메뉴 건너뛰기




Volumn 37, Issue 1-2, 1996, Pages 97-102

Comparison of carbon paste electrodes modified with native and polyethylene glycol derivatized horseradish peroxidases for the amperometric monitoring of H2O2

Author keywords

Amperometry; Biosensors; Carbon paste; Horseradish peroxidase; Polyethylene glycol

Indexed keywords

BIOSENSORS; CARBON; CHARGE TRANSFER; ELECTROCHEMICAL ELECTRODES; ELECTROPHORESIS; HYDROGEN INORGANIC COMPOUNDS; HYDROGEN PEROXIDE; PH; POLYETHYLENE GLYCOLS;

EID: 0030291734     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(97)80076-7     Document Type: Article
Times cited : (4)

References (17)
  • 1
    • 84987492148 scopus 로고
    • Carbon paste electrodes modified with enzymes, tissues, and cells
    • L. Gorton, Carbon paste electrodes modified with enzymes, tissues, and cells, Electroanalysis, 7 (1995) 23-45.
    • (1995) Electroanalysis , vol.7 , pp. 23-45
    • Gorton, L.1
  • 2
    • 0001322444 scopus 로고
    • Long-term operational stability of a mixed glucose oxidase-redox mediator-carbon paste electrode
    • A. Amine, J.-M. Kauffmann and G.J. Patriarche, Long-term operational stability of a mixed glucose oxidase-redox mediator-carbon paste electrode, Anal. Lett., 24 (1991) 1293-1315.
    • (1991) Anal. Lett. , vol.24 , pp. 1293-1315
    • Amine, A.1    Kauffmann, J.-M.2    Patriarche, G.J.3
  • 3
    • 0000463767 scopus 로고
    • Glucose-sensing electrode based on carbon paste containing ferrocene and polyethylene glycol-modified enzyme
    • F. Mizutani, S. Yabuki, A. Okuda, and T. Katsura, Glucose-sensing electrode based on carbon paste containing ferrocene and polyethylene glycol-modified enzyme, Bull. Chem. Soc. Jpn., 64 (1991) 2849-2851.
    • (1991) Bull. Chem. Soc. Jpn. , vol.64 , pp. 2849-2851
    • Mizutani, F.1    Yabuki, S.2    Okuda, A.3    Katsura, T.4
  • 4
    • 0027087476 scopus 로고
    • Glucose-sensing carbon paste electrode containing polyethylene glycol-modified glucose oxidase
    • S. Yabuki, F. Mizutani and T. Katsura, Glucose-sensing carbon paste electrode containing polyethylene glycol-modified glucose oxidase, Biosensors Bioelectron., 7 (1992) 695-700.
    • (1992) Biosensors Bioelectron. , vol.7 , pp. 695-700
    • Yabuki, S.1    Mizutani, F.2    Katsura, T.3
  • 5
    • 0027593812 scopus 로고
    • Electrical communication of polyethylene glycol-modified glucose oxidase in carbon paste and its application to the assay of glucose
    • S. Yabuki, F. Mizutani and T. Katsura, Electrical communication of polyethylene glycol-modified glucose oxidase in carbon paste and its application to the assay of glucose, Sensors and Actuators B, 13-14 (1993) 166-168.
    • (1993) Sensors and Actuators B , vol.13-14 , pp. 166-168
    • Yabuki, S.1    Mizutani, F.2    Katsura, T.3
  • 6
    • 0028442888 scopus 로고
    • Choline-sensing electrode based on polyethylene glycol-modified enzyme and mediator
    • S. Yabuki, F. Mizutani and T. Katsura, Choline-sensing electrode based on polyethylene glycol-modified enzyme and mediator, Sensors and Actuators B, 20 (1994) 159-162.
    • (1994) Sensors and Actuators B , vol.20 , pp. 159-162
    • Yabuki, S.1    Mizutani, F.2    Katsura, T.3
  • 7
    • 0028250033 scopus 로고
    • Surface modification of horseradish peroxidase with poly (ethylene glycol)s of various relative molecular masses (M): Relationship between the M of poly(ethylene glycol) and the stability of horseradish peroxidase-poly(ethylene glycol) adducts under various denaturing conditions, biotechnol
    • M. Laliberté, J.-C. Gayet and G. Portier, Surface modification of horseradish peroxidase with poly (ethylene glycol)s of various relative molecular masses (M): relationship between the M of poly(ethylene glycol) and the stability of horseradish peroxidase-poly(ethylene glycol) adducts under various denaturing conditions, Biotechnol. Appl. Biochem., 20 (1994) 397-413.
    • (1994) Appl. Biochem. , vol.20 , pp. 397-413
    • Laliberté, M.1    Gayet, J.-C.2    Portier, G.3
  • 8
    • 0022444792 scopus 로고
    • Application of polyethylene glycol-modified enzymes in biotechnological processes: Organic solvent-soluble enzymes
    • Y. Inada, K. Takahashi, T. Yoshimoto, A. Ajima, A. Matsushima and Y. Saito, Application of polyethylene glycol-modified enzymes in biotechnological processes: organic solvent-soluble enzymes, Trends Biotechnol., 4 (1986) 190-194.
    • (1986) Trends Biotechnol. , vol.4 , pp. 190-194
    • Inada, Y.1    Takahashi, K.2    Yoshimoto, T.3    Ajima, A.4    Matsushima, A.5    Saito, Y.6
  • 9
    • 0024032116 scopus 로고
    • Application of PEG-enzyme and magnetite-PEG-enzyme conjugates for biotechnological processes
    • Y. Inada, K. Takahashi, T. Yoshimoto, Y. Kodera, A. Matsushima and Y. Saito, Application of PEG-enzyme and magnetite-PEG-enzyme conjugates for biotechnological processes, Trends Biotechnol., 6 (1988) 131-134.
    • (1988) Trends Biotechnol. , vol.6 , pp. 131-134
    • Inada, Y.1    Takahashi, K.2    Yoshimoto, T.3    Kodera, Y.4    Matsushima, A.5    Saito, Y.6
  • 10
    • 0029256554 scopus 로고
    • Modification of a carbon paste glucose-sensing enzyme electrode and a reduction in the electrochemical interference from L-ascorbate
    • S. Yabuki and F. Mizutani, Modification of a carbon paste glucose-sensing enzyme electrode and a reduction in the electrochemical interference from L-ascorbate., Biosensors Bioelectron., 10 (1995) 353-358.
    • (1995) Biosensors Bioelectron. , vol.10 , pp. 353-358
    • Yabuki, S.1    Mizutani, F.2
  • 11
    • 0000409865 scopus 로고
    • Surface modification of horseradish peroxidase with poly(ethylene glycol)s of various molecular masses
    • G. Fortier and M. Laliberté, Surface modification of horseradish peroxidase with poly(ethylene glycol)s of various molecular masses, Biotechnol. Appl. Biochem., 17 (1993) 115-130.
    • (1993) Biotechnol. Appl. Biochem. , vol.17 , pp. 115-130
    • Fortier, G.1    Laliberté, M.2
  • 12
    • 0028121678 scopus 로고
    • Observation of direct electron transfer from the active center of glucose oxidase to a graphite electrode achieved through the use of mild immobilization
    • M. Alvarez-Icaza and R.D. Schmid, Observation of direct electron transfer from the active center of glucose oxidase to a graphite electrode achieved through the use of mild immobilization, Bioelectrochem. Bioenergetics, 33 (1994) 191-199.
    • (1994) Bioelectrochem. Bioenergetics , vol.33 , pp. 191-199
    • Alvarez-Icaza, M.1    Schmid, R.D.2
  • 13
    • 0021762558 scopus 로고
    • Polyethylene glycol-modified catalase exhibits unexpectedly high activity in benzene
    • K. Takahashi, A. Ajima, T. Yoshimoto and Y. Inada, Polyethylene glycol-modified catalase exhibits unexpectedly high activity in benzene, Biochem. Biophys. Res. Commun., 125 (1984) 761-766.
    • (1984) Biochem. Biophys. Res. Commun. , vol.125 , pp. 761-766
    • Takahashi, K.1    Ajima, A.2    Yoshimoto, T.3    Inada, Y.4
  • 14
    • 0014949207 scopus 로고
    • Cleavage of structural proteins during the assembly of the head of Bacteriophage T4
    • U.K. Laemmli, Cleavage of structural proteins during the assembly of the head of Bacteriophage T4, Nature, 227 (1970) 680-685.
    • (1970) Nature , vol.227 , pp. 680-685
    • Laemmli, U.K.1
  • 15
    • 0000031263 scopus 로고
    • Enzymatic determination of glucose in a flow system by catalytic oxidation of the nicotinamide coenzyme at a modified electrode
    • R. Appelqvist, G. Marko-Varga, L. Gorton, A. Torstensson and G. Johansson, Enzymatic determination of glucose in a flow system by catalytic oxidation of the nicotinamide coenzyme at a modified electrode, Anal. Chim. Acta, 169 (1985) 237-247.
    • (1985) Anal. Chim. Acta , vol.169 , pp. 237-247
    • Appelqvist, R.1    Marko-Varga, G.2    Gorton, L.3    Torstensson, A.4    Johansson, G.5
  • 16
    • 58149364211 scopus 로고
    • Kinetic models of horseradish peroxidase action on a graphite electrode
    • T. Ruzgas, L. Gorton, J. Emnéus and G. Marko-Varga, Kinetic models of horseradish peroxidase action on a graphite electrode, J. Electroanal. Chem., 391 (1995) 41-49.
    • (1995) J. Electroanal. Chem. , vol.391 , pp. 41-49
    • Ruzgas, T.1    Gorton, L.2    Emnéus, J.3    Marko-Varga, G.4
  • 17
    • 0001556059 scopus 로고
    • Spectrophotometric and electrochemical kinetic studies of poly(ethylene glycol)-modified horseradish peroxidase reactions in organic solvents and aqueous buffers
    • L. Yang and R.W. Murray, Spectrophotometric and electrochemical kinetic studies of poly(ethylene glycol)-modified horseradish peroxidase reactions in organic solvents and aqueous buffers, Anal. Chem., 66 (1994) 2710-2718.
    • (1994) Anal. Chem. , vol.66 , pp. 2710-2718
    • Yang, L.1    Murray, R.W.2