Volumn 5, Issue 3, 1996, Pages 166-179

A hermetic glass-silicon micropackage with high-density on-chip feedthroughs for sensors and actuators

Author keywords

[No Author keywords available]

Indexed keywords

ACTUATORS; BONDING; CAPACITORS; ELECTRONIC PROPERTIES; GLASS; LOW TEMPERATURE OPERATIONS; RELIABILITY; SEMICONDUCTING SILICON; SEMICONDUCTOR DEVICE MANUFACTURE; SENSORS;

EID: 0030246136     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/84.536623     Document Type: Article
Times cited : (112)

References (34)
  • 2
    • 0028670785 scopus 로고
    • The challenges for hermetic encapsulation of implanted devices - A review
    • M. F. Nichols, "The challenges for hermetic encapsulation of implanted devices - A review," Critical Review in Biomedical Engineering, vol. 22, no. 1, pp. 39-67, 1994.
    • (1994) Critical Review in Biomedical Engineering , vol.22 , Issue.1 , pp. 39-67
    • Nichols, M.F.1
  • 3
    • 0022559401 scopus 로고
    • The packaging of implantable integrated sensors
    • Feb.
    • L. Bowman, and J. Meindl, "The packaging of implantable integrated sensors," IEEE Trans. Biomed. Eng., vol. BME-33, no. 2, pp. 248-255, Feb. 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.BME-33 , Issue.2 , pp. 248-255
    • Bowman, L.1    Meindl, J.2
  • 5
    • 0020456136 scopus 로고
    • Polyether polyurethanes for implantable pacemaker leads
    • K. Stokes, and K. Cobian, "Polyether polyurethanes for implantable pacemaker leads," Biomaterials, vol. 3, pp. 225-231, 1982.
    • (1982) Biomaterials , vol.3 , pp. 225-231
    • Stokes, K.1    Cobian, K.2
  • 6
    • 0017368305 scopus 로고
    • Parylene C as a chronically stable, reproducible microelectrode insulator
    • Mar.
    • G. E. Loeb, M. J. Bak, M. Salcman, and E. M. Schmidt, "Parylene C as a chronically stable, reproducible microelectrode insulator," IEEE Trans. Biomed. Eng., vol. BME-24, pp. 121-128, Mar. 1977.
    • (1977) IEEE Trans. Biomed. Eng. , vol.BME-24 , pp. 121-128
    • Loeb, G.E.1    Bak, M.J.2    Salcman, M.3    Schmidt, E.M.4
  • 7
    • 0020715238 scopus 로고
    • Packaging materials and techniques for implantable instruments
    • Mar.
    • W. H. Ko and T. M. Spears, "Packaging materials and techniques for implantable instruments," Eng. Med. Biol, vol. 2, pp. 24-38, Mar. 1983.
    • (1983) Eng. Med. Biol , vol.2 , pp. 24-38
    • Ko, W.H.1    Spears, T.M.2
  • 8
    • 0015089338 scopus 로고
    • Thin films of glass and their application to biomedical sensors
    • July
    • K. D. Wise and R. H. Weisman, "Thin films of glass and their application to biomedical sensors," Med. Biol. Eng., vol. 9, pp. 339-350, July 1971.
    • (1971) Med. Biol. Eng. , vol.9 , pp. 339-350
    • Wise, K.D.1    Weisman, R.H.2
  • 10
    • 0014563672 scopus 로고
    • Field-assisted glass-metal sealing
    • Sept.
    • G. Wallis, and D. Pomerantz, "Field-assisted glass-metal sealing," J. Appl. Phys., vol. 40, pp. 3946-3949, Sept. 1969.
    • (1969) J. Appl. Phys. , vol.40 , pp. 3946-3949
    • Wallis, G.1    Pomerantz, D.2
  • 11
    • 0023331380 scopus 로고
    • A technology for high-performance single-crystal silicon-on-insulator transistors
    • Apr.
    • L. J. Spangler, and K. D. Wise, "A technology for high-performance single-crystal silicon-on-insulator transistors," IEEE Electron Device Lett., vol. EDL-8, no. 4, pp. 137-139, Apr. 1987.
    • (1987) IEEE Electron Device Lett. , vol.EDL-8 , Issue.4 , pp. 137-139
    • Spangler, L.J.1    Wise, K.D.2
  • 13
    • 0025546385 scopus 로고
    • RF telemetry powering and control of hermetically sealed integrated sensors and actuators
    • Hilton Head, SC, June
    • T. Akin, B. Ziaie, and K. Najafi, "RF telemetry powering and control of hermetically sealed integrated sensors and actuators," in Tech. Dig., IEEE Solid-State Sensors and Actuators Workshop, Hilton Head, SC, June 1990, pp. 145-148,
    • (1990) Tech. Dig., IEEE Solid-State Sensors and Actuators Workshop , pp. 145-148
    • Akin, T.1    Ziaie, B.2    Najafi, K.3
  • 14
    • 0042854679 scopus 로고
    • A Single Channel implantable microstimulator for functional neuromuscular stimulation
    • Yokohama, Japan, June
    • B. Ziaie, M. Nardin, J. Von Arx, and K. Najafi, "A Single Channel implantable microstimulator for functional neuromuscular stimulation," in Proc. 7th Int. Conf. Solid State Sensors & Actuators, Yokohama, Japan, June 1993, pp. 450-453.
    • (1993) Proc. 7th Int. Conf. Solid State Sensors & Actuators , pp. 450-453
    • Ziaie, B.1    Nardin, M.2    Von Arx, J.3    Najafi, K.4
  • 18
    • 0001494663 scopus 로고
    • Dielectric and polysilicon film deposition
    • S. M. Sze, Ed. New York: McGraw-Hill
    • A. C. Adams, "Dielectric and polysilicon film deposition," in VLSI Technology, S. M. Sze, Ed. New York: McGraw-Hill, 1988.
    • (1988) VLSI Technology
    • Adams, A.C.1
  • 20
    • 0024767646 scopus 로고
    • Fabrication of micromechanical devices from polysilicon films with smooth surfaces
    • Nov.
    • H. Guckel, J. J. Sniegowski, and T. R. Christenson, "Fabrication of micromechanical devices from polysilicon films with smooth surfaces," Sensors and Actuators, vol. 20, nos. 1/2, pp. 117-122, Nov. 1989.
    • (1989) Sensors and Actuators , vol.20 , Issue.1-2 , pp. 117-122
    • Guckel, H.1    Sniegowski, J.J.2    Christenson, T.R.3
  • 21
    • 0343523769 scopus 로고
    • A hermetic packaging technology with multiple feedthroughs for integrated sensors and actuators
    • Yokohama, Japan, June
    • B. Ziaie, J. Von Arx, M. Nardin, and K. Najafi, "A hermetic packaging technology with multiple feedthroughs for integrated sensors and actuators," in Proc. 7th Int. Conf. Solid State Sensors & Actuators, Yokohama, Japan, June 1993, pp. 266-269.
    • (1993) Proc. 7th Int. Conf. Solid State Sensors & Actuators , pp. 266-269
    • Ziaie, B.1    Von Arx, J.2    Nardin, M.3    Najafi, K.4
  • 22
    • 0026157904 scopus 로고
    • Phosphorus doped polysilicon for double poly structures I - Morphology and microstructure
    • May
    • M. Hendriks, and C. Mavero, "Phosphorus doped polysilicon for double poly structures I - Morphology and microstructure," J. Electrochem. Soc., vol. 138, no. 5, pp. 1466-1470, May 1991.
    • (1991) J. Electrochem. Soc. , vol.138 , Issue.5 , pp. 1466-1470
    • Hendriks, M.1    Mavero, C.2
  • 23
    • 0022818086 scopus 로고
    • Growth kinematics of a polysilicon trench refill process
    • Nov.
    • V. J. Silvestri, "Growth kinematics of a polysilicon trench refill process," J. Electrochem. Soc., vol. 133, no. 11, pp. 2374-2376, Nov. 1986.
    • (1986) J. Electrochem. Soc. , vol.133 , Issue.11 , pp. 2374-2376
    • Silvestri, V.J.1
  • 24
    • 0025359786 scopus 로고
    • Scaling limitations of silicon multichannel recording probes
    • Jan.
    • K. Najafi, J. Ji, and K. D. Wise, "Scaling limitations of silicon multichannel recording probes," IEEE Trans. Biomed. Eng., vol. 37, pp. 1-11, Jan. 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 1-11
    • Najafi, K.1    Ji, J.2    Wise, K.D.3
  • 25
    • 0022559398 scopus 로고
    • Thin-film multiple electrode probes: Possibilities and limitations
    • Feb.
    • O. J. Prohaska, F. Olcaytug, P. Pfundner, and H. Dragaun, "Thin-film multiple electrode probes: possibilities and limitations," IEEE Trans. Biomed. Eng., vol. BME-33, pp. 223-229, Feb. 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.BME-33 , pp. 223-229
    • Prohaska, O.J.1    Olcaytug, F.2    Pfundner, P.3    Dragaun, H.4
  • 26
  • 27
    • 0038790514 scopus 로고
    • Package Sealing and Encapsulation
    • R. R. Tummala and E. J. Rymaszewski, Eds. New York: Van Nostrand Reinhold
    • A. H. Kumar, and B. Ozmat, "Package Sealing and Encapsulation," in Microelectronics Packaging Handbook, R. R. Tummala and E. J. Rymaszewski, Eds. New York: Van Nostrand Reinhold, 1989.
    • (1989) Microelectronics Packaging Handbook
    • Kumar, A.H.1    Ozmat, B.2
  • 28
    • 0024683439 scopus 로고
    • Diffusion of water into a borosilicate glass
    • H. Tomozawa and M. Tomozawa, "Diffusion of water into a borosilicate glass," J. Non-Crystalline Solids, vol. 109, pp. 311-317, 1989.
    • (1989) J. Non-Crystalline Solids , vol.109 , pp. 311-317
    • Tomozawa, H.1    Tomozawa, M.2
  • 32
    • 5844398851 scopus 로고
    • Package reliability
    • R. R. Tummala and E. J. Rymaszewski, Eds. New York: Van Nostrand Reinhold
    • D. A. Jeannotte, L. S. Goldmann, and R. T. Howard, "Package reliability" in Microelectronics Packaging Handbook, R. R. Tummala and E. J. Rymaszewski, Eds. New York: Van Nostrand Reinhold, 1989.
    • (1989) Microelectronics Packaging Handbook
    • Jeannotte, D.A.1    Goldmann, L.S.2    Howard, R.T.3
  • 34
    • 0028416752 scopus 로고
    • Silicon ribbon cables for chronically implantable microelectrode arrays
    • Apr.
    • J. F. Hetke, J. L. Lund, K. Najafi, D. Wise, and D. J. Anderson, "Silicon ribbon cables for chronically implantable microelectrode arrays" IEEE Trans. Biomed. Eng. vol. 41, no. 4, pp. 314-321, Apr. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , Issue.4 , pp. 314-321
    • Hetke, J.F.1    Lund, J.L.2    Najafi, K.3    Wise, D.4    Anderson, D.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.