메뉴 건너뛰기




Volumn 99, Issue 5, 1996, Pages 412-415

The significance of ictal depth EEG patterns in patients with temporal lobe epilepsy

Author keywords

Depth EEG; Epilepsy; Mesial temporal sclerosis; Outcome; Seizure morphology; Temporal lobe

Indexed keywords

ARTICLE; ELECTROENCEPHALOGRAM; GLIOSIS; HIPPOCAMPUS; HUMAN; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; SEIZURE; TEMPORAL LOBE EPILEPSY; TEMPORAL LOBECTOMY;

EID: 0030266718     PISSN: 00134694     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0013-4694(96)95120-2     Document Type: Article
Times cited : (45)

References (14)
  • 1
    • 0021751904 scopus 로고
    • Distribution of pyramidal cell density and hyperexcitability in the epileptic human hippocampal formation
    • Babb, T.L., Lieb, J.P., Brown, W.J., Pretorius, J. and Crandall, P.H. Distribution of pyramidal cell density and hyperexcitability in the epileptic human hippocampal formation. Epilepsia., 1984, 25: 721-728.
    • (1984) Epilepsia. , vol.25 , pp. 721-728
    • Babb, T.L.1    Lieb, J.P.2    Brown, W.J.3    Pretorius, J.4    Crandall, P.H.5
  • 2
    • 0023242042 scopus 로고
    • Intensive neurodiagnostic monitoring with intracranial electrodes
    • R.J. Gummit (Ed.), Raven Press, New York
    • Engel, Jr., J. and Crandall, P.H. Intensive neurodiagnostic monitoring with intracranial electrodes. In: R.J. Gummit (Ed.), Intensive Neurodiagnostic Monitoring. Advances in Neurology, Vol. 46. Raven Press, New York, 1986, pp. 85-106.
    • (1986) Intensive Neurodiagnostic Monitoring. Advances in Neurology , vol.46 , pp. 85-106
    • Engel J., Jr.1    Crandall, P.H.2
  • 4
    • 0026675544 scopus 로고
    • Ictal EEG waveforms from epidural electrodes predictive of seizure control after temporal lobectomy
    • Faught, E., Kuzniecky, R.I. and Hurst, D.C. Ictal EEG waveforms from epidural electrodes predictive of seizure control after temporal lobectomy. Electroenceph. clin. Neurophysiol., 1992, 83: 229-235.
    • (1992) Electroenceph. Clin. Neurophysiol. , vol.83 , pp. 229-235
    • Faught, E.1    Kuzniecky, R.I.2    Hurst, D.C.3
  • 5
    • 0005149901 scopus 로고
    • Depth electrode implantation
    • J. Engel (Ed.), Raven Press, New York
    • Flanigin, H.F. and Smith, J.R., Depth electrode implantation. In: J. Engel (Ed.), Surgical Treatment of the Epilepsies. Raven Press, New York, 1987, pp. 609-612.
    • (1987) Surgical Treatment of the Epilepsies , pp. 609-612
    • Flanigin, H.F.1    Smith, J.R.2
  • 7
    • 0002738975 scopus 로고
    • Frequency characteristics of neocortical and hippocampal onset seizures
    • Javidan, M., Katz, A., Tran, T., Pacia, S. and Spencer, S.S. Frequency characteristics of neocortical and hippocampal onset seizures. Epilepsia. 1992, 33 (Suppl. 3): 58.
    • (1992) Epilepsia , vol.33 , Issue.SUPPL. 3 , pp. 58
    • Javidan, M.1    Katz, A.2    Tran, T.3    Pacia, S.4    Spencer, S.S.5
  • 8
    • 0019417772 scopus 로고
    • Neuropathological findings following temporal lobectomy related to surface and deep EEG patterns
    • Lieb, J.P., Engel, Jr., J., Brown, W.J., Gevins, A. and Crandall, P.H. Neuropathological findings following temporal lobectomy related to surface and deep EEG patterns. Epilepsia, 1981, 22: 539-549.
    • (1981) Epilepsia , vol.22 , pp. 539-549
    • Lieb, J.P.1    Engel J., Jr.2    Brown, W.J.3    Gevins, A.4    Crandall, P.H.5
  • 9
    • 0025203568 scopus 로고
    • An 8-year experience with depth electrodes in the evaluation of ablative seizure surgery candidates
    • Smith, J.R., Flanigin, H.F., King, D.W., Gallagher, B.B. et al. An 8-year experience with depth electrodes in the evaluation of ablative seizure surgery candidates. Sterotact. Funct. Neurosurg., 1990, 54/55: 60-66.
    • (1990) Sterotact. Funct. Neurosurg. , vol.54-55 , pp. 60-66
    • Smith, J.R.1    Flanigin, H.F.2    King, D.W.3    Gallagher, B.B.4
  • 10
    • 0026643656 scopus 로고
    • Morphological patterns of seizures recorded intracranially
    • Spencer, S.S., Guimaraes, P., Katz, A., Kim, J. and Spencer. D. Morphological patterns of seizures recorded intracranially. Epilepsia, 1992a, 33: 537-545.
    • (1992) Epilepsia , vol.33 , pp. 537-545
    • Spencer, S.S.1    Guimaraes, P.2    Katz, A.3    Kim, J.4    Spencer, D.5
  • 12
    • 0002284504 scopus 로고
    • Clinicopathological correlations of low voltage fast and high amplitude spike and wave mesial temporal stereoencephalographic ictal onsets
    • Townsend, J.B. and Engel, Jr., J. Clinicopathological correlations of low voltage fast and high amplitude spike and wave mesial temporal stereoencephalographic ictal onsets. Epilepsia, 1991, 32 (Suppl. 3): 21.
    • (1991) Epilepsia , vol.32 , Issue.SUPPL. 3 , pp. 21
    • Townsend, J.B.1    Engel J., Jr.2
  • 13
    • 0026711145 scopus 로고
    • Long-term ictal monitoring with subdural strip electrodes: Prognostic factors for selecting temporal lobectomy candidates
    • Weinand, M.E., Wyler, A.R., Richey, E.T., Phillips, B.B. and Somes, G.W. Long-term ictal monitoring with subdural strip electrodes: prognostic factors for selecting temporal lobectomy candidates. J. Neurosurg., 1992, 77: 20-28.
    • (1992) J. Neurosurg. , vol.77 , pp. 20-28
    • Weinand, M.E.1    Wyler, A.R.2    Richey, E.T.3    Phillips, B.B.4    Somes, G.W.5
  • 14
    • 0026340905 scopus 로고
    • Analysis of foramen ovale electrode-recorded seizures and correlation with outcome following amygdalohippocampectomy
    • Wieser, H.G. and Siegel, A.M. Analysis of foramen ovale electrode-recorded seizures and correlation with outcome following amygdalohippocampectomy. Epilepsia, 1991, 32: 838-850.
    • (1991) Epilepsia , vol.32 , pp. 838-850
    • Wieser, H.G.1    Siegel, A.M.2