  • 4
    • 0024263611 scopus 로고
    • Modification of the Canon Auto Ref R1 for use as a continuously recording infra-red optometer
    • Pugh, J. R. and Winn, B. (1988). Modification of the Canon Auto Ref R1 for use as a continuously recording infra-red optometer. Ophthal. Physiol. Opt. 8, 460-464.
    • (1988) Ophthal. Physiol. Opt. , vol.8 , pp. 460-464
    • Pugh, J.R.1    Winn, B.2
  • 5
    • 0024790742 scopus 로고
    • A procedural guide to the modification of a Canon AutoRef R-1 for use as a continuously recording optometer
    • Pugh, J. R. and Winn, B. (1989). A procedural guide to the modification of a Canon AutoRef R-1 for use as a continuously recording optometer. Ophthal. Physiol. Opt. 9, 451-454.
    • (1989) Ophthal. Physiol. Opt. , vol.9 , pp. 451-454
    • Pugh, J.R.1    Winn, B.2
  • 6
    • 0023132074 scopus 로고
    • The effect of stimulus contrast on the accommodative response
    • Ward, P. A. (1987). The effect of stimulus contrast on the accommodative response. Ophthal. Physiol. Opt. 7, 9-15.
    • (1987) Ophthal. Physiol. Opt. , vol.7 , pp. 9-15
    • Ward, P.A.1
  • 7
    • 0024379213 scopus 로고
    • The effect of pupil size on static and dynamic measurements of accommodation using an infrared optometer
    • Winn, B., Pugh, J. R., Gilmartin, B. and Owens, H. (1989). The effect of pupil size on static and dynamic measurements of accommodation using an infrared optometer. Ophthal. Physiol. Opt. 9, 277-283.
    • (1989) Ophthal. Physiol. Opt. , vol.9 , pp. 277-283
    • Winn, B.1    Pugh, J.R.2    Gilmartin, B.3    Owens, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.