메뉴 건너뛰기




Volumn 18, Issue 6, 1996, Pages 495-501

A new in vitro measurement technique for small three-dimensional joint motion and its application to the sacroiliac joint

Author keywords

3 D joint motion; In vitro measurement; Rigid body kinematics; Sacroiliac joint

Indexed keywords

COMPUTER APPLICATIONS; DEGREES OF FREEDOM (MECHANICS); ELECTRIC TRANSFORMERS; ELECTROMECHANICAL DEVICES; JOINTS (ANATOMY); KINEMATICS; PHOTOGRAMMETRY; POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); THREE DIMENSIONAL;

EID: 0030250948     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/1350-4533(95)00078-X     Document Type: Article
Times cited : (6)

References (8)
  • 1
    • 0019493755 scopus 로고
    • A technique for measurement and description of three-dimensional six degree-of-freedom motion of a body joint with an application to the human spine
    • 1. Panjabi MM, Krag MH, Goel VK. A technique for measurement and description of three-dimensional six degree-of-freedom motion of a body joint with an application to the human spine. J Biomech 1981; 14: 447-60.
    • (1981) J Biomech , vol.14 , pp. 447-460
    • Panjabi, M.M.1    Krag, M.H.2    Goel, V.K.3
  • 3
    • 0019159246 scopus 로고
    • Justification of triaxial goniometer for the measurement of joint rotation
    • 3. Chao EYS. Justification of triaxial goniometer for the measurement of joint rotation. J Biomech 1980; 13: 989-1006.
    • (1980) J Biomech , vol.13 , pp. 989-1006
    • Chao, E.Y.S.1
  • 4
    • 0002242532 scopus 로고
    • Roentgen stereogrammetry: A method for the study of the kinematics of the skeleton system
    • 4. Selvik G. Roentgen stereogrammetry: a method for the study of the kinematics of the skeleton system. Acta Orthop Scand 1989; Suppl. 232.
    • (1989) Acta Orthop Scand , Issue.SUPPL. , pp. 232
    • Selvik, G.1
  • 5
    • 0026552157 scopus 로고
    • Rationalization of kinematic descriptors for three-dimensional hand and finger motion
    • 5. Small CF, Bryant JT, Pichora DR. Rationalization of kinematic descriptors for three-dimensional hand and finger motion. J Biomed Eng 1992; 14: 133-41.
    • (1992) J Biomed Eng , vol.14 , pp. 133-141
    • Small, C.F.1    Bryant, J.T.2    Pichora, D.R.3
  • 6
    • 0018251634 scopus 로고
    • Movements in the sacroiliac joints demonstrated with roentgen stereophotogrammetry
    • 6. Egund N, Olsson TH, Schmid H, Selvik G. Movements in the sacroiliac joints demonstrated with roentgen stereophotogrammetry. Radiologica Diagnosis 1978; 19: 833-46.
    • (1978) Radiologica Diagnosis , vol.19 , pp. 833-846
    • Egund, N.1    Olsson, T.H.2    Schmid, H.3    Selvik, G.4
  • 7
    • 0024507725 scopus 로고
    • Movements of the sacroiliac joints: A roentgen stereophotogrammetric analysis
    • 7. Sturesson B, Selvik G, Uden A. Movements of the sacroiliac joints: a roentgen stereophotogrammetric analysis. Spine 1989; 14: 162-5.
    • (1989) Spine , vol.14 , pp. 162-165
    • Sturesson, B.1    Selvik, G.2    Uden, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.