메뉴 건너뛰기




Volumn 6, Issue 5, 1996, Pages 326-329

Volumetric assessment of preload in trauma patients: Addressing the problem of mathematical coupling

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD PRESSURE; CENTRAL VENOUS PRESSURE; CLINICAL TRIAL; COMPARATIVE STUDY; DIASTOLE; HEART OUTPUT; HEART RIGHT VENTRICLE FUNCTION; HUMAN; INJURY; METHODOLOGY; MONITORING; PATHOPHYSIOLOGY; PHYSIOLOGY; PREDICTION AND FORECASTING; PULMONARY ARTERY; THEORETICAL MODEL; THERMODILUTION;

EID: 0030281706     PISSN: 10732322     EISSN: None     Source Type: Journal    
DOI: 10.1097/00024382-199611000-00004     Document Type: Article
Times cited : (27)

References (18)
  • 1
    • 0019412741 scopus 로고
    • Thermodilution right ventricular volume: A novel and better predictor of volume replacement in acute thermal injury
    • Martyn JJ, Snider MT, Farago LF, et al: Thermodilution right ventricular volume: A novel and better predictor of volume replacement in acute thermal injury. J Trauma 21:619-626, 1981.
    • (1981) J Trauma , vol.21 , pp. 619-626
    • Martyn, J.J.1    Snider, M.T.2    Farago, L.F.3
  • 2
    • 0026631780 scopus 로고
    • End-diastolic volume - A better indicator of preload in the critically ill
    • Diebel LN, Wilson RF, Tagett MG, et al: End-diastolic volume - A better indicator of preload in the critically ill. Arch Surg 127:817-821, 1992.
    • (1992) Arch Surg , vol.127 , pp. 817-821
    • Diebel, L.N.1    Wilson, R.F.2    Tagett, M.G.3
  • 3
    • 0028596566 scopus 로고
    • End-diastolic volume versus pulmonary artery wedge pressure in evaluating cardiac preload in trauma patients
    • Diebel LN, Wilson RF, Heins J, et al: End-diastolic volume versus pulmonary artery wedge pressure in evaluating cardiac preload in trauma patients. J Trauma 37:950-955, 1994
    • (1994) J Trauma , vol.37 , pp. 950-955
    • Diebel, L.N.1    Wilson, R.F.2    Heins, J.3
  • 4
    • 0029023784 scopus 로고
    • Right ventricular end-diastolic volume as a measure of preload
    • Durham R, Neunaber K, Vogler G, et al: Right ventricular end-diastolic volume as a measure of preload. J Trauma 39:218-224, 1995.
    • (1995) J Trauma , vol.39 , pp. 218-224
    • Durham, R.1    Neunaber, K.2    Vogler, G.3
  • 5
    • 0029979828 scopus 로고    scopus 로고
    • Preload assessment in trauma patients during large volume resuscitation
    • Chang MC, Blinman TA, Rutherford EJ, et al: Preload assessment in trauma patients during large volume resuscitation. Arch Surg 131:728-731, 1996.
    • (1996) Arch Surg , vol.131 , pp. 728-731
    • Chang, M.C.1    Blinman, T.A.2    Rutherford, E.J.3
  • 6
    • 0019475622 scopus 로고
    • Mathematic coupling of data - A common source of error
    • Archie JP: Mathematic coupling of data - A common source of error. Ann Surg 19:296-303, 1981.
    • (1981) Ann Surg , vol.19 , pp. 296-303
    • Archie, J.P.1
  • 7
    • 0022474749 scopus 로고
    • Mathematical coupling of data: Correction of a common error for linear calculations
    • Moreno LF, Stratton HH, Newell JC, Feustel PJ: Mathematical coupling of data: Correction of a common error for linear calculations. J Appl Physiol 60:335-343, 1986.
    • (1986) J Appl Physiol , vol.60 , pp. 335-343
    • Moreno, L.F.1    Stratton, H.H.2    Newell, J.C.3    Feustel, P.J.4
  • 8
    • 0023225905 scopus 로고
    • Regression of calculated variables in the presence of shared measurement error
    • Stratton HH, Feustel PJ, Newell JC: Regression of calculated variables in the presence of shared measurement error. J Appl Physiol 62:2083-2093, 1987.
    • (1987) J Appl Physiol , vol.62 , pp. 2083-2093
    • Stratton, H.H.1    Feustel, P.J.2    Newell, J.C.3
  • 9
    • 0025774801 scopus 로고
    • Validation of an indirect calorimeter to measure oxygen consumption in critically ill patients
    • Ronco JJ, Phang PT: Validation of an indirect calorimeter to measure oxygen consumption in critically ill patients. J Crit Care 6:36-41, 1991.
    • (1991) J Crit Care , vol.6 , pp. 36-41
    • Ronco, J.J.1    Phang, P.T.2
  • 10
    • 0345823228 scopus 로고
    • Distributional changes in extracellular fluid during acute hemorrhagic shock
    • Shires T, Brown FT, Canizaro PC, Sommerville N: Distributional changes in extracellular fluid during acute hemorrhagic shock. Surgical Forum 11:115-117, 1960.
    • (1960) Surgical Forum , vol.11 , pp. 115-117
    • Shires, T.1    Brown, F.T.2    Canizaro, P.C.3    Sommerville, N.4
  • 12
    • 0014201437 scopus 로고
    • Balanced salt solution in the treatment of hemorrhagic shock
    • McClelland RN, Shires GT, Baxter CR, Coln CD: Balanced salt solution in the treatment of hemorrhagic shock. JAMA 199:830-834, 1967.
    • (1967) JAMA , vol.199 , pp. 830-834
    • McClelland, R.N.1    Shires, G.T.2    Baxter, C.R.3    Coln, C.D.4
  • 13
    • 0026517006 scopus 로고
    • Continuous measurement of cardiac output by the Fick principle: Clinical validation in intensive care
    • Keinanen O, Takula J, Kari A: Continuous measurement of cardiac output by the Fick principle: clinical validation in intensive care. Crit Care Med 20:360-365, 1992.
    • (1992) Crit Care Med , vol.20 , pp. 360-365
    • Keinanen, O.1    Takula, J.2    Kari, A.3
  • 14
    • 0027228039 scopus 로고
    • Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake
    • Nakanishi N, Yoshioka T, Okano Y, et al: Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake. Chest 104:419-426, 1993.
    • (1993) Chest , vol.104 , pp. 419-426
    • Nakanishi, N.1    Yoshioka, T.2    Okano, Y.3
  • 15
    • 0028076648 scopus 로고
    • Oxygen Fick and modified carbon dioxide Fick cardiac outputs
    • Mahutte CK, Jaffe MB, Chen PA, et al: Oxygen Fick and modified carbon dioxide Fick cardiac outputs. Crit Care Med 22:86-95, 1994.
    • (1994) Crit Care Med , vol.22 , pp. 86-95
    • Mahutte, C.K.1    Jaffe, M.B.2    Chen, P.A.3
  • 16
    • 0025340383 scopus 로고
    • Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation
    • Lynch J, Kaemmerer H: Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation. Intensive Care Med 16:248-251, 1990.
    • (1990) Intensive Care Med , vol.16 , pp. 248-251
    • Lynch, J.1    Kaemmerer, H.2
  • 17
    • 0026639782 scopus 로고
    • The validity of cardiac output measurement by thoracic impedance: A meta-analysis
    • Fuller HD: The validity of cardiac output measurement by thoracic impedance: A meta-analysis. Clin Invest Med 15:103-112, 1992.
    • (1992) Clin Invest Med , vol.15 , pp. 103-112
    • Fuller, H.D.1
  • 18
    • 0016200328 scopus 로고
    • Influence of right ventricular filling pressure on left ventricular pressure and dimension
    • Bemis CE, Serur JR, Borkenhagen D, et al: Influence of right ventricular filling pressure on left ventricular pressure and dimension. Circ Res 34:498-504, 1974.
    • (1974) Circ Res , vol.34 , pp. 498-504
    • Bemis, C.E.1    Serur, J.R.2    Borkenhagen, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.