메뉴 건너뛰기




Volumn 9, Issue 6, 1996, Pages 520-526

Thickness and accuracy of superplastic Ti-6Al-4V alloy denture frameworks

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; TITANIUM; TITANIUM ALLOY (TIAL6V4);

EID: 0030276098     PISSN: 08932174     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (30)
  • 3
    • 0020339536 scopus 로고
    • Effect of magnesia investments in the dental casting of pure titanium or titanium alloys
    • Ida K, Togaya T, Tsutsumi S, Takeuchi M. Effect of magnesia investments in the dental casting of pure titanium or titanium alloys. Dent Mater J 1982;1:8-21.
    • (1982) Dent Mater J , vol.1 , pp. 8-21
    • Ida, K.1    Togaya, T.2    Tsutsumi, S.3    Takeuchi, M.4
  • 4
    • 0642359226 scopus 로고
    • Properties of dental castability of Ti and Ti-6Al-4V
    • Greener EH, Moser JB, Opp J, Szurgot K, Marker BC. Properties of dental castability of Ti and Ti-6Al-4V [abstract 1190]. J Dent Res 1986;65(special issue):301.
    • (1986) J Dent Res , vol.65 , Issue.SPEC. ISSUE , pp. 301
    • Greener, E.H.1    Moser, J.B.2    Opp, J.3    Szurgot, K.4    Marker, B.C.5
  • 5
    • 0041694958 scopus 로고
    • Production of a cast titanium-base partial denture
    • Waterstrat RM, Rupp NW, Franklin O. Production of a cast titanium-base partial denture [abstract 717]. J Dent Res 1978;57(special issue):254.
    • (1978) J Dent Res , vol.57 , Issue.SPEC. ISSUE , pp. 254
    • Waterstrat, R.M.1    Rupp, N.W.2    Franklin, O.3
  • 6
    • 0025395776 scopus 로고
    • Mechanical studies on casting titanium alloy denture base
    • Ito M. Mechanical studies on casting titanium alloy denture base. J Stomatol Soc Jpn 1990;57:146-164.
    • (1990) J Stomatol Soc Jpn , vol.57 , pp. 146-164
    • Ito, M.1
  • 8
    • 0026110677 scopus 로고
    • Dimensional changes in casting titanium removable partial denture frameworks
    • Blackman R, Barghi N, Tran C. Dimensional changes in casting titanium removable partial denture frameworks. J Prosthet Dent 1991;65:309-315.
    • (1991) J Prosthet Dent , vol.65 , pp. 309-315
    • Blackman, R.1    Barghi, N.2    Tran, C.3
  • 9
    • 0001379899 scopus 로고
    • Corrosion resistance on the reacted surface of titanium castings with a phosphate bonded silica investment
    • Doi H, Yoneyama T, Kotake M, Hamanaka H. Corrosion resistance on the reacted surface of titanium castings with a phosphate bonded silica investment. J J Dent Mater 1992;11:672-678.
    • (1992) J J Dent Mater , vol.11 , pp. 672-678
    • Doi, H.1    Yoneyama, T.2    Kotake, M.3    Hamanaka, H.4
  • 10
    • 3042807350 scopus 로고
    • Influence of surface reaction layer on mechanical properties of titanium castings
    • Doi H, Yoneyama T, Kotake M, Hamanaka H. Influence of surface reaction layer on mechanical properties of titanium castings. J J Dent Mater 1992;11:817-822.
    • (1992) J J Dent Mater , vol.11 , pp. 817-822
    • Doi, H.1    Yoneyama, T.2    Kotake, M.3    Hamanaka, H.4
  • 12
    • 0027620312 scopus 로고
    • The fit of procera titanium crowns
    • Karlsson S. The fit of procera titanium crowns. Acta Odonol Scand 1993;51:129-134.
    • (1993) Acta Odonol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 13
    • 0028476137 scopus 로고
    • A comparison of the fit of spark-eroded titanium copings and cast gold alloy copings
    • Harris IR, Wickens JL. A comparison of the fit of spark-eroded titanium copings and cast gold alloy copings. Int J Prosthodont 1994;7:348-355.
    • (1994) Int J Prosthodont , vol.7 , pp. 348-355
    • Harris, I.R.1    Wickens, J.L.2
  • 14
    • 0028506796 scopus 로고
    • Marginal fit of machine-milled titanium and cast titanium single crowns
    • Leong D, Chai J, Lautenschlager E, Gilbert J. Marginal fit of machine-milled titanium and cast titanium single crowns. Int J Prosthodont 1994;7:440-447.
    • (1994) Int J Prosthodont , vol.7 , pp. 440-447
    • Leong, D.1    Chai, J.2    Lautenschlager, E.3    Gilbert, J.4
  • 15
    • 0029399387 scopus 로고
    • A new computer-assisted method for fabrication of crowns and fixed partial dentures
    • Russell MM, Andersson M, Dahlmo K, Razzoog ME, Lang BR. A new computer-assisted method for fabrication of crowns and fixed partial dentures. Quintessence Int 1995;26:757-763.
    • (1995) Quintessence Int , vol.26 , pp. 757-763
    • Russell, M.M.1    Andersson, M.2    Dahlmo, K.3    Razzoog, M.E.4    Lang, B.R.5
  • 16
    • 49649137233 scopus 로고
    • Superplasticity in large grained materials
    • Griffiths P, Hammond C. Superplasticity in large grained materials. Acta Metallurgica 1972;20:935-945.
    • (1972) Acta Metallurgica , vol.20 , pp. 935-945
    • Griffiths, P.1    Hammond, C.2
  • 18
    • 0024725647 scopus 로고
    • Application of superplastic titanium alloy for denture base
    • Ito M, Okuno O, Ai M, Miura I. Application of superplastic titanium alloy for denture base. J Stomatol Soc Jpn 1989;56:429-434.
    • (1989) J Stomatol Soc Jpn , vol.56 , pp. 429-434
    • Ito, M.1    Okuno, O.2    Ai, M.3    Miura, I.4
  • 19
    • 0024893616 scopus 로고
    • The clinical evaluation of the metal-based denture using superplastic titanium alloy for upper edentulous patients
    • Onodera S, Hosoi T, Morito M, Miwa E, Okikura Y, Tsuchida F, et al. The clinical evaluation of the metal-based denture using superplastic titanium alloy for upper edentulous patients. J Jpn Prosthodont Soc 1989;33(6):1381-1387.
    • (1989) J Jpn Prosthodont Soc , vol.33 , Issue.6 , pp. 1381-1387
    • Onodera, S.1    Hosoi, T.2    Morito, M.3    Miwa, E.4    Okikura, Y.5    Tsuchida, F.6
  • 20
    • 0026822916 scopus 로고
    • Mechanical property and adaptability of superplastic titanium alloy denture base
    • Wakabayashi N. Mechanical property and adaptability of superplastic titanium alloy denture base. J Stomatol Soc Jpn 1992;59:90-109.
    • (1992) J Stomatol Soc Jpn , vol.59 , pp. 90-109
    • Wakabayashi, N.1
  • 22
    • 0039970876 scopus 로고
    • A functional stress analysis of the maxillary complete denture base
    • Lambrecht JR, Kydd WL. A functional stress analysis of the maxillary complete denture base. J Prosthet Dent 1962;12:865-872.
    • (1962) J Prosthet Dent , vol.12 , pp. 865-872
    • Lambrecht, J.R.1    Kydd, W.L.2
  • 23
    • 24144453011 scopus 로고
    • Diffusion bonding to titanium alloys during superplastic forming
    • Okuno O, Nakano T, Hamanaka H, Kato I. Diffusion bonding to titanium alloys during superplastic forming. J J Dent Mater 1991;10:483-491.
    • (1991) J J Dent Mater , vol.10 , pp. 483-491
    • Okuno, O.1    Nakano, T.2    Hamanaka, H.3    Kato, I.4
  • 24
    • 24144447779 scopus 로고
    • The adaptability of cast metal denture: Complete dentures
    • Hasegawa K. The adaptability of cast metal denture: Complete dentures. J Japan Prosthodont Soc 1976;20:423-447.
    • (1976) J Japan Prosthodont Soc , vol.20 , pp. 423-447
    • Hasegawa, K.1
  • 25
    • 24144441639 scopus 로고
    • The fit of maxillary complete dentures having metal bases: Part 1, observation of the metal bases
    • Gonda Y, Kawamura T, Nishiura M. The fit of maxillary complete dentures having metal bases: Part 1, Observation of the metal bases. J Japan Prosthodont Soc 1986;30:853-859.
    • (1986) J Japan Prosthodont Soc , vol.30 , pp. 853-859
    • Gonda, Y.1    Kawamura, T.2    Nishiura, M.3
  • 26
    • 24144502290 scopus 로고
    • The adaptability of cast metal denture: Partial dentures
    • Matsumura S. The adaptability of cast metal denture: Partial dentures. J Japan Prosthodont Soc 1978;22:140-165.
    • (1978) J Japan Prosthodont Soc , vol.22 , pp. 140-165
    • Matsumura, S.1
  • 27
    • 24144443716 scopus 로고
    • Basic studies on the adaptation of cast metal denture plate
    • Yamada T. Basic studies on the adaptation of cast metal denture plate. J Japan Prosthodont Soc 1979;23:288-309.
    • (1979) J Japan Prosthodont Soc , vol.23 , pp. 288-309
    • Yamada, T.1
  • 28
    • 0018443898 scopus 로고
    • A comparison of the casting accuracy of base metal and gold alloys
    • Pulskamp FE. A comparison of the casting accuracy of base metal and gold alloys. J Prosthet Dent 1979;41:272-276.
    • (1979) J Prosthet Dent , vol.41 , pp. 272-276
    • Pulskamp, F.E.1
  • 29
    • 0025389040 scopus 로고
    • Bending behavior of superplastic titanium alloy for denture base
    • Wakabayashi N, Ai M, Okuno O. Bending behavior of superplastic titanium alloy for denture base. J J Dent Mater 1990;9:271-278.
    • (1990) J J Dent Mater , vol.9 , pp. 271-278
    • Wakabayashi, N.1    Ai, M.2    Okuno, O.3
  • 30
    • 24144479704 scopus 로고
    • Interface properties between the superplastic titanium alloy and the adhesive denture base resin
    • Wakabayashi N, Yatabe M, Ai M. Interface properties between the superplastic titanium alloy and the adhesive denture base resin. J Japan Prosthodont Soc 1995;39:333-340.
    • (1995) J Japan Prosthodont Soc , vol.39 , pp. 333-340
    • Wakabayashi, N.1    Yatabe, M.2    Ai, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.