메뉴 건너뛰기




Volumn 6, Issue 6, 1996, Pages 939-943

Automatic removal of extrameningeal tissues from MR images of human brain

Author keywords

Brain; Extrameningeal tissues; FLAIR; Magnetic resonance imaging (MRI); MTC; Segmentation

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT; BRAIN; COMPARATIVE STUDY; EVALUATION; FILTRATION; HISTOLOGY; HUMAN; INSTRUMENTATION; MENINX; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; TIME;

EID: 0030278974     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880060616     Document Type: Article
Times cited : (10)

References (11)
  • 2
    • 0023619152 scopus 로고
    • 3D reconstruction of the brain from magnetic resonance images using a connectivity algorithm
    • Cline H, Dumoulin C, Hart JH, Lorensen W. 3D reconstruction of the brain from magnetic resonance images using a connectivity algorithm. Magn Reson Imaging 1987; 5: 345-352.
    • (1987) Magn Reson Imaging , vol.5 , pp. 345-352
    • Cline, H.1    Dumoulin, C.2    Hart, J.H.3    Lorensen, W.4
  • 6
    • 0025465145 scopus 로고
    • Scale-space and edge detection using anisotropic diffusion
    • Perona P, Malik J. Scale-space and edge detection using anisotropic diffusion. IEEE Trans PAMI 1990; 12:629-639.
    • (1990) IEEE Trans PAMI , vol.12 , pp. 629-639
    • Perona, P.1    Malik, J.2
  • 7
    • 0021254150 scopus 로고
    • A signal-to-noise calibration procedure for NMR imaging systems
    • Edelstein WA, Bottomley PA, Pfeifer LM. A signal-to-noise calibration procedure for NMR imaging systems. Med Phys 1984; 11: 180-185.
    • (1984) Med Phys , vol.11 , pp. 180-185
    • Edelstein, W.A.1    Bottomley, P.A.2    Pfeifer, L.M.3
  • 8
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985; 112:232-233.
    • (1985) Med Phys , vol.112 , pp. 232-233
    • Henkelman, R.M.1
  • 9
    • 0028507388 scopus 로고
    • Reproducibility of nonparametric feature map segmentation for determination of normal human intracranial volumes with MR imaging data
    • Jackson EF, Narayana PA, Falconer JC. Reproducibility of nonparametric feature map segmentation for determination of normal human intracranial volumes with MR imaging data. J Magn Reson Imaging 1994; 4: 692-700.
    • (1994) J Magn Reson Imaging , vol.4 , pp. 692-700
    • Jackson, E.F.1    Narayana, P.A.2    Falconer, J.C.3
  • 10
    • 0028963671 scopus 로고
    • Effect of radiofrequency inhomogeneity correction on the reproducibility of intra-cranial volumes using MR image data
    • Narayana PA, Borthakur A. Effect of radiofrequency inhomogeneity correction on the reproducibility of intra-cranial volumes using MR image data. Magn Reson Med 1995; 33:396-400.
    • (1995) Magn Reson Med , vol.33 , pp. 396-400
    • Narayana, P.A.1    Borthakur, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.