메뉴 건너뛰기




Volumn 11, Issue 7, 1996, Pages 410-417

Microcirculation in the footsole as a function of mechanical pressure

Author keywords

Footsole; Laser doppler fluxmetry; Microcirculation; Pressure; Reactive hyperaemia

Indexed keywords

BLOOD; LASER DOPPLER VELOCIMETERS; PRESSURE EFFECTS;

EID: 0030272132     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/0268-0033(96)00021-6     Document Type: Article
Times cited : (12)

References (20)
  • 3
    • 0002444970 scopus 로고
    • Pressure sores - The problem
    • Kenedi RM, Cowden JM, Scales JT, eds. McMillan, London
    • 3 Brand PW. Pressure sores - the problem. In: Kenedi RM, Cowden JM, Scales JT, eds. Bedsore Biomechanics McMillan, London, 1976
    • (1976) Bedsore Biomechanics
    • Brand, P.W.1
  • 4
    • 0000599641 scopus 로고
    • Micro circulation and the diabetic foot
    • 4 Flynn MD, Tooke JE. Micro circulation and the diabetic foot. Vasc Med Rev 1990; 1: 121-38
    • (1990) Vasc Med Rev , vol.1 , pp. 121-138
    • Flynn, M.D.1    Tooke, J.E.2
  • 5
    • 0024785647 scopus 로고
    • Characteristics of skin blood flow over the trochanter under constant, prolonged pressure
    • 5 Franz RA, Xakellis GC. Characteristics of skin blood flow over the trochanter under constant, prolonged pressure. Am J Phys Med Rehabil 1989; 68: 272-6
    • (1989) Am J Phys Med Rehabil , vol.68 , pp. 272-276
    • Franz, R.A.1    Xakellis, G.C.2
  • 7
    • 0002621938 scopus 로고
    • The importance of abnormal foot pressure and gait in the causation of foot ulcers
    • Conner H, Boulton AJM, Ward JD, eds. John Wiley, Chichester
    • 7 Boulton AJM. The importance of abnormal foot pressure and gait in the causation of foot ulcers. In: Conner H, Boulton AJM, Ward JD, eds. The Foot in Diabetes. John Wiley, Chichester, 1987; 11-21
    • (1987) The Foot in Diabetes , pp. 11-21
    • Boulton, A.J.M.1
  • 8
    • 0017281089 scopus 로고
    • Effects of external pressure loading on human skin blood flow measured by 133Xe clearance
    • 8 Holloway GA, Daly CH, Kennedy D, Chimoskey J. Effects of external pressure loading on human skin blood flow measured by 133Xe clearance. J Appl Physiol 1976; 40: 597-600
    • (1976) J Appl Physiol , vol.40 , pp. 597-600
    • Holloway, G.A.1    Daly, C.H.2    Kennedy, D.3    Chimoskey, J.4
  • 9
    • 0019225916 scopus 로고
    • Evaluation of a laser Doppler flowmeter for measurement of tissue bloodflow
    • 9 Nilsson GE, Tenland T. Oberg PA. Evaluation of a laser Doppler flowmeter for measurement of tissue bloodflow. IEEE Trans Biomed Eng BME 1980; 27: 597-604
    • (1980) IEEE Trans Biomed Eng BME , vol.27 , pp. 597-604
    • Nilsson, G.E.1    Tenland, T.2    Oberg, P.A.3
  • 12
    • 0021861246 scopus 로고
    • Fluorescein flowmetry - A method for measuring a relative capillary blood flow in the testine
    • 12 Perbeck L, Lund F, Svensson L, Thulin L. Fluorescein flowmetry - a method for measuring a relative capillary blood flow in the testine. Clin Physiol 1985; 5: 337-46
    • (1985) Clin Physiol , vol.5 , pp. 337-346
    • Perbeck, L.1    Lund, F.2    Svensson, L.3    Thulin, L.4
  • 13
    • 0019230971 scopus 로고
    • A new instrument for continuous measurements of tissue blood flow by light-beating spectroscopy
    • 13 Nilsson GE, Tenland T, Oberg PA. A new instrument for continuous measurements of tissue blood flow by light-beating spectroscopy. IEEE Trans Biomed Eng BME 1980; 27: 12-19
    • (1980) IEEE Trans Biomed Eng BME , vol.27 , pp. 12-19
    • Nilsson, G.E.1    Tenland, T.2    Oberg, P.A.3
  • 14
    • 0022614885 scopus 로고
    • Impaired microvascular hyperaemic response to minor skin trauma in type I diabetes
    • 14 Rayman G. Williams SA, Spencer PD, Smaje LH, Wise PH, Tooke JE. Impaired microvascular hyperaemic response to minor skin trauma in type I diabetes. Br Med J 1986; 292: 1295-8
    • (1986) Br Med J , vol.292 , pp. 1295-1298
    • Rayman, G.1    Williams, S.A.2    Spencer, P.D.3    Smaje, L.H.4    Wise, P.H.5    Tooke, J.E.6
  • 15
    • 0026228187 scopus 로고
    • Effect of orthodontic forces on blood flow in human gingiva
    • 15 Yamaguchi K, Nanda RS, Kawata T. Effect of orthodontic forces on blood flow in human gingiva. Angle Orthod 1991; 61: 193-203
    • (1991) Angle Orthod , vol.61 , pp. 193-203
    • Yamaguchi, K.1    Nanda, R.S.2    Kawata, T.3
  • 17
    • 0023877194 scopus 로고
    • Temperature-dependent interaction between vascoconstrictor and vascodilator mechanisms in human skin
    • 17 Oberle J, Elam M, Karlsson T, Wallin BG. Temperature-dependent interaction between vascoconstrictor and vascodilator mechanisms in human skin. Acta Physiol Scand 1988; 132: 459-69
    • (1988) Acta Physiol Scand , vol.132 , pp. 459-469
    • Oberle, J.1    Elam, M.2    Karlsson, T.3    Wallin, B.G.4
  • 18
    • 0024536250 scopus 로고
    • Laser Doppler flowmetry in evaluation of skin post-ischaemic reactive hyperaemia
    • 18 Kvernebo K, Slagsvold CE, Stranden E. Laser Doppler flowmetry in evaluation of skin post-ischaemic reactive hyperaemia. J Cardiovasc Surg 1989; 30: 70-5
    • (1989) J Cardiovasc Surg , vol.30 , pp. 70-75
    • Kvernebo, K.1    Slagsvold, C.E.2    Stranden, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.