메뉴 건너뛰기




Volumn 33, Issue 4, 1996, Pages 355-362

An equivalent input noise level criterion for hearing aids

Author keywords

equivalent input noise level; hearing aids; internal noise

Indexed keywords

ACOUSTIC NOISE; ACOUSTIC NOISE MEASUREMENT; AUDITION; FREQUENCY RESPONSE; SPEECH COMMUNICATION;

EID: 0030271529     PISSN: 07487711     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (11)
  • 1
    • 10244265988 scopus 로고
    • ANSI S3.7-1973. New York: American National Standards Institute
    • American National Standards Institute. Method for coupler calibration of earphones. ANSI S3.7-1973. New York: American National Standards Institute, 1973.
    • (1973) Method for Coupler Calibration of Earphones
  • 3
    • 0022741865 scopus 로고
    • Updated performance requirements for hearing aids
    • Macrae JH, Dillon H. Updated performance requirements for hearing aids. J Rehabil Res Dev 1986:23:41-56.
    • (1986) J Rehabil Res Dev , vol.23 , pp. 41-56
    • Macrae, J.H.1    Dillon, H.2
  • 4
    • 0026334544 scopus 로고
    • Allowing for real ear venting effects when selecting the coupler gain of hearing aids
    • Dillon H. Allowing for real ear venting effects when selecting the coupler gain of hearing aids. Ear Hear 1991:12:406-16.
    • (1991) Ear Hear , vol.12 , pp. 406-416
    • Dillon, H.1
  • 5
    • 0000964957 scopus 로고
    • Modified hearing aid selection procedures for severe/profound hearing losses
    • Studebaker GA, Bess FH, Beck LB (eds.) Maryland: York Press
    • Byrne D, Parkinson A, Newall P. Modified hearing aid selection procedures for severe/profound hearing losses. In: Studebaker GA, Bess FH, Beck LB (eds.) The Vanderbilt hearing aid Report II, 295-300. Maryland: York Press, 1991.
    • (1991) The Vanderbilt Hearing Aid Report , vol.2 , pp. 295-300
    • Byrne, D.1    Parkinson, A.2    Newall, P.3
  • 6
    • 0022517008 scopus 로고
    • The National Acoustic Laboratories' (NAL) new procedure for selecting the gain and frequency response of a hearing aid
    • Byrne D, Dillon H. The National Acoustic Laboratories' (NAL) new procedure for selecting the gain and frequency response of a hearing aid. Ear Hear 1986:7:257-65.
    • (1986) Ear Hear , vol.7 , pp. 257-265
    • Byrne, D.1    Dillon, H.2
  • 7
    • 10244278819 scopus 로고
    • Modified hearing aid gain and frequency response requirements for severe/profound hearing loss
    • Sydney: National Acoustic Laboratories
    • Hodgson F, Dillon H. Modified hearing aid gain and frequency response requirements for severe/profound hearing loss. Audiology Circular 1989/23. Sydney: National Acoustic Laboratories, 1989.
    • (1989) Audiology Circular 1989/23
    • Hodgson, F.1    Dillon, H.2
  • 9
    • 0024502662 scopus 로고
    • Transfer functions and correction factors used in hearing aid evaluation and research
    • Bentler RA, Pavlović CV. Transfer functions and correction factors used in hearing aid evaluation and research. Ear Hear 1989:10:58-63.
    • (1989) Ear Hear , vol.10 , pp. 58-63
    • Bentler, R.A.1    Pavlović, C.V.2
  • 10
    • 0028860764 scopus 로고
    • Safety aspects of amplification for severe/profound hearing loss
    • Macrae JH. Safety aspects of amplification for severe/profound hearing loss. Aust J Audiol 1995:17: 27-37.
    • (1995) Aust J Audiol , vol.17 , pp. 27-37
    • Macrae, J.H.1
  • 11
    • 0029133913 scopus 로고
    • Additivity of masking in normally hearing and hearing-impaired subjects
    • Oxenham AJ, Moore BCJ. Additivity of masking in normally hearing and hearing-impaired subjects. J Acoust Soc Am 1995:98:1921-34.
    • (1995) J Acoust Soc Am , vol.98 , pp. 1921-1934
    • Oxenham, A.J.1    Moore, B.C.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.