메뉴 건너뛰기




Volumn 100, Issue 5, 1996, Pages 375-383

Motor evoked potential monitoring during spinal surgery: Responses of distal limb muscles to transcranial cortical stimulation with pulse trains

Author keywords

Motor evoked potentials; Peroperative monitoring; Propofol anaesthesia; Spinal surgery; Transcranial cortical stimulation

Indexed keywords

ALFENTANIL; MIDAZOLAM; NITROUS OXIDE; PROPOFOL;

EID: 0030245683     PISSN: 01685597     EISSN: None     Source Type: Journal    
DOI: 10.1016/0168-5597(96)95728-7     Document Type: Article
Times cited : (193)

References (36)
  • 1
    • 0021802893 scopus 로고
    • Non-invasive magnetic stimulation of the human motor cortex
    • Barker, A.T., Jalinous, R. and Freeston, I.L. Non-invasive magnetic stimulation of the human motor cortex. Lancet, 1985, 1: 1106-1107.
    • (1985) Lancet , vol.1 , pp. 1106-1107
    • Barker, A.T.1    Jalinous, R.2    Freeston, I.L.3
  • 3
    • 0027081498 scopus 로고
    • Assessment of corticospinal and somatosensory conduction simultaneously during scoliosis surgery
    • Burke, D., Hicks, R., Stephen, J., Woodforth, I. and Crawford, M. Assessment of corticospinal and somatosensory conduction simultaneously during scoliosis surgery. Electroenceph. clin. Neurophysiol., 1992, 85: 388-396.
    • (1992) Electroenceph. Clin. Neurophysiol. , vol.85 , pp. 388-396
    • Burke, D.1    Hicks, R.2    Stephen, J.3    Woodforth, I.4    Crawford, M.5
  • 4
    • 0011763974 scopus 로고
    • New evidence on corticospinal tract behavior after repetitive stimulation of the motor cortex
    • Deletis, V., Isgum, V. and Rodi, Z. New evidence on corticospinal tract behavior after repetitive stimulation of the motor cortex. Electroenceph. clin. Neurophysiol., 1995, 97: S195-S196.
    • (1995) Electroenceph. Clin. Neurophysiol. , vol.97
    • Deletis, V.1    Isgum, V.2    Rodi, Z.3
  • 5
    • 0024409199 scopus 로고
    • Transcranial motor evoked potentials (tcMMEP) for functional monitoring of motor pathways during scoliosis surgery
    • Edmonds, H.L., Paloheimo, M.P.J., Backman, M.H., Johnson, J.R., Holt, R.T. and Shields, C.B. Transcranial motor evoked potentials (tcMMEP) for functional monitoring of motor pathways during scoliosis surgery. Spine, 1989, 14: 683-686.
    • (1989) Spine , vol.14 , pp. 683-686
    • Edmonds, H.L.1    Paloheimo, M.P.J.2    Backman, M.H.3    Johnson, J.R.4    Holt, R.T.5    Shields, C.B.6
  • 7
    • 0011760534 scopus 로고
    • Defining reliable anaesthetic protocols for intraoperative monitoring of transcranial magnetic evoked potentials
    • S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.). Kluwer, Dordrecht
    • Fraser, M.H., Soni, B, Noble, G., Watt, J.H., Clay, R. and Krishnan, K.R. Defining reliable anaesthetic protocols for intraoperative monitoring of transcranial magnetic evoked potentials. In: S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.), Handbook of Spinal Cord Monitoring. Kluwer, Dordrecht, 1994, pp. 281-285.
    • (1994) Handbook of Spinal Cord Monitoring , pp. 281-285
    • Fraser, M.H.1    Soni, B.2    Noble, G.3    Watt, J.H.4    Clay, R.5    Krishnan, K.R.6
  • 8
    • 0025294710 scopus 로고
    • Depressive effect of isoflurane anesthesia on motor evoked potentials
    • Haghighi, S.S., Green, K.D., Oro, J.J., Drake, R.K. and Kracke, G.R. Depressive effect of isoflurane anesthesia on motor evoked potentials. Neurosurgery, 1990, 26: 993-997.
    • (1990) Neurosurgery , vol.26 , pp. 993-997
    • Haghighi, S.S.1    Green, K.D.2    Oro, J.J.3    Drake, R.K.4    Kracke, G.R.5
  • 9
    • 33751428086 scopus 로고
    • Transcranial magnetic stimulation for spinal cord monitoring
    • S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.). Kluwer, Dordrecht
    • Herdmann, J., Krzan, M., Sonnenschein, F. and Lumenta, C.B. Transcranial magnetic stimulation for spinal cord monitoring. In: S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.), Handbook of Spinal Cord Monitoring. Kluwer, Dordrecht, 1994, pp. 286-293.
    • (1994) Handbook of Spinal Cord Monitoring , pp. 286-293
    • Herdmann, J.1    Krzan, M.2    Sonnenschein, F.3    Lumenta, C.B.4
  • 12
    • 0026001521 scopus 로고
    • Non-invasive intraoperative monitoring of motor evoked potentials under propofol anesthesia: Effects of spinal surgery on the amplitude and latency of motor evoked potentials
    • Jellinek, D., Jewkes, D. and Symon, L. Non-invasive intraoperative monitoring of motor evoked potentials under propofol anesthesia: effects of spinal surgery on the amplitude and latency of motor evoked potentials. Neurosurgery, 1991a, 29: 551-557.
    • (1991) Neurosurgery , vol.29 , pp. 551-557
    • Jellinek, D.1    Jewkes, D.2    Symon, L.3
  • 13
    • 0025953411 scopus 로고
    • Effects of nitrous oxide on motor evoked potentials recorded from skeletal muscle in patients under total anesthesia with intravenously administered propofol
    • Jellinek, D., Platt, M., Jewkes, D. and Symon, L. Effects of nitrous oxide on motor evoked potentials recorded from skeletal muscle in patients under total anesthesia with intravenously administered propofol. Neurosurgery, 1991b, 29: 558-562.
    • (1991) Neurosurgery , vol.29 , pp. 558-562
    • Jellinek, D.1    Platt, M.2    Jewkes, D.3    Symon, L.4
  • 14
    • 0011779181 scopus 로고
    • Ketamine anaesthesia allows recording of muscle responses to magnetic cortical stimulation: An electrophysiological study in man
    • S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.). Kluwer, Dordrecht
    • Kothbauer, K., Schmid, U.D., Leichti, S. and Rösler, K.M. Ketamine anaesthesia allows recording of muscle responses to magnetic cortical stimulation: an electrophysiological study in man. In: S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.), Handbook of Spinal Cord Monitoring. Kluwer, Dordrecht, 1994, pp. 327-333.
    • (1994) Handbook of Spinal Cord Monitoring , pp. 327-333
    • Kothbauer, K.1    Schmid, U.D.2    Leichti, S.3    Rösler, K.M.4
  • 15
    • 0022655150 scopus 로고
    • Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentials
    • Lesser, R.P., Raudzens, P., Lueders, H. et al. Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentials. Ann. Neurol., 1986, 19: 22-25.
    • (1986) Ann. Neurol. , vol.19 , pp. 22-25
    • Lesser, R.P.1    Raudzens, P.2    Lueders, H.3
  • 16
    • 0023173032 scopus 로고
    • Clinical experience with motor and cerebellar evoked potential monitoring
    • Levy, W.J. Clinical experience with motor and cerebellar evoked potential monitoring. Neurosurgery, 1987, 20: 169-182.
    • (1987) Neurosurgery , vol.20 , pp. 169-182
    • Levy, W.J.1
  • 17
    • 0019991843 scopus 로고
    • Scope of a technique for electrical stimulation of the human brain, spinal cord and muscle
    • Merton, P.A., Morton, H.B., Hill, D.K. and Marsden, C.D. Scope of a technique for electrical stimulation of the human brain, spinal cord and muscle. Lancet, 1982, 2: 597-600.
    • (1982) Lancet , vol.2 , pp. 597-600
    • Merton, P.A.1    Morton, H.B.2    Hill, D.K.3    Marsden, C.D.4
  • 19
    • 0028881660 scopus 로고
    • Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter survey
    • Nuwer, M.R., Dawson, E.G., Carlson, L.G., Kanim, L.E.A. and Sherman, J.E. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroenceph. clin, Neurophysiol., 1995, 96: 6-11.
    • (1995) Electroenceph. Clin, Neurophysiol. , vol.96 , pp. 6-11
    • Nuwer, M.R.1    Dawson, E.G.2    Carlson, L.G.3    Kanim, L.E.A.4    Sherman, J.E.5
  • 20
    • 0025081283 scopus 로고
    • Relationship among level of distraction, evoked potentials, spinal cord ischaemia and integrity, and clinical status in animals
    • Owen, J.H., Naito, M. and Bridwell, K.H. Relationship among level of distraction, evoked potentials, spinal cord ischaemia and integrity, and clinical status in animals. Spine, 1990, 15: 852-857.
    • (1990) Spine , vol.15 , pp. 852-857
    • Owen, J.H.1    Naito, M.2    Bridwell, K.H.3
  • 21
    • 0011768766 scopus 로고
    • Recording of myogenic motor evoked potentials (mMEP) under general anaesthesia using a train of transcranial electric stimuli
    • S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.). Kluwer, Dordrecht
    • Pechstein, U., Taniguchi, M., Nadstawek, J. and Schramm, J. Recording of myogenic motor evoked potentials (mMEP) under general anaesthesia using a train of transcranial electric stimuli. In: S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.), Handbook of Spinal Cord Monitoring. Kluwer, Dordrecht, 1994, pp. 346-352.
    • (1994) Handbook of Spinal Cord Monitoring , pp. 346-352
    • Pechstein, U.1    Taniguchi, M.2    Nadstawek, J.3    Schramm, J.4
  • 22
    • 0029059153 scopus 로고
    • Motor evoked potentials induced by electrical stimulation of the spine in dogs: Which structures are involved?
    • Poncelet, L., Michaux, C. and Balligand, M. Motor evoked potentials induced by electrical stimulation of the spine in dogs: which structures are involved? Electroenceph. clin. Neurophysiol., 1995, 97: 179-183.
    • (1995) Electroenceph. Clin. Neurophysiol. , vol.97 , pp. 179-183
    • Poncelet, L.1    Michaux, C.2    Balligand, M.3
  • 23
    • 0029876446 scopus 로고    scopus 로고
    • Neurophysiological aspects of motor evoked potentials elicited by trains of stimuli
    • Rodi, Z., Deletis, V., Morota, N. and Vodusek, D.B. Neurophysiological aspects of motor evoked potentials elicited by trains of stimuli. Pflügers Arch. Eur. J. Physiol., 1996, 431: R291-R292.
    • (1996) Pflügers Arch. Eur. J. Physiol. , vol.431
    • Rodi, Z.1    Deletis, V.2    Morota, N.3    Vodusek, D.B.4
  • 24
    • 0022260488 scopus 로고
    • Nervous propagation along 'central' motor pathways in intact man: Characteristics of motor responses to 'bifocal' and 'unifocal' spine or scalp non-invasive stimulation
    • Rossini, P.M., Marciani, M.G., Caramia, M., Roma, V. and Zarola, F. Nervous propagation along 'central' motor pathways in intact man: characteristics of motor responses to 'bifocal' and 'unifocal' spine or scalp non-invasive stimulation. Electroenceph. clin. Neurophysiol., 1985, 61: 272-286.
    • (1985) Electroenceph. Clin. Neurophysiol. , vol.61 , pp. 272-286
    • Rossini, P.M.1    Marciani, M.G.2    Caramia, M.3    Roma, V.4    Zarola, F.5
  • 25
    • 0027374084 scopus 로고
    • Awareness during total intravenous anaesthesia
    • Sandrin, R. and Nordstrom, O. Awareness during total intravenous anaesthesia. Br. J. Anaesth., 1993, 71: 782-787.
    • (1993) Br. J. Anaesth. , vol.71 , pp. 782-787
    • Sandrin, R.1    Nordstrom, O.2
  • 26
    • 0026514032 scopus 로고
    • Influence of some anesthetic agents on muscle responses to transcranial magnetic cortex stimulation: A pilot study in humans
    • Schmid, U.D., Boll, J., Leichti, S., Schmid, J. and Hess, C.W. Influence of some anesthetic agents on muscle responses to transcranial magnetic cortex stimulation: a pilot study in humans. Neurosurgery, 1992, 30: 85-92.
    • (1992) Neurosurgery , vol.30 , pp. 85-92
    • Schmid, U.D.1    Boll, J.2    Leichti, S.3    Schmid, J.4    Hess, C.W.5
  • 29
    • 0027457646 scopus 로고
    • Temporal summation: The key to motor evoked potential spinal cord monitoring in humans
    • Taylor, B.A., Fennelly, M.E., Taylor, A. and Farrell, J. Temporal summation: the key to motor evoked potential spinal cord monitoring in humans. J. Neurol. Neurosurg, Psychiatry, 1994a, 56: 104-106.
    • (1994) J. Neurol. Neurosurg, Psychiatry , vol.56 , pp. 104-106
    • Taylor, B.A.1    Fennelly, M.E.2    Taylor, A.3    Farrell, J.4
  • 30
    • 0011768767 scopus 로고
    • Near maximal transcranial magnetic motor evoked potentials during surgery
    • S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.). Kluwer, Dordrecht
    • Taylor, B.A., Fennelly, M.E., Morley, T.R., Hetreed, M. and Farrell, J. Near maximal transcranial magnetic motor evoked potentials during surgery. In: S.J. Jones, S. Boyd, M. Hetreed and N.J. Smith (Eds.), Handbook of Spinal Cord Monitoring. Kluwer, Dordrecht, 1994b, pp. 376-382.
    • (1994) Handbook of Spinal Cord Monitoring , pp. 376-382
    • Taylor, B.A.1    Fennelly, M.E.2    Morley, T.R.3    Hetreed, M.4    Farrell, J.5
  • 31
    • 0025904904 scopus 로고
    • Percutaneous electrical stimulation of corticospinal pathways at the level of the pyramidal decussation in humans
    • Ugawa, Y., Rothwell, J.C., Day, B.L., Thompson, P.D. and Marsden, C.D. Percutaneous electrical stimulation of corticospinal pathways at the level of the pyramidal decussation in humans. Ann. Neurol., 1991, 29: 418-427.
    • (1991) Ann. Neurol. , vol.29 , pp. 418-427
    • Ugawa, Y.1    Rothwell, J.C.2    Day, B.L.3    Thompson, P.D.4    Marsden, C.D.5
  • 32
    • 0015845886 scopus 로고
    • Functional monitoring of spinal cord activity during spinal surgery
    • Vauzelle, C., Stagnara, P. and Jouvinroux, P. Functional monitoring of spinal cord activity during spinal surgery. Clin. Orthop. Relat. Res., 1973, 93: 173-178.
    • (1973) Clin. Orthop. Relat. Res. , vol.93 , pp. 173-178
    • Vauzelle, C.1    Stagnara, P.2    Jouvinroux, P.3
  • 33
    • 0024573460 scopus 로고
    • Noninvasive motor evoked potential monitoring during neurosurgical operations on the spinal cord
    • Zentner, J. Noninvasive motor evoked potential monitoring during neurosurgical operations on the spinal cord. Neurosurgery, 1989, 24: 709-712.
    • (1989) Neurosurgery , vol.24 , pp. 709-712
    • Zentner, J.1
  • 34
    • 0025968403 scopus 로고
    • Motor evoked potential monitoring during neurosurgical operations on the spinal cord
    • Zentner, J. Motor evoked potential monitoring during neurosurgical operations on the spinal cord. Neurosurg. Rev., 1991, 14: 29-36.
    • (1991) Neurosurg. Rev. , vol.14 , pp. 29-36
    • Zentner, J.1
  • 35
    • 0024531852 scopus 로고
    • Nitrous oxide suppresses the electromyographic response evoked by electrical stimulation of the motor cortex
    • Zentner, J. and Ebner, A. Nitrous oxide suppresses the electromyographic response evoked by electrical stimulation of the motor cortex. Neurosurgery, 1989, 24: 60-62.
    • (1989) Neurosurgery , vol.24 , pp. 60-62
    • Zentner, J.1    Ebner, A.2
  • 36
    • 0024537860 scopus 로고
    • Influence of anesthetics - Nitrous oxide in particular - On electromyographic response evoked by transcranial electrical stimulation of the cortex
    • Zentner, J., Kiss, I. and Ebner, A. Influence of anesthetics - nitrous oxide in particular - on electromyographic response evoked by transcranial electrical stimulation of the cortex. Neurosurgery, 1989, 24: 253-256.
    • (1989) Neurosurgery , vol.24 , pp. 253-256
    • Zentner, J.1    Kiss, I.2    Ebner, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.