메뉴 건너뛰기




Volumn 42, Issue 5, 1996, Pages

Transluminal aortic valve placement: A feasibility study with a newly designed collapsible aortic valve

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSEL PROSTHESES; CARDIOVASCULAR SYSTEM; CATHETERS; ECHOCARDIOGRAPHY; HEMODYNAMICS; MODELS; STAINLESS STEEL;

EID: 0030250460     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002480-199609000-00016     Document Type: Article
Times cited : (32)

References (12)
  • 1
    • 0028917508 scopus 로고
    • Endovascular repair of abdominal aortic aneurysms and other arterial lesions
    • Parodi JC: Endovascular repair of abdominal aortic aneurysms and other arterial lesions. J Vasc Surg 21: 549-557, 1995.
    • (1995) J Vasc Surg , vol.21 , pp. 549-557
    • Parodi, J.C.1
  • 2
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fischman DL, Leon MB, Baim DS, et al: A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med 331: 496-501, 1994.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 3
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys PW, Jaegere P, Kiemeneij F, et al: A comparison of balloon-expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med 331: 489-495, 1994.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    Jaegere, P.2    Kiemeneij, F.3
  • 4
    • 0027166255 scopus 로고
    • Transfemoral endovascular aortic graft placement
    • Chuter TAM, Green RM, Ouriel K, et al: Transfemoral endovascular aortic graft placement. J Vasc Surg 18: 185-197, 1993.
    • (1993) J Vasc Surg , vol.18 , pp. 185-197
    • Chuter, T.A.M.1    Green, R.M.2    Ouriel, K.3
  • 5
    • 0028436722 scopus 로고
    • Stabilization of pericardial tissue by dye-mediated photooxidation
    • Moore MA, Bohachevsky IK, Cheung DT, et al: Stabilization of pericardial tissue by dye-mediated photooxidation. J Biomed Mater Res 28: 611-618, 1994.
    • (1994) J Biomed Mater Res , vol.28 , pp. 611-618
    • Moore, M.A.1    Bohachevsky, I.K.2    Cheung, D.T.3
  • 6
    • 0019799237 scopus 로고
    • Design and evaluation of the Pennsylvania State University Mock Circulatory System
    • Rosenberg G, Phillips WM, Landis DL, Pierce WS: Design and evaluation of the Pennsylvania State University Mock Circulatory System. ASAIO J 4(2): 41-49, 1981.
    • (1981) ASAIO J , vol.4 , Issue.2 , pp. 41-49
    • Rosenberg, G.1    Phillips, W.M.2    Landis, D.L.3    Pierce, W.S.4
  • 7
    • 0026580610 scopus 로고
    • Development and initial experimental evaluation of a prosthetic aortic valve for transcatheter placement
    • Pavcnik D, Wright KC, Wallace S: Development and initial experimental evaluation of a prosthetic aortic valve for transcatheter placement. Radiology 183: 151-154, 1992.
    • (1992) Radiology , vol.183 , pp. 151-154
    • Pavcnik, D.1    Wright, K.C.2    Wallace, S.3
  • 8
    • 0026562077 scopus 로고
    • Transluminal implantation of artificial heart valves: Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs
    • Andersen HR, Knudsen LL, Hasenkam JM: Transluminal implantation of artificial heart valves: description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs. Eur Heart J 13: 704-708, 1992.
    • (1992) Eur Heart J , vol.13 , pp. 704-708
    • Andersen, H.R.1    Knudsen, L.L.2    Hasenkam, J.M.3
  • 11
    • 0019958809 scopus 로고
    • In vitro evaluation of prosthetic heart valves: Anomalies and limitations
    • Tindale WB, Black MM, Martin TR: In vitro evaluation of prosthetic heart valves: anomalies and limitations, Clin Phys Physiol Meas 3: 115-130, 1982.
    • (1982) Clin Phys Physiol Meas , vol.3 , pp. 115-130
    • Tindale, W.B.1    Black, M.M.2    Martin, T.R.3
  • 12
    • 10244221296 scopus 로고
    • Choice of mechanical aortic prosthetic valve
    • Emery RW, Arom KV (eds), Philadelphia, Hanley & Belfus
    • Arom KV: Choice of mechanical aortic prosthetic valve, in Emery RW, Arom KV (eds), The Aortic Valve, Philadelphia, Hanley & Belfus, 1991, pp. 187-201.
    • (1991) The Aortic Valve , pp. 187-201
    • Arom, K.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.