메뉴 건너뛰기




Volumn 25, Issue 5, 1996, Pages 339-343

A comparative study of two arbitrary face-bow transfer systems for orthognathic surgery planning

Author keywords

Face bow transfers; Orthognathic surgery

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; COMPARATIVE STUDY; DENTAL CARE; DENTAL EQUIPMENT; EQUIPMENT DESIGN; FEMALE; HUMAN; INCISOR; INSTRUMENTATION; MALE; MALOCCLUSION; MANDIBLE; MAXILLA; METHODOLOGY; OBSERVER VARIATION; PATHOLOGY; PATIENT CARE PLANNING; REPRODUCIBILITY; TOOTH OCCLUSION; TOOTH RADIOGRAPHY;

EID: 0030256267     PISSN: 09015027     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0901-5027(06)80025-1     Document Type: Article
Times cited : (28)

References (19)
  • 1
    • 0025608648 scopus 로고
    • Model surgery for orthognathic planning
    • ANWAR M, HARRIS M. Model surgery for orthognathic planning. Br J Oral Maxillofac Surg 1990: 28: 393-7.
    • (1990) Br J Oral Maxillofac Surg , vol.28 , pp. 393-397
    • Anwar, M.1    Harris, M.2
  • 2
    • 0040691008 scopus 로고
    • Hinge axis registration experiments on the articulator
    • BORGH O, POSSELT U. Hinge axis registration experiments on the articulator. J Prosthet Dent 1958: 8: 35-40.
    • (1958) J Prosthet Dent , vol.8 , pp. 35-40
    • Borgh, O.1    Posselt, U.2
  • 4
    • 0040691005 scopus 로고
    • The movements of the tempromandibular joint and their relation to the problem of occlusion
    • COLLETT HA. The movements of the tempromandibular joint and their relation to the problem of occlusion. J Prosthet Dent 1955: 27: 486-97.
    • (1955) J Prosthet Dent , vol.27 , pp. 486-497
    • Collett, H.A.1
  • 6
    • 0026715060 scopus 로고
    • Accuracy of face-bow transfer: Effect on surgical prediction and post-surgical results
    • ELLIS E, THARANON W, GAMBRELL K. Accuracy of face-bow transfer: effect on surgical prediction and post-surgical results. J Oral Maxillofac Surg 1992: 50: 562-7.
    • (1992) J Oral Maxillofac Surg , vol.50 , pp. 562-567
    • Ellis, E.1    Tharanon, W.2    Gambrell, K.3
  • 7
    • 0020853280 scopus 로고
    • An investigation of the reproducibility of face-bow transfers
    • GOLD BR, SETCHELL DJ. An investigation of the reproducibility of face-bow transfers. J Oral Rehab 1983: 10: 495-503.
    • (1983) J Oral Rehab , vol.10 , pp. 495-503
    • Gold, B.R.1    Setchell, D.J.2
  • 8
    • 0023776430 scopus 로고
    • Comparison of cast positions by using four face-bows
    • GOSKA JR, CHRISTENSEN LV. Comparison of cast positions by using four face-bows. J Prosthet Dent 1988: 59: 42-4.
    • (1988) J Prosthet Dent , vol.59 , pp. 42-44
    • Goska, J.R.1    Christensen, L.V.2
  • 9
    • 0018144327 scopus 로고
    • The use of an anatomic articulator in segmental orthognathic surgery
    • HOHL TH. The use of an anatomic articulator in segmental orthognathic surgery. Am J Orthod 1978: 73: 429-42.
    • (1978) Am J Orthod , vol.73 , pp. 429-442
    • Hohl, T.H.1
  • 10
    • 0038913184 scopus 로고
    • The indispensability of the face-bow and the effect of a short radius in full and partial dental construction
    • LOGAN JG. The indispensability of the face-bow and the effect of a short radius in full and partial dental construction. Dent Digest 1926: 32: 537-42.
    • (1926) Dent Digest , vol.32 , pp. 537-542
    • Logan, J.G.1
  • 11
    • 0022747201 scopus 로고
    • Simple hinge and semi-adjustable articulators in orthognathic surgery
    • MARKO JV. Simple hinge and semi-adjustable articulators in orthognathic surgery. Am J Orthod Dentofacial Orthop 1986: 90: 37-44.
    • (1986) Am J Orthod Dentofacial Orthop , vol.90 , pp. 37-44
    • Marko, J.V.1
  • 12
    • 0040097608 scopus 로고
    • Fundamentals involved in prescribing restorative dental remedies
    • MCCOLLUM BB. Fundamentals involved in prescribing restorative dental remedies. Dent Items Interest 1939: 61: 522-35.
    • (1939) Dent Items Interest , vol.61 , pp. 522-535
    • Mccollum, B.B.1
  • 13
    • 0026018201 scopus 로고
    • The significance of an erroneous recording of the centre of mandibular rotation in orthognathic surgery
    • NATTESTAD A, VEDTOFTE P, MOSEKILDE E. The significance of an erroneous recording of the centre of mandibular rotation in orthognathic surgery. J Cranio-Max-Fac Surg 1991: 19: 254-9.
    • (1991) J Cranio-Max-Fac Surg , vol.19 , pp. 254-259
    • Nattestad, A.1    Vedtofte, P.2    Mosekilde, E.3
  • 16
    • 0040097611 scopus 로고
    • A study of the arbitrary centre and the kinematic centre of rotation for face-bow mountings
    • SCHALLHORN RG. A study of the arbitrary centre and the kinematic centre of rotation for face-bow mountings. J Prosthet Dent 1957: 7: 162-9.
    • (1957) J Prosthet Dent , vol.7 , pp. 162-169
    • Schallhorn, R.G.1
  • 17
    • 0039505813 scopus 로고
    • Articulation
    • SNOW GB. Articulation. Dent Cosmos 1900: 42: 531-5.
    • (1900) Dent Cosmos , vol.42 , pp. 531-535
    • Snow, G.B.1
  • 18
    • 0018987285 scopus 로고
    • Discrepancies between arbitrary and true hinge axis
    • WALKER PM. Discrepancies between arbitrary and true hinge axis. J Prosthet Dent 1980: 43: 279-85.
    • (1980) J Prosthet Dent , vol.43 , pp. 279-285
    • Walker, P.M.1
  • 19
    • 0020754356 scopus 로고
    • Comparison of a universal mounting jig to a face-bow
    • YANUS M, FINGER IM, WEINBERG R. Comparison of a universal mounting jig to a face-bow. J Prosthet Dent 1983: 49: 623-7.
    • (1983) J Prosthet Dent , vol.49 , pp. 623-627
    • Yanus, M.1    Finger, I.M.2    Weinberg, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.