Volumn 15, Issue 11, 1996, Pages 775-784

Spectral and color Doppler sonographic applications of a new test object with adjustable moving target spacing

Author keywords

Doppler ultrasonography; Quality assurance; Sensitivity; Spatial resolution; Velocity calibration

Indexed keywords

COLOR IMAGE PROCESSING; QUALITY ASSURANCE;

EID: 0030298132     PISSN: 02784297     EISSN: None     Source Type: Journal    
DOI: 10.7863/jum.1996.15.11.775     Document Type: Article
Times cited : (5)

References (17)
  • 3
    • 0020040859 scopus 로고
    • Evaluating Doppler devices using a moving string test object
    • Walker AJ, Philips DJ, Powers JE: Evaluating Doppler devices using a moving string test object. J Clin Ultrasound 10:25 1982
    • (1982) J Clin Ultrasound , vol.10 , pp. 25
    • Walker, A.J.1    Philips, D.J.2    Powers, J.E.3
  • 4
    • 0025108098 scopus 로고
    • Testing ultrasonic pulsed Doppler instruments with a physiologic phantom
    • Phillips DJ, Hossack J, Beach KW, et al: Testing ultrasonic pulsed Doppler instruments with a physiologic phantom. J Ultrasound Med 9:429, 1990
    • (1990) J Ultrasound Med , vol.9 , pp. 429
    • Phillips, D.J.1    Hossack, J.2    Beach, K.W.3
  • 5
    • 0026021204 scopus 로고
    • Performance tests of Doppler ultrasound equipment with a string phantom
    • Goldstein A: Performance tests of Doppler ultrasound equipment with a string phantom. J Ultrasound Med 10:125, 1991
    • (1991) J Ultrasound Med , vol.10 , pp. 125
    • Goldstein, A.1
  • 7
    • 85027231501 scopus 로고
    • The BBS string phantom
    • Hoskins PR, Sherriff SB, Evan JA (Eds): Report No. 70. York, UK, The Institute of Physical Sciences in Medicine
    • Hoskins PR: The BBS string phantom. In Hoskins PR, Sherriff SB, Evan JA (Eds): Testing of Doppler Ultrasound Equipment. Report No. 70. York, UK, The Institute of Physical Sciences in Medicine, 1994
    • (1994) Testing of Doppler Ultrasound Equipment
    • Hoskins, P.R.1
  • 9
    • 0028080263 scopus 로고
    • Choice of moving target for string phantom. I. Measurement of filament backscatter characteristics
    • Hoskins PR: Choice of moving target for string phantom. I. Measurement of filament backscatter characteristics. Ultrasound Med Biol 20:773, 1994
    • (1994) Ultrasound Med Biol , vol.20 , pp. 773
    • Hoskins, P.R.1
  • 10
    • 0027944417 scopus 로고
    • Choice of moving target for string phantom. II. on the performance testing of Doppler ultrasound systems
    • Hoskins PR: Choice of moving target for string phantom. II. On the performance testing of Doppler ultrasound systems. Ultrasound Med Biol 20:781, 1994
    • (1994) Ultrasound Med Biol , vol.20 , pp. 781
    • Hoskins, P.R.1
  • 11
    • 0029378406 scopus 로고
    • On the performance of regression and step-initialized IIR clutter filters for color Doppler systems in diagnostic medical ultrasound
    • Kadi AP, Loupas T: On the performance of regression and step-initialized IIR clutter filters for color Doppler systems in diagnostic medical ultrasound. IEEE Trans Ultrason Ferroelec Freq Control 42:927, 1995
    • (1995) IEEE Trans Ultrason Ferroelec Freq Control , vol.42 , pp. 927
    • Kadi, A.P.1    Loupas, T.2
  • 13
    • 0345313017 scopus 로고
    • Review of the design and use of string phantoms
    • Hoskins PR, Sherriff SB, Evan JA (Eds): Report No. 70. York, UK, The Institute of Physical Sciences in Medicine
    • Hoskins PR: Review of the design and use of string phantoms. In Hoskins PR, Sherriff SB, Evan JA (Eds): Testing of Doppler Ultrasound Equipment. Report No. 70. York, UK, The Institute of Physical Sciences in Medicine, 1994
    • (1994) Testing of Doppler Ultrasound Equipment
    • Hoskins, P.R.1
  • 15
    • 0000123717 scopus 로고
    • Overestimation of velocity and frequency values by multielement linear array Dopplers
    • Daigle RJ, Stavros AT, Lee RM: Overestimation of velocity and frequency values by multielement linear array Dopplers. J Vasc Technology 14:206, 1990
    • (1990) J Vasc Technology , vol.14 , pp. 206
    • Daigle, R.J.1    Stavros, A.T.2    Lee, R.M.3
  • 16
    • 0025125915 scopus 로고
    • Assurance of consistent peak-velocity measurements with a variety of duplex Doppler instruments
    • Kimme-Smith C, Hussain R, Duerinckx A, et al: Assurance of consistent peak-velocity measurements with a variety of duplex Doppler instruments. Radiology 177:265, 1990
    • (1990) Radiology , vol.177 , pp. 265
    • Kimme-Smith, C.1    Hussain, R.2    Duerinckx, A.3
  • 17
    • 0028963834 scopus 로고
    • Peak velocity overestimation and linear-array spectral Doppler
    • Eicke BM, Kremkau FW, Hinson H, et al: Peak velocity overestimation and linear-array spectral Doppler. J Neuroimaging 5:115, 1995
    • (1995) J Neuroimaging , vol.5 , pp. 115
    • Eicke, B.M.1    Kremkau, F.W.2    Hinson, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.